ENERGIZER CR1216 - Energizer Technical Information

PRODUCT DATASHEET
1-800-383-7323
/ USA USA/CAN
1-800-383-7323
1-800-383-7323
/ CANADA
www.energizer.com
ENERGIZER CR1216
Lithium Coin
Specifications
Classification:
Chemical System:
Designation:
Nominal Voltage:
Typical Capacity:
Industry Standard Dimensions
mm (inches)
This Battery has Underwriters
Laboratories component Recognition
"Lithium Coin"
Lithium / Manganese Dioxide (Li/MnO2)
ANSI-5034LC, IEC-CR1216
3.0 Volts
34 mAh (to 2.0 volts)
(Rated at 62K ohms at 21°C)
0.6 grams (0.02 oz.)
0.2 cubic centimeters (0.01 cubic inch)
1 microampere
118 milliwatt hr/g, 413 milliwatt hr/cc
0.008 grams (0.0003 oz.)
MH29980
-30C to 70C
~1% / year
Typical Weight:
Typical Volume:
Max Rev Charge:
Energy Density:
Typical Li Content:
UL Recognized:
Operating Temp:
Self Discharge:
12.50 (0.492)
12.20 (0.480)
1.40 (0.055)
1.40 (0.055) Ref.
4.00 (0.157)
Minimum
(1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to
serious injury or death in as little as 2 hours due to chemical burns and
potential perforation of the esophagus. Immediately see doctor; have
doctor phone (202) 625-3333.
1.10 (0.043) Ref.
0.30 (0.012) Maximum Ref.
Permissible deflection from a flat.
0.03 (0.001) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
Simulated Application test
Typical Performance at 21°C (70°F)
Schedule:
Typical Drains:
at 2.85V
(mA)
(ohms)
Cutoff
2.0V
(hours)
0.046
62,000
739
Continuous
Safety:
Load
(2) Battery compartment design. To prevent children from removing
batteries, battery compartments should be designed with one of the
following methods: a) a tool such as screwdriver or coin is required to open
battery compartment or b) the battery compartment door/cover requires
the application of a minimum of two independent and simultaneous
movements of the securing mechanism to open by hand. Screws should
remain captive with the battery door or cover.
Internal Resistance Characteristics
Pulse Test at 21°C (70°F)
Bkgnd Drain: Continuous
62K ohms
0.046 mA @2.85V
Typical Discharge Characteristics
Pulse Drain: 2 seconds X 12 times/day
1K ohms
2.8 mA @2.8V
3.2
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
0
200
400
600
800
160
Bkgnd
3.0
Voltage, CCV
Voltage, CCV
Load: 62,000 ohms - Continuous
Typical Drain @ 2.85V: 0.046 mA
120
2.8
2.6
Pulse
80
2.4
2.2
40
2.0
IR
1.8
0
Service, Hours
Important Notice
5
10
15
20
IR, ohms
1.60 (0.063)
0
25
30
35
Capacity, mAh
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4112K
Page 1 of 1