PRODUCT DATASHEET 1-800-383-7323 / USA USA/CAN 1-800-383-7323 1-800-383-7323 / CANADA www.energizer.com ENERGIZER CR1216 Lithium Coin Specifications Classification: Chemical System: Designation: Nominal Voltage: Typical Capacity: Industry Standard Dimensions mm (inches) This Battery has Underwriters Laboratories component Recognition "Lithium Coin" Lithium / Manganese Dioxide (Li/MnO2) ANSI-5034LC, IEC-CR1216 3.0 Volts 34 mAh (to 2.0 volts) (Rated at 62K ohms at 21°C) 0.6 grams (0.02 oz.) 0.2 cubic centimeters (0.01 cubic inch) 1 microampere 118 milliwatt hr/g, 413 milliwatt hr/cc 0.008 grams (0.0003 oz.) MH29980 -30C to 70C ~1% / year Typical Weight: Typical Volume: Max Rev Charge: Energy Density: Typical Li Content: UL Recognized: Operating Temp: Self Discharge: 12.50 (0.492) 12.20 (0.480) 1.40 (0.055) 1.40 (0.055) Ref. 4.00 (0.157) Minimum (1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to serious injury or death in as little as 2 hours due to chemical burns and potential perforation of the esophagus. Immediately see doctor; have doctor phone (202) 625-3333. 1.10 (0.043) Ref. 0.30 (0.012) Maximum Ref. Permissible deflection from a flat. 0.03 (0.001) Minimum Ref. (Applies to top edge of gasket or edge of crimp, whichever is higher.) Simulated Application test Typical Performance at 21°C (70°F) Schedule: Typical Drains: at 2.85V (mA) (ohms) Cutoff 2.0V (hours) 0.046 62,000 739 Continuous Safety: Load (2) Battery compartment design. To prevent children from removing batteries, battery compartments should be designed with one of the following methods: a) a tool such as screwdriver or coin is required to open battery compartment or b) the battery compartment door/cover requires the application of a minimum of two independent and simultaneous movements of the securing mechanism to open by hand. Screws should remain captive with the battery door or cover. Internal Resistance Characteristics Pulse Test at 21°C (70°F) Bkgnd Drain: Continuous 62K ohms 0.046 mA @2.85V Typical Discharge Characteristics Pulse Drain: 2 seconds X 12 times/day 1K ohms 2.8 mA @2.8V 3.2 3.2 3.0 2.8 2.6 2.4 2.2 2.0 1.8 0 200 400 600 800 160 Bkgnd 3.0 Voltage, CCV Voltage, CCV Load: 62,000 ohms - Continuous Typical Drain @ 2.85V: 0.046 mA 120 2.8 2.6 Pulse 80 2.4 2.2 40 2.0 IR 1.8 0 Service, Hours Important Notice 5 10 15 20 IR, ohms 1.60 (0.063) 0 25 30 35 Capacity, mAh This datasheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 4112K Page 1 of 1