ENERGIZER CR1025
Lithium Coin
Specifications
Classification:
Chemical System:
Designation:
Nominal Voltage:
Typical Capacity:
Industry Standard Dimensions
mm (inches)
This Battery has Underwriters
Laboratories component Recognition
Typical Weight:
Typical Volume:
Max Rev Charge:
Energy Density:
Typical Li Content:
UL Recognized:
Operating Temp:
Self Discharge:
"Lithium Coin"
Lithium / Manganese Dioxide (Li/MnO2)
ANSI-5033LC, IEC-CR1025
3.0 Volts
30 mAh (to 2.0 volts)
(Rated at 68K ohms at 21°C)
0.7 grams (0.02 oz.)
0.2 cubic centimeters (0.01 cubic inch)
1 microampere
124 milliwatt hr/g, 435 milliwatt hr/cc
0.009 grams (0.0003 oz.)
MH29980
-30C to 60C
~1% / year
10.00 (0.394)
9.70 (0.382)
2.50 (0.098)
3.00 (0.118)
Minimum
2.20 (0.087)
0.30 (0.012) Maximum Ref.
Permissible deflection from a flat.
0.03 (0.001) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
Safety:
(1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to
serious injury or death in as little as 2 hours due to chemical burns and
potential perforation of the esophagus. Immediately see doctor; have
doctor phone (202) 625-3333.
(2) Battery compartment design. To prevent children from removing
batteries, battery compartments should be designed with one of the
following methods: a) a tool such as screwdriver or coin is required to open
battery compartment or b) the battery compartment door/cover requires
the application of a minimum of two independent and simultaneous
movements of the securing mechanism to open by hand. Screws should
remain captive with the battery door or cover.
Typical Discharge Characteristics
Cross Section
Load: 68K ohms - Continuous
Typical Drain @ 2.9V: 0.043 mA
3.2
Voltage, CCV
3.0
2.8
2.6
2.4
Simulated Application test
2.2
Typical Performance at 21°C (70°F)
2.0
Schedule:
1.8
0
200
400
600
800
Service, Hours
Continuous
Typical Drains:
at 2.9V
(mA)
Load
(ohms)
Cutoff
2.0V
(hours)
0.043
68,000
721
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4110I