ENERGIZER CR2016
Lithium Coin
Specifications
Classification:
Chemical System:
Designation:
Nominal Voltage:
Typical Capacity:
Industry Standard Dimensions
mm (inches)
This Battery has Underwriters
Laboratories component Recognition
Typical Weight:
Typical Volume:
Max Rev Charge:
Energy Density:
Typical Li Content:
UL Recognized:
Operating Temp:
Self Discharge:
"Lithium Coin"
Lithium / Manganese Dioxide (Li/MnO2)
ANSI / NEDA-5000LC, IEC-CR2016
3.0 Volts
90 mAh (to 2.0 volts)
(Rated at 30K ohms at 21°C)
1.9 grams (0.07 oz.)
0.5 cubic centimeters (0.03 cubic inch)
1 microampere
122 milliwatt hr/g, 464 milliwatt hr/cc
0.036 grams (0.0013 oz.)
MH29980
-30C to 60C
~1% / year
1.60 (0.063)
20.00 (0.787)
1.47 (0.058) Ref.
19.80 (0.780)
8.00 (0.314)
1.22 (0.048) Ref.
Minimum
0.08 (0.003) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
0.20 (0.008) Maximum Ref.
Permissible deflection from a flat.
Simulated Application test
Typical Performance at 21°C (70°F)
Schedule:
Typical Drains:
at 2.9V
(mA)
(ohms)
Cutoff
2.0V
(hours)
0.097
30,000
928
Continuous
Load
Safety:
(1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to
serious injury or death in as little as 2 hours due to chemical burns and
potential perforation of the esophagus. Immediately see doctor; have
doctor phone (202) 625-3333.
(2) Battery compartment design. To prevent children from removing
batteries, battery compartments should be designed with one of the
following methods: a) a tool such as screwdriver or coin is required to open
battery compartment or b) the battery compartment door/cover requires
the application of a minimum of two independent and simultaneous
movements of the securing mechanism to open by hand. Screws should
remain captive with the battery door or cover.
Internal Resistance Characteristics
Pulse Test at 21°C (70°F)
Bkgnd Drain: Continuous
30K ohms
0.097 mA @2.9V
Typical Discharge Characteristics
Pulse Drain: 2 seconds X 12 times/day
400 ohms
6.8 mA @2.7V
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
Voltage, CCV
Voltage, CCV
Load: 30K ohms - Continuous
Typical Drain @ 2.9V: 0.097 mA
0
200
400
600
Service, Hours
800
1000
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
120
Bkgnd
100
80
Pulse
60
40
20
IR
0
Important Notice
10
20
30
40
50
60
70
80
0
90 100
Capacity, mAh
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4118H
Page 1 of 1
IR, ohms
1.40 (0.055)