Photo ENERGIZER CR2 - Energizer Technical Information

PRODUCT DATASHEET
Asia Pacific Region
+852-31026623
ENERGIZER CR2
Photo
Specifications
Classification:
Chemical System:
Designation:
Nominal Voltage:
Storage Temp:
Operating Temp:
Typical Capacity:
Industry Standard Dimensions
(millimeters)
"Lithium"
Lithium / Manganese Dioxide (Li/MnO2)
IEC-CR2
3.0 Volts
-40°C to 60°C
-40°C to 60°C
800 mAh (to 2.0 volts)
(rated at 100 ohms at 21°C)
11 grams
5.2 cubic centimeters
1000 mA continuous (2500 mA pulse)
2 uA
0.28 grams
Typical Weight:
Typical Volume:
Max Discharge:
Max Rev Charge:
Typical Li Content:
15.60
15.10
0.70
Minimum
6.50
Maximum
Typical Discharge Characteristics
27.00
25.80
Rated Capacity
100 ohms continuous at 21°C
3.0
Voltage, CCV
0.50
0.05
8.50
Minimum
Contact Recess
This battery contains a Positive Temperature
Coefficient (PTC) safety device to limit current
during short circuit conditions.
2.5
2.0
1.5
1.0
0
Simulated Application Tests
10
40
Photoflash
1200 mA (3 sec on / 7 sec off)
Cutoff Voltage
Photoflash
(3 / 7 sec)
30
Hours
Typical Use Performance
Drain
(mA)
Load
(ohms)
---
100
34
---
---
900
---
---
---
1140
1200
---
---
760
---
1800
---
---
400
---
3.0
2.0V (21°C) 1.8V (21°C) 1.55V (21°C)
(hours)
(pulses)
(pulses)
Voltage, CCV
Type
(time)
Capacity
(continuous)
Photoflash
(3 / 27 sec)
Photoflash
(3 / 7 sec)
20
2.5
2.0
1.5
21°C
-20°C
1.0
0
150
300
450
600
750
900
Pulses
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Engineering Data
Form No. EBC - 8946AP-B
Page 1 of 1