2L76 - Energizer Technical Information

PRODUCT DATASHEET
European US/CAN
Region
1-800-383-7323
+ 44
(0) 208 920 2306
www.energizer.com
www.energizer.eu
ENERGIZER 2L76
Specifications
Classification:
Chemical System:
Designation:
Nominal Voltage:
Storage Temp:
Operating Temp:
Typical Capacity:
Industry Standard Dimensions
mm (inches)
This Battery has Underwriters
Laboratories component Recognition
"Lithium Photo"
Lithium / Manganese Dioxide (Li/MnO2)
IEC-CR11108
3.0 Volts
-40°C to 60°C
-40°C to 60°C
160 mAh (to 2.0 volts)
(Rated at 15k ohms at 21°C)
Typical Weight:
3.0 grams
Typical Volume:
1.1 cubic centimeters
Max Discharge:
60 mA continuous (80 mA pulse)
Max Rev Charge:
1 microampere
Typical Li Content:
0.056 grams
UL Listed:
MH12454
For complete details, please reference:
Shipping:
Global (except US): Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
United States: 49 CFR 173.185
11.60 (0.457)
10.60 (0.417)
Typical Discharge Characteristics
10.80 (0.425)
Schedule: Continuous
Typical Load: 15,000 ohms at 21°C
9.80 (0.386)
Voltage, CCV
3.0
2.5
2.0
1.5
1.0
0
Simulated Application Tests
200
400
600
800
Service (hours)
1000
1200
Typical Performance at 21°C
Cutoff Voltage
2.4V
2.0V
Schedule
Drain
Load
2.6V
(time)
(mA)
(ohms)
(hours)
(hours)
(hours)
0.16
15000
840
920
1000
Continuous
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 889949EU
Page 1 of 1