PRODUCT DATASHEET 1-800-383-7323 US/CAN www.energizer.com ENERGIZER 1CR2 Specifications (EL1CR2) Classification: Chemical System: Designation: Nominal Voltage: Storage Temp: Operating Temp: Typical Capacity: Industry Standard Dimensions mm (inches) This Battery has Underwriters Laboratories component Recognition Typical Weight: Typical Volume: Max Discharge: Max Rev Current: Typical Li Content: UL Listed: "Lithium" Lithium / Manganese Dioxide (Li/MnO2) ANSI-5046LC, IEC-CR15H270 3.0 Volts -40°C to 60°C (-40°F to 140°F) -40°C to 60°C (-40°F to 140°F) 800 mAh (to 2.0 volts) (Rated at 100 ohms at 21°C) 11.0 grams (0.4 oz.) 5.2 cubic centimeters (0.3 cubic inch) 1000 mA continuous (2500 mA pulse) 2 uA 0.28 grams (0.010 oz.) MH29980 15.60 (0.614) 15.10 (0.594) 0.70 (0.028) Minimum 6.50 (0.256) Maximum Typical Discharge Characteristics 27.00 (1.063) 25.80 (1.016) Rated Capacity 100 ohms continuous at 21°C 3.5 Voltage, CCV 0.50 (0.020) 0.05 (0.002) 8.50 (0.335) Minimum Contact Recess This battery contains a Positive Temperature Coefficient (PTC) safety device to limit current during short circuit conditions. 3.0 2.5 2.0 1.5 0 10 20 Simulated Application Tests Photoflash 1200 mA (3 sec on / 7 sec off) Cutoff Voltage Photoflash (3 / 7 sec) 40 Hours Typical Use Performance Drain (mA) Load (ohms) --- 100 34 --- --- 900 --- --- --- 1140 1200 --- --- 760 --- 1800 --- --- 400 --- 3.0 2.0V (21°C) 1.8V (21°C) 1.55V (21°C) (hours) (pulses) (pulses) Voltage, CCV Type (time) Capacity (continuous) Photoflash (3 / 27 sec) Photoflash (3 / 7 sec) 30 2.5 2.0 21°C 1.5 -20°C 1.0 0 150 300 450 600 750 900 Pulses Important Notice This datasheet contains typical information specific to products manufactured at the time of its publication. ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty. Form No. EBC - 4202G Page 1 of 1