EL1CR2 - Energizer Technical Information

PRODUCT DATASHEET
1-800-383-7323 US/CAN
www.energizer.com
ENERGIZER 1CR2
Specifications
(EL1CR2)
Classification:
Chemical System:
Designation:
Nominal Voltage:
Storage Temp:
Operating Temp:
Typical Capacity:
Industry Standard Dimensions
mm (inches)
This Battery has Underwriters
Laboratories component Recognition
Typical Weight:
Typical Volume:
Max Discharge:
Max Rev Current:
Typical Li Content:
UL Listed:
"Lithium"
Lithium / Manganese Dioxide (Li/MnO2)
ANSI-5046LC, IEC-CR15H270
3.0 Volts
-40°C to 60°C (-40°F to 140°F)
-40°C to 60°C (-40°F to 140°F)
800 mAh (to 2.0 volts)
(Rated at 100 ohms at 21°C)
11.0 grams (0.4 oz.)
5.2 cubic centimeters (0.3 cubic inch)
1000 mA continuous (2500 mA pulse)
2 uA
0.28 grams (0.010 oz.)
MH29980
15.60 (0.614)
15.10 (0.594)
0.70 (0.028)
Minimum
6.50 (0.256)
Maximum
Typical Discharge Characteristics
27.00 (1.063)
25.80 (1.016)
Rated Capacity
100 ohms continuous at 21°C
3.5
Voltage, CCV
0.50 (0.020)
0.05 (0.002)
8.50 (0.335)
Minimum
Contact Recess
This battery contains a Positive Temperature
Coefficient (PTC) safety device to limit current
during short circuit conditions.
3.0
2.5
2.0
1.5
0
10
20
Simulated Application Tests
Photoflash
1200 mA (3 sec on / 7 sec off)
Cutoff Voltage
Photoflash
(3 / 7 sec)
40
Hours
Typical Use Performance
Drain
(mA)
Load
(ohms)
---
100
34
---
---
900
---
---
---
1140
1200
---
---
760
---
1800
---
---
400
---
3.0
2.0V (21°C) 1.8V (21°C) 1.55V (21°C)
(hours)
(pulses)
(pulses)
Voltage, CCV
Type
(time)
Capacity
(continuous)
Photoflash
(3 / 27 sec)
Photoflash
(3 / 7 sec)
30
2.5
2.0
21°C
1.5
-20°C
1.0
0
150
300
450
600
750
900
Pulses
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4202G
Page 1 of 1