AC5 data sheet

EVEREADY BATTERY CO.
Internet: www.energizer.com
1-800-383-7323
/ USA/ USA
1-800-383-7323
1-800-383-7323
/ CANADA
1-800-383-7323
/ CANADA
+ 44 (0) 208 920 2306 / EUROPE
ENERGIZER NO. AC5
Industry Standard Dimensions in mm (inches)
Chemical System:
Zinc Air (ZnO2)
Designation:
Battery Voltage:
Average Weight:
Volume:
Average Capacity:
ANSI - 7012D, IEC - PR63
1.4 Volts
0.2 grams (0.01 oz.)
0.05 cubic centimeters (0.003 cubic inch)
33 mAh to 0.9 volts
(Rated at 3k ohms at 21ºC & 50% RH)
AC5
Cells:
TYPICAL DISCHARGE CHARACTERISTICS
Schedule: 16 hours/day
Typical Drain @ 1.3V: 0.43 & 0.22 milliamperes
Load: 3K & 6K ohms
Operating Voltage
1.4
1.3
1.2
1.1
1.0
0.9
3K
6K
0.8
0
30
60
90
120
150
Service, Hours
Simulated Application Test
Estimated Average Service at 21ºC (70ºF) and 50% RH
Cutoff Voltage
Schedule:
Typical Drains
at 1.3V
(milliamperes)
Load
(ohms)
0.9V
16 hours/day
0.43
3,000
77 Hours
16 hours/day
0.22
6,000
149 Hours
IMPEDANCE: The typical impedance of these cells on open circuit and during useful
discharge varies from 5-20 ohms. This applies over a frequency
range of 40-5,000 hertz and at the current drain shown above.
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
Form No. EBC - 4501B
Page 1 of 1