Energizer AC312 - Mercury Free - Energizer Technical Information

PRODUCT DATASHEET
European Region
+ 44 (0) 208 920 2306
www.energizer-eu.com
Energizer AC312 - Mercury Free
Specifications
(top view) (bottom view)
Industry Standard Dimensions
(mm)
Chemical System:
Tab Color:
Designation:
Nominal Voltage:
Typical Capacity:
Zinc Air (Zn/O2)
Brown
IEC-PR41
1.4 Volts
160 mAh (to 0.9 volts)
(Rated at 1.5k ohms at 21°C/50% RH)
Typical Weight:
Typical Volume:
0.5 grams
0.2 cubic centimeters
Impedance
The total opposition that a battery offers to the flow of
alternating current. Impedance is a combination of
resistance and reactance.
0.25
Minimum
5.00
Typical
The typical impedance of these cells on open circuit and
during useful discharge varies from 5-20 ohms. This
applies over a frequency range of 40-5,000 hertz at the
current drains shown below.
1.35R
Typical
7.90
7.55
3.60
Impedance vs. Frequency
3.25
20
Typical Discharge Characteristics
Schedule: 16 hours/day
Typical Drain @ 1.3V:
1.3 & 0.87 milliamperes
Load: 1K & 1.5K ohms
25% DoD
50% DoD
12
80% DoD
8
4
0
1.3
0.1
1.2
1
10
100
1000
Frequency (Hz)
10000 100000
1.1
Impedance vs. Depth of Discharge
1.0
0.9
1K
25
1.5K
0.8
0
40
80
120
160
200
Service, Hours
Simulated Application Test
Typical Performance at 21°C & 50% RH
Schedule:
16 Hours/Day
16 Hours/Day
Typical Drains:
at 1.3V
(milliamperes)
Load
(ohms)
Cutoff
0.9V
(hours)
1.3
0.87
1,000
1,500
123
184
Impedance (ohms)
Operating Voltage
1.4
Impedance (ohms)
00% DoD
16
20
15
10
40 Hz
5
1K Hz
0
0%
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
Depth of Discharge
Important Notice
This datasheet contains typical information specific to
batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
©Energizer Holdings, Inc. - All Rights Reserved
Engineering Data
Form No. EBC - 8837EU