MB3505 THRU MB3510

MB3505 THRU MB3510
SINGLE-PHASE 35.0AMPS. SILICON BRIDGE RECTIFIER
MB-25
FEATURE
1.142(29.0)
1.102(28.0)
.673(17.1)
.633(16.1)
.Surge overload ratings-400Amperes
.Low forward voltage drop
HOLE FOR
NO. 8 SCREW
MECHANICAL DATA
.Case: Molded plastic
.Epoxy: UL 94V-0 rate flame retardant
.Lead: MIL-STD- 202E, Method 208 guaranteed
.Polarity: As marked
.Mounting position: Any
.Weight: 30grams
.732(18.6)
.692(17.6)
.673(17.1) 1.142(29.0)
.633(16.1) 1.102(28.0)
.582(14.8)
.543(13.8)
.500
(12.7)
.033X.250
(0.8X6.4)
TYP.
.452
MAX
(11.5)
.480(12.2)
.425(10.8)
+ ~~
-
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(single-phase, half-wave, 60HZ, resistive or inductive load rating at 25°C, unless otherwise stated)
Type Number
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC blocking Voltage
Maximum Average Forward rectified Output Current
at TA=55°C
Peak Forward Surge Current 8.3ms single half sinewave superimposed on rate load (JEDEC method)
Maximum Forward Voltage Drop per element at
17.5A DC
Maximum DC Reverse Current
Ta =25°C
at rated DC blocking voltage
Ta =100°C
2
I t Rating for Fusing (t﹤8.3ms)
Typical Junction Capacitance (Note 1)
Typical Thermal Resistance (Note 2)
Storage Temperature
Operating Junction Temperature
SYM
BOL
MB
3505
MB
351
MB
352
MB
354
MB
356
MB
358
MB
3510
units
VRRM
VRMS
VDC
50
100
200
400
600
800
1000
V
35
70
140
280
420
560
700
V
50
100
200
400
600
800
1000
V
IF(AV)
35.0
A
IFSM
400
A
VF
1.0
V
10.0
uA
500.0
664
300
uA
A Sec
pF
2.2
°C /W
-55 to +150
°C
-55 to +125
°C
IR
2
It
CJ
R(JA)
TSTG
TJ
Note:
1. Measured at 1.0 MHz and applied reverse voltage of 4.0Vdc
2.Thermal Resistance from Junction to lead mounted on on P.C.B. with 0.5×0.5”(13×13mm) copper pads.
- 85 -
2
RATING AND CHARACTERISTIC CURVES (MB3505 THRU MB3510)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
FIG.2-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
INSTANEOUS FORWARD
CURRENT,(A)
AVERGE FORWARD RECTIFIED
CURRENT,(A)
100
35
17.5
Single Phase Half Wave
60Hz Resistive or
inductive Load
0
0
50
100
150
10
1.0
.1
200
TJ=25℃
Pulse Width=300μs
1% Duty Cycle
AMBIENT TEMPERTURE,(℃)
1.0
.8
.6
1.2
1.4
INSTANEOUS FORWARD VOLTAGE,(V)
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
FIG.3-MAXIMUN NON-REPETITIVE
FORWARD SURGE CURRENT
10
8.3ms Single Half
Sine-Wave (JEDEC
Method)
300
INSTANEOUS REVERSE
CURRENT,(μA)
PEAK FORWARD SURGE
CURRENT,(A)
400
200
100
0
0
10
100
1.0
TJ=25℃
.1
.01
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE
VOLTAGE,(%)
NUMBER OF CYCLES AT 60Hz
- 86 -
140