Fuses gL/gG - Line Protection Cylinder Fuses are typically used in industrial applications to protect electrical devices such as motors, drives, etc. Standard: IEC 20269-4-1 and IEC60269-1 Rated Voltage: 500V Rated Current/ Rated Voltate Cat. No. Std. Pk. 0.5A 1A 2A 4A 6A 8A 10A 12A 16A 20A 25A 32A* 2620017 2620000 2620001 2620003 2620005 2620006 2620007 2620008 2620009 2620011 2620013 2620015 10 10 10 10 10 10 10 10 10 10 10 10 Rated Current/ Rated Voltate Cat. No. Std. Pk. 0.5A 1A 2A 4A 6A 8A 10A 12A 16A 20A 25A 32A* 2621017 2621000 2621001 2621003 2621005 2621006 2621007 2621008 2621009 2621011 2621013 2621015 10 10 10 10 10 10 10 10 10 10 10 10 They are available in four sizes with a current range from 1 to 125 Amps. Cylinder Fuses have metal caps at both ends, and a porcelain fuse body. OPERATING CLASSES gL/gG - Line Protection Slow, typically used for distribution circuits or resistive loads. 10x38 Typical Markings: gL/gG aM - Motor Protection Fast acting short circuit protection, but slow acting overload protection. Typical Marking: aM *400V aM - Motor Protection Standard: IEC 20269-4-1 and IEC60269-1 Rated Voltage: 500V aR - Semiconductor Protection Partial range, short circuit protection for devices such as diodes, SCRs. etc. Typical Markings: Ultra Rapid™, Sitor™, Silcu™, Protister™, Recticur™, Ultra Quick™, aR gR - Semiconductor Protection Full range, short circuit protection for devices such as diodes, SCRs. etc. Typical Markings: Ultra Rapid™, Sitor™, Silcu™, Protister™, Recticur™, Ultra Quick™, gR 10x38 *400V aR - Semiconductor Protection Standard: IEC 60269-4-1 Breaking Capacity: ~200 kA Rated Voltage: ~600V** Note: Other fuse sizes and fuse holders are available. Please refer to the Altech European Fuse catalog for more information. In (A) Cat. No. 6 8 10 12 16 20 25 32 2625005 2625006 2625007 2625008 2625009 2625011 2625013 2625015 Operating I2-value (A’s) Power Dissipation Std. Pk. (W) 30 50 70 120 150 260 290 600 1.5 2 2.5 3 3.5 4.8 6 7.5 10 10 10 10 10 10 10 10 ** 6-25A (700V DC/ breaking capacity –– --- 50kA) 10x38 32A (400V DC/ breaking capacity –– --- 50kA) gR - Semiconductor Protection Standard: IEC 60269-4-1 Breaking Capacity: ~200 kA Rated Voltage: ~690V Ø10.3 mm (0.4 in.) 10.5 mm (0.4 in.) 6 mm (0.24 in.) 38 mm (1.5 in.) 10.5 mm (0.4 in.) 6 mm (0.24 in.) 10x38 Certified for 700V In (A) Cat. No. 1 2 4 6 8 10 12 16 20 25 30 2645126 2645127 2645128 2645129 2645130 2645131 2645132 2645133 2645134 2645135 2645136 Operating I2-value (A’s) 1.6 8 8 25 39 66 87 166 280 580 1.010 Power Dissipation Std. Pk. (W) 1 1.8 1.1 1.6 1.8 2.1 3.1 4.4 5.8 6.8 8.2 10 10 10 10 10 10 10 10 10 10 10 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 25