Safety Transponder System STS4

Safety Transponder System
STS4
In combination with the STS4/B actuating
element the STS4 sensor functions by the
identification of a unique 6-digit safety
code that is programmed during manufacture. The benefits of this non-contact,
transponder based safety sensor are
considerable: no mechanical wearing parts,
a high tolerance to lateral mis-alignment
between the sensor and actuating element,
plus high integrity 'anti-tamper' security
of the safety function, achieved by each
sensor being individually matched to one
defined transponder. In addition the Safety
Transponder System is unaffected by
dirty/contaminated environments.
Approved according to EN 954-1, Category
4, the STS4 has dual channel safety outputs
which are internally self monitored in both
the switched and unswitched state. These
outputs can be connected directly to a
Bernstein SCR safety relay or into the
customer's own safety control system.
L+
Safe
• 2-channel output
• Internal self monitoring
• Category 4 acc. to EN 954-1
Flexible
• Connects to safety control system or SCR
• 5 selectable positions for active face
Reliable
• Insensitive to mechanical vibrations
• Extended lateral offset
• Tamper-proof
• Insensitive to dirt
• No mechanical wear
analysis
channel 1
(CH1)
L1
A1
transponder
reading
head
analysis
channel 2
(CH2)
actuating
element
output
stage
2
L2
A2
STS4 / B
safety switch STS4
240
output
stage
1
L-
Sensing distance/offset
STS4/B
25
mm
20
hysteresis
m
s
15
10
STS4
response range
no operative range
- 20 -15 -10 -5
offset m
0
5
10 15 20
mm
5
1
0
switching distance s
The following values apply to parallel and
centred alignment of the active faces of
the safety switch and actuating element.
If the active faces lean towards each other,
the values will differ from those specified.
At an inclination of up to 30° the deviation
would be ± 10%.
Areas of use
40
22
45
40
Sensors
The STS4 Safety Transponder System
monitors the presence of removable/hinged
machinery guards and ensures that
hazardous work on and with machines or
applications can only be conducted if the
protective guard is in place. In areas where
safety devices are exposed to vibration
and mechanical wear, the STS4 really
demontrates its advantages by providing
tamper-proof access control and ensuring
dependable operator protection from the
dangerous movements of the machinery.
22
114
5,3
bore holes Ø 3,5
60
LED
15
30
31
13
5
3
7,3
M23x1
20
6
2
4
17
dimensioned drawing:
category 4 safety switch
1
15
3
dimensioned drawing:
actuating element
connector pin configuration
p
3
2
1
4
5
6
E1
E2
L+
L1
A1
L2
A2
L-
wiring diagram
Technical data
Description
Part number
STS4-N44US/020-KLS
6505054001
Operational data
Rated operating distance, hysteresis
Protection, weight
Operating voltage range L+
Operating mode
Output current
Ambient temperature range
Connection, plug
20 mm, < 15 %
IP 67, 250 g
15 … 24 … 30 VDC
2 NO contacts
< 400 mA per output, short circuit-proof
-30 … +70 °C
6-pole, coninverse RC (included)
241