71 05 wi 3 P th ol Gr e ou nd E3 0 Component Parts Pre-Assembled Units Covers Bulkhead Housing 29013 FEMALE Insert Hood 29008 29015 29015M 403001 403004 403004M 29640 Surface Mount Housing Standard Part Numbers are NPT threads. Part numbers with an “M” are metric thread. MALE 29014 403002 Hood Insert 29009 29017 29017M 403005 403005M Connectors should not be coupled and decoupled under electrical load. 6 Altech Corp.¤ ¥ (908) 806-9400 ¥ www.altechcorp.com 29642 Inserts Number of contacts Electrical data to DIN EN61 984 Current Voltage Rated Impulse Voltage Insulation Resistance Temperature Range Flammability Contacts Screw terminal Material Surface plated Contact resisitance Wire size Torque Stripping Length 3 Pole w/ ground 10A 240V 6KV 3 10A 240V 6kV ≥1010 Ω -40 to 125°C UL94-VO Metal Hoods & Housings Material Surface Seals Degree of Protection Acc To DIN EN60529 for coupled connectors Thread Size Copper alloy hard-silver ≤ 1m Ω 2.5mm2 / 14 AWG 0.5Nm 7.5mm Aluminum Powder coated NBR IP65 NPT 3/8” or M20 E307105 28 Ø3.2 30 40 17 29013 1 2 3 26 17 46.5 21 26.5 NPT 3/8 or M20 26.5 29015 29640 27 45 29008 23.5 Ø3.2 30 40 28 40 29014 NPT 3/8 or M20 1 2 26.5 27 50 25 21 12 3 35 26.5 29017 Connectors should not be coupled and decoupled under electrical load. 29642 All dimensions are shown in millimeters. To convert to inches divide by 25.4. Altech Corp.¤ ¥ (908) 806-9400 ¥ www.altechcorp.com SP EC IFI wi 3 P CA th ol TI Gr e O NS ou nd 29009 7