PS-30 Series Features: • • • • • • • • Specifications OUTPUT Cat. No. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) Universal AC input/ full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on 100% full load burn-in test 3 year warranty PS-3005 PS-3012 PS-3015 PS-3024 5V 3A 0 ~ 3A 15W 80mVp-p 12V 2A 0 ~ 2A 24W 120mVp-p 15V 2A 0 ~ 2A 30W 120mVp-p 24V 1.5A 0 ~ 1.5A 36W 150mVp-p Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 4.75 ~ 5.5V ±2.0% 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±1.0% ±1.0% 100ms, 30ms / 230VAC 100ms / 230VAC PROTECTION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 74% 81% 0.88A / 115VAC 0.48A / 230VAC COLD START 15A / 115VAC; 30A / 230VAC OVERLOAD ±1.0% ±1.0% ±1.0% ±1.0% 100ms, 30ms / 115VAC at full load 21ms / 115VAC at full load 82% ±1.0% ±1.0% 83% 105 ~ 160% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed OVERVOLTAGE ENVIRONMENT SAFETY & EMC 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type: Shut down overvoltage, clamping by zener diode WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% / ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL60950-1 EN60950-1 compliant Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms / 500VDC Compliance to EN55011 EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. The final equipment must be re-confirmed OTHERS that it still meets EMC directives. MTBF DIMENSION PACKING 441.5K hrs min. MIL-HDBK-217K (25˚C) 78x93x56mm (WxHxD) 0.27Kg; 48pcs / 14Kg / 1.02CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 78 Mechanical Specification 56 47 78 5 5 5 5 12.2 1 2 Terminal Pin. No Assignment 45 68 7 Assignment Pin No. Assignment AC/L 5,6 -V AC/N 7 LED +V 8 +V ADJ. 93 Pin No. 1 2 3,4 27.4 3 4 5 6 37.75 3 8 Block Diagram R E C TIF IE R S & F ILTE R E MI F ILTE R I/P P O WE R SWITC H ING R E C TIF IE R S & F ILTE R +V -V DE TE C TIO N C IR C U IT O .L.P. C O NTR O L O .V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 LOAD (%) LOAD (%) 80 60 40 70 60 50 20 -20 40 0 10 20 30 40 50 60 AMBIENT TEMPERATURE (°C) 70 (V E RTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 79