MEANWELL MWP-608

MWP-608
104W Triple Output Switching Power Supply
Features :
Universal AC input/Full range
Protections:Short circuit/Over load
Cooling by free air convection
2 years warranty
SPECIFICATION
MWP-608
MODEL
OUTPUT
OUTPUT NUMBER
CH1
CH2
CH3
DC VOLTAGE
5V
12V
24V
RATED CURRENT
10A
2A
1.25A
CURRENT RANGE
3 ~ 15A
0.2 ~ 4A
0.2 ~ 4A
RATED POWER
104W
120mVp-p
150mVp-p
RIPPLE & NOISE (max.) Note.2 50mVp-p
VOLTAGE ADJ. RANGE
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
INPUT
8.0%
-5,+10%
LINE REGULATION
0.5%
1.0%
1.0%
LOAD REGULATION
1.0%
6.0%
6.0%
SETUP, RISE, HOLD TIME
200ms, 50ms, 16ms at full load
VOLTAGE RANGE
88 ~ 132VAC/176 ~ 264VAC selected by switch
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
AC CURRENT
INRUSH CURRENT (max.)
2.8A/115VAC
1.7A/230VAC
COLD START 20A/115VAC
40A/230VAC
LEAKAGE CURRENT
PROTECTION OVER LOAD
FUNCTION
OPERATING DISPLAY
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
<3.5mA / 240VAC
150 ~ 200% rated output power (CH1:19.2 ~ 29.2)
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
Double color LED correct Range: Green(5~5.4Vref.); Wrong Range: Red
-10 ~ +60
20 ~ 90% RH non-condensing
-20 ~ +85
0.05%/
, 5 ~ 95% RH
(0 ~ 50
) on +5V output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
TUV EN60950-1 Approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
I/P-O/P, I/P-FG :100M Ohms/500VDC
SAFETY & ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
EMC
(Note 4)
Compliance to EN60555-2,-3
HARMONIC CURRENT
OTHERS
EMS IMMUNITY
MTBF
DIMENSION
PACKING
NOTE
Compliance to EN61000-4-2,3,4,5 Light industry level, criteria A
267K hrs min. MIL-HDBK-217F (25 )
180*110*50mm (L*W*H)
203*115*50mm(L*W*H) with terminal & fixed iron
0.9Kg; 16pcs/15.4Kg/0.95CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:MWP-608-SPEC 2004-12-01