PS-15 Series Features: • • • • • • • • • Specifications Universal AC input / full range Protections: Short Circuit / Overload / Over Voltage Cooling by free air convection DIN rail mountable Isolation class II LED indicator for power on No load power consumption <0.5W 100% full load burn-in test 3 year warranty Cat. No. PS-1505 PS-1512 PS-1515 PS-1524 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 5V 2.4A 0 ~ 2.4A 12W 80mVp-p 12V 1.25A 0 ~ 1.25A 15W 120mVp-p 15V 1A 0 ~ 1A 15W 120mVp-p 24V 0.63A 0 ~ 0.63A 15.2W 150mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 4.75 ~ 5.5V ±2.0% INPUT LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load 70ms / 230VAC 16ms / 115VAC at full load PROTECTION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (max.) INRUSH CURRENT (Typ.) 85 ~ 264VAC 120 ~ 370VDC 47 ~ 63Hz 77% 84% 0.88A / 115VAC 0.48A / 230VAC COLD START 35A / 115VAC 65A / 230VAC OUTPUT Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1µF & 47µF parallel capacitor 10.8 ~ 13.2V ±1.0% 13.5 ~ 16.5V ±1.0% 21.6 ~ 26.4V ±1.0% Tolerance: includes set up tolerance, line regulation and load regulation. OVERLOAD 83.50% ±1.0% ±1.0% 85% 105 ~ 160% rated output power Protection type: Constant current limiting recovers automatically after fault condition is removed (Hiccup mode) Constant current operation region is within 60 ~ 100% rated output voltage. OVERVOLTAGE ENVIRONMENT SAFETY & EMC 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type: Shut down overvoltage, clamping by zener diode WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MOUNTING -20 ~ +60˚C (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85˚C, 10 ~ 95% RH ±0.03% ˚C (0 ~ 50˚C) Component: 10 ~ 500Hz, 2G 10min. / 1cycle, 60 min. each long X,Y, Z axes Compliance to IEC60068-2-6 SAFETY STANDARDS UL60950-1 EN60950-1 compliant Design refer to EN50178 I/P-O/P: 3KVAC I/P-O/P: 100M Ohms/500VDC (25˚C; 70% RH) Compliance to EN55011 EN55022 (CISPR22); EN61204-3 Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024; ENV50204; EN61000-6-2; EN61204-3; heavy industry level; criteria A WITHSTAND VOLTAGE ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY The power supply is considered a component which will installed into a final equipment. OTHERS The final equipment must be re-confirmed that it still meets EMC directives. MTBF DIMENSION PACKING 1172.3K hrs min. MIL-HDBK-217K (25˚C) 25x93x56mm (WxHxD) 0.1Kg; 140pcs / 15Kg / 0.92CUFT All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25˚C of ambient temperature For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 76