Panel Mount Solid State Relays 4 th gen ID L O S S LA E R TAT E The Global Expert in Solid State Switching Technology Y Custom Sensors & Technologies (CST) is a specialist in sensing, control and motion products. Through its brands, BEI Kimco, BEI Sensors, BEI PSSC, Crouzet, Crydom, Kavlico, Newall and Systron Donner Inertial, CST offers customizable, reliable and efficient components for mission-critical systems in Aerospace & Defense, Transportation, Energy & Infrastructures, Commercial & Industrial OEMs, Medical, Food & Beverage and Building Equipment markets. All CST teams are deeply customer focused, continually striving to exceed customer expectations. They always look for a strong alliance with customers, develop proactive cooperation and ensure transparent relationships. CST focuses all its effort in providing the best components and services to fit customers “mission critical” systems. Capable of meeting the most demanding specifications and standards, even in harsh environments, CST is certified to supply challenging industry sectors such as aerospace, nuclear, automotive, train, medical and oil & gas. Always mastering advanced technologies while capitalizing upon well proven solutions, CST designs, manufactures and delivers the highest quality products and provides strong engineering support and adaptation capabilities. Crydom, a brand of Custom Sensors & Technologies (CST) and global expert in Solid State Relay Technology, has a distinguished record of providing high quality, world class Solid State Relay and Control Products for a variety of heating, lighting and motion control applications. Crydom products, coupled with unparalleled technical support, timely delivery and competitive pricing, provide Crydom’s clients with the innovative products and support necessary to succeed in today’s competitive and fast paced global markets. Crydom’s extensive selection of standard off-the-shelf products is constantly being updated and expanded through its continuous improvement and aggressive new product development programs. Utilizing state of the art designs, materials and technology, Crydom offers a wide range of AC and DC output SSRs and solid state contactors in industry standard Panel Mount, PCB Mount, DIN Rail and Plug-In packages, all meeting global safety and standards agency requirements such as CE, RoHS, UL, IEC, etc. Bolstered by four decades of Solid State Relay operations experience, Crydom also specializes and encourages adapted and fully custom-designed SSR products for nearly any application where unique specifications and optimized performance are critical for success. Crydom’s modern purpose-built 100,000 square foot manufacturing facility houses all aspects of its ISO certified operation including Design and Development Engineering, Manufacturing Operations and Quality Assurance, Customer Service, Finance, Marketing and General Management, permitting close coordination of all aspects of Crydom’s activities. Applications Engineering and Sales support are both performed in the field to provide Crydom’s Customers with the unparalleled technical and commercial support. Following rigid design guidelines and standards, Crydom products have set the bench mark for SSR performance and reliability world wide. In addition to award winning designs, Crydom has acquired an impressive list of patents related to SSRs and Solid State Controls, while continuing to develop new circuit and technology-related inventions as part of extensive R&D programs. To learn more about Crydom SSR technology and products, or how an alliance with Crydom can contribute to the success of your project, visit www.crydom.com or contact your authorized Crydom Distributor or Crydom Customer Service Representative today. Focused on premium value offers and committed to excellence, our company, with 4,700 employees worldwide and sales of $660M US in 2011, is the dependable and adaptable partner for the most demanding customers. SOL www.cstsensors.com ID LA E RE T A T S www.crydom.com Y Meet THE NEW & improved PANEL MOUNT Improved “SEMS” screw & washer CURRENT SOLID STATE RELAY NEW Improved touch safe cover CURRENT NEW Redesigned housing with anti-rotation barriers CURRENT NEW Direct output “lead frame” termination CURRENT NEW Improved circuit perfomance CURRENT NEW Low input current option CURRENT CURRENT NEW NEW Regulated control inputs Stress & epoxy free construction Improved thermal performance with DBC technology 3 Series 1 Series 1 120/240/480 VAC 10-125 Amp • • • • • • Crydom’s signature family of Solid State Relays Ratings from 10 to 125 Amp @ 24-280 VAC and from 25 to 90 Amp @ 80-530 VAC Back-to-back SCR output for heavy industrial loads Flexible 3-32 VDC, 18-36 VAC or 90-280 VAC Control Voltage Available with Zero-crossing (resistive loads) or Random Turn-on (inductive loads) output Optional Normally Closed ouput ("-B" suffix option) Output Specifications (A) x12xxx x24xxx x48xxx Operating Voltage Range [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] (B) 24 - 140 600 1 24 - 280 600 1 48 - 530 800 1 Output Specifications (A) Operating Frequency Range [Hz] (C) Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum Load Current [Arms] (D) Minimum Load Current [Arms] 1 Cycle Surge Current (50 AND 60 Hz) [Apk] Maximum l2t for Fusing (50/60 Hz) [A2 sec] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [ºC/W] Minimum Power Factor (@ Maximum Load) 10 A 25 A 40 A 50 A 75 A 90 A 110 A 125 A 47 - 440 500 10 0.15 115/120 66/60 1.15 1.03 0.5 47 - 440 500 25 0.15 239/250 285/259 1.15 0.8 0.5 47 - 440 500 40 0.15 597/625 1770/1629 1.15 0.5 0.5 47 - 440 500 50 0.15 597/625 1770/1629 1.15 0.45 0.5 47 - 440 500 75 0.15 954/1000 4555/4150 1.15 0.3 0.5 47 - 440 500 90 0.15 1145/1200 6560/5976 1.15 0.27 0.5 47 - 440 500 110 0.25 1432/1500 10249/9338 1.15 0.25 0.5 47 - 440 500 125 0.25 1670/1750 13950/12709 1.15 0.22 0.5 A Prefix D Prefix AxxxxE Suffix 90 - 280 Vrms 90 Vrms 10 Vrms 5 10 Current Regulated 20 ms 30 ms 3 - 32 VDC (4-32 VDC for 48 suffix) 3 VDC (G) 1 VDC -32 VDC 7 14 / 12 (48 suffix) Current Regulated 1/2 Cycle 1/2 Cycle 18 - 36 Vrms 18 Vrms 2 Vrms 16 20 Current Regulated 20 ms 30 ms Input Specifications (A) Control Voltage Range Minimum Turn-On Voltage Must Turn-Off Voltage Maximum Reverse Voltage Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance Maximum Turn-On Time [msec] (ZC and Random) (E) Maximum Turn-Off Time [msec] Series 1 General Specifications (A) Dialectric Strength, Input/Output/Base (50/60 Hz) [Vrms] Minimum Insulation Resistance (@ 500 VDC) [Ohms] Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range AC Control [ºC] Ambient Operating Temperature Range DC Control [ºC] Ambient Storage Temperature Range [ºC] Status Indicator Display (F) Weight (Typical) [oz] (gr) Housing Material UL94 Category Baseplate Material Humidity Shock/ Vibration 4000 109 8 -40 to 80 -40 to 80 -40 to 125 Yes, Green 2.6 (74.9) V-0 Aluminum 85% non-condensing Vibration Resistance according to IEC 60068-2-6: 0.35 mm and 0.75 mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: j 15 g / 11 ms (x12xxx only) Part Number Nomenclature Control Voltage A: 90-280 VAC D: 4-32 VDC (4-32 VDC for 48 suffix) AxxxxE: 18-36 VAC 4 A 12 Output Frecuency Blank: 47-440 Hz 4: 400 Hz (12 & 24 suffixes only) 10 Operating Voltage 12: 24-140 VAC 24: 24-280 VAC 48: 80-530 VAC 4 E K P G S Rated Load Current Input Status LED Termination 10: 10 Amp (12 & 24 suffixes only) Blank: Screw (12 & 24 suffixes only) F: Quick Connect Blank: Not Included 25: 25 Amp G: Included (up to 50 Amp. 40: 40 Amp (12 suffix only) Single pair [up to 25 Amp] 50: 50 Amp Double pair [50 Amp]) (H) 75: 75 Amp K: Round standoffs for 90: 90 Amp PC Board mounting 110: 110 Amp (24 suffix only) 125: 125 Amp (24 suffix only) Required for valid part number For options only and not required for valid part number For General Notes see page 9 Overvoltage Protection (12 & 24 suffixes only) Blank: Not Included P: Included Trigger Circuit Blank: Phototriac Snubber T: Phototransistor Blank: Not Included (Not needed with S: Included -B suffix, included (Not needed with T suffix, as standard) included as standard) H T -10 Thermal Pad Blank: Not Included H: Included Output Type -B: Normally Closed (Snubber included, not available with -10 option) -B Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 61000-4-6 : Conducted Electromagnetic Noise – Level 3 Complete specifications of these & other Crydom products available at: www.crydom.com HA & HD Series HA & HD Series 530/660 VAC 12-125 Amp • • • • Solid State Relay with ratings from 12 to 125 Amp @ 48-660 VAC Back-to-back SCR output for heavy industrial loads Flexible 4-32 VDC, 18-36 VAC or 90-280 VAC Control Voltage Available with Zero-crossing (resistive loads) or Random Turn-on (inductive loads) output Output Specifications (A) Hx48xx Hx60xx Operating Voltage Range [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] (B) 48 - 530 1200 1 48 - 660 1200 1 Output Specifications (A) Operating Frequency Range [Hz] (C) Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum Load Current [Arms] (D) Minimum Load Current [Arms] 1 Cycle Surge Current (50 AND 60 Hz) [Apk] Maximum l2t for Fusing (50/60 Hz) [A2 sec] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [ºC/W] Minimum Power Factor (@ Maximum Load) 12 A 25 A 50 A 75 A 90 A 110 A 125 A 47 - 440 500 12 0.15 134/140 66/60 1.15 1.03 0.5 47 - 440 500 25 0.15 239/250 285/259 1.15 0.8 0.5 47 - 440 500 50 0.15 597/625 1770/1629 1.15 0.45 0.5 47 - 440 500 75 0.15 954/1000 4555/4150 1.15 0.3 0.5 47 - 440 500 90 0.15 1145/1200 6560/5976 1.15 0.27 0.5 47 - 440 500 110 0.25 1432/1500 10249/9338 1.15 0.25 0.5 47 - 440 500 125 0.25 1670/1750 13950/12709 1.15 0.22 0.5 Input Specifications (A) Control Voltage Range Minimum Turn-On Voltage Must Turn-Off Voltage Maximum Reverse Voltage Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance Maximum Turn-On Time [msec] (ZC and Random) (E) Maximum Turn-Off Time [msec] A Prefix D Prefix AxxxxE Suffix 90 - 280 Vrms 90 Vrms 10 Vrms 5 10 Current Regulated 20 ms 30 ms 4 - 32 VDC 4 VDC (G) 1 VDC -32 VDC 7 12 Current Regulated 1/2 Cycle 1/2 Cycle 18 - 36 Vrms 18 Vrms 4 Vrms 16 20 Current Regulated 20 ms 30 ms HA & HD Series General Specifications (A) Dialectric Strength, Input/Output/Base (50/60 Hz) [Vrms] Minimum Insulation Resistance (@ 500 VDC) [Ohms] Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] Ambient Storage Temperature Range [ºC] Status Indicator Display (F) Weight (Typical) [oz] (gr) Housing Material UL94 Category Baseplate Material Humidity Shock/Vibration 4000 109 8 -40 to 80 -40 to 125 Yes, Green 2.6 (74.9) V-0 Aluminum 85% non-condensing Vibration Resistance according to IEC 60068-2-6: 0.35 mm and 0.75 mm Amplitude over 10-55 Hz Part Number Nomenclature Series H Control Voltage A: 90-280 VAC D: 4-32 VDC AxxxxE: 18-36 VAC A 48 Overvoltage Protection Blank: Not Included P: Included 25 Operating Voltage 48: 48-530 VAC 60: 48-660 VAC Required for valid part number For options only and not required for valid part number E K Rated Load Current 12: 12 Amp (48 suffix only) 25: 25 Amp 50: 50 Amp 75: 75 Amp (48 suffix only) 90: 90 Amp 110: 110 Amp (48 suffix only) 125: 125 Amp P G Snubber Blank: Not Included S: Included (Hx48xx and Hx48xxT only Trigger Circuit Not needed with T suffix, Blank: Phototriac T: Phototransistor included as standard) Termination Input Status LED Blank: Screw Blank: Not Included F: Quick Connect G: Included (Up to 50 Amp. Single pair [up to 25 Amp] (H) Double pair [50 Amp]) K: Round standoffs for PC Board mounting America Tel.: +1 (877) 502 5500 e-mail: [email protected] T Thermal Pad Blank: Not Included H: Included -10 Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 61000-4-6 : Conducted Electromagnetic Noise – Level 3 For General Notes see page 9 Questions? Call or e-mail: H S EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 5 H1 Series H1 Series H12D, H12WD, H16WD 530/660/690 VAC 25-125 Amp • • • • • Solid State Relay with ratings from 25 to 125 Amp @ 48-690 VAC Up to 1600 volt Blocking Back-to-back SCR output for heavy industrial loads Flexible 4-32 VDC Control Voltage Available with Zero-crossing (resistive loads) or Random Turn-on (inductive loads) output Output Specifications (A) Operating Voltage Range [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Cuurent @ Rated Voltage [mArms] Operating Frequency Range [Hz] Maximum On-State Voltage Drop @ Rated Current [Vrms] HP rating UL 508 / IEC 60947 [HP (KW)]: 240 VAC HP rating UL 508 / IEC 60947 [HP (KW)]: 380 VAC HP rating UL 508 / IEC 60947 [HP (KW)]: 480 VAC HP rating UL 508 / IEC 60947 [HP (KW)]: 600 VAC Output Specifications (A) Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum Load Current [Arms] (D) Minimum Load Current [Arms] 1 Cycle Surge Current (50 AND 60 Hz) [Apk] Maximum l2t for Fusing (50/60 Hz) [A2 sec] Thermal Resistance Junction to Case (Rjc) [ºC/W] Minimum Power Factor (@ Maximum Load) H12Dxxxx H12WDxxxx H16WDxx25 H16WDxx50 H16WDxx75 H16WDxx90 48 - 530 1200 10 47 - 63 1.15 N/A N/A N/A N/A 48 - 660 1200 1 47 - 440 1.15 N/A N/A N/A N/A 48 - 690 1600 1 47 - 440 1.3 1.5 (1.1) 2 (1.5) 3 (2.2) 3 (2.2) 48 - 690 1600 1 47 - 440 1.3 3 (2.2) 5 (3.7) 5 (3.7) 10 (7.4) 48 - 690 1600 1 47 - 440 1.2 5 (3.7) 7.5 (5.6) 10 (7.4) 15 (11.2) 48 - 690 1600 1 47 - 440 1.2 7.5 (5.6) 15 (11.2) 20 (14.9) 25 (18.6) 25 A 50 A 75 A 90 A 125 A 500 25 0.15 239/250 285/259 0.8 0.5 500 50 0.15 597/625 1770/1629 0.45 0.5 500 75 0.15 954/1000 4555/4150 0.3 0.5 500 90 0.15 1145/1200 6560/5976 0.27 0.5 500 125 0.25 1670/1750 13950/12709 0.22 0.5 DC Control Input Specifications (A) Control Voltage Range [VDC] Minimum Turn-On Voltage [VDC] Must Turn-Off Voltage [VDC] Maximum Reverse Voltage [VDC] Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance Maximum Turn-On Time [msec] (ZC and Random) (E) Maximum Turn-Off Time [msec] 4 - 32 4 (G) 1 -32 7 12 Current Regulated 1/2 Cycle 1/2 Cycle H12xxxx General Specifications (A) Dialectric Strength, Input/Output/Base (50/60 Hz) [Vrms] Minimum Insulation Resistance (@ 500 VDC) [Ohms] Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] Ambient Storage Temperature Range [ºC] Status Indicator Display (F) Weight (Typical) [oz] (gr) Housing Material UL94 Category Baseplate Material Humidity Shock/Vibration Part Number Nomenclature Series H1 Required for valid part number For options only and not required for valid part number For General Notes see page 9 6 -40 to 80 -30 to 80 -40 to 125 Yes, Green 2.6 (74.9) V-0 Aluminum 85% non-condensing Vibration Resistance according to IEC 60068-2-6: 0.35 mm and 0.75 mm Amplitude over 10-55 Hz Rated Load Current 25: 25 Amp 50: 50 Amp 75: 75 Amp Transient Overvoltage 90: 90 Amp 2D: 1200 Vpk (with Snubber) 2WD: 1200 Vpk (without Snubber) 125: 125 Amp (2D & 2WD suffixes only) 6WD: 1600 Vpk (without Snubber) 2WD H16xxxx 4000 109 8 48 25 K Overvoltage Protection (2D & 2WD suffixes only) Thermal Pad Blank: Not Included Blank: Not Included P: Included H: Included P G H Operating Voltage Termination Input Status LED 48: 48-530 VAC (2D suffix only) Blank: Screw Blank: Not Included 48-660 VAC (2WD suffix only) F: Quick Connect G: Included 60: 48-690 VAC (6WD suffix only) (Up to 50 Amp. Single pair [25 Amp] Double pair [50 Amp]) (H) K: Round standoffs for PC Board mounting -10 Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 61000-4-6 : Conducted Electromagnetic Noise – Level 3 Complete specifications of these & other Crydom products available at: www.crydom.com CSW Series CSW Series 280 VAC 10-90 Amp • • • • Heavy duty Solid State Relay with ratings from 10 to 90 Amp @ 24-280 VAC Back-to-back SCR output for heavy industrial loads Flexible 3-32 VDC Control Voltage Available with Zero-Crossing (resistive loads) or Random Turn-on (inductive loads) output Output Specifications (A) Operating Voltage Range [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] (B) Output Specifications (A) Operating Frequency Range [Hz] (C) Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum Load Current [Arms] (D) Minimum Load Current [Arms] 1 Cycle Surge Current (50 AND 60 Hz) [Apk] Maximum l2t for Fusing (50/60 Hz) [A2 sec] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [ºC/W] Minimum Power Factor (@ Maximum Load) 10 A 25 A 50 A 75 A 90 A 24 - 280 600 1 24 - 280 600 1 24 - 280 600 1 24 - 280 600 1 24 - 280 600 1 10 A 25 A 50 A 75 A 90 A 47 - 440 500 10 0.15 115/120 66/60 1.15 1.03 0.5 47 - 440 500 25 0.15 239/250 285/259 1.15 0.8 0.5 47 - 440 500 50 0.15 597/625 1770/1629 1.15 0.45 0.5 47 - 440 500 75 0.15 954/1000 4555/4150 1.15 0.3 0.5 47 - 440 500 90 0.15 1145/1200 6560/5976 1.15 0.27 0.5 DC Control Input Specifications (A) Control Voltage Range [VDC] Minimum Turn-On Voltage [VDC] Must Turn-Off Voltage [VDC] Maximum Reverse Voltage [VDC] Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance Maximum Turn-On Time [msec] (ZC and Random) (E) Maximum Turn-Off Time [msec] 3 - 32 3 (G) 1 -32 7 15 Current Regulated 1/2 Cycle 1/2 Cycle CSW Series General Specifications (A) Dialectric Strength, Input/Output/Base (50/60 Hz) [Vrms] Minimum Insulation Resistance (@ 500 VDC) [Ohms] Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] Ambient Storage Temperature Range [ºC] Status Indicator Display (F) Weight (Typical) [oz] (gr) Housing Material UL94 Category Baseplate Material Humidity Shock/Vibration 4000 109 10 -40 to 80 -40 to 125 Yes, Green 2.6 (74.9) V-0 Aluminum 85% non-condensing Vibration Resistance according to IEC 60068-2-6: 0.35 mm and 0.75 mm Amplitude over 10-55 Hz Part Number Nomenclature Operating Voltage 24: 24-280 VAC Series CSW 24 Required for valid part number For options only and not required for valid part number 10 Termination Blank: Screw F: Quick Connect (Up to 50 Amp. Single pair [up to 25 Amp] Double pair [50 Amp]) (H) Input Status LED K: Round standoffs for Blank: Not Included PC Board mounting G: Included K P Rated Load Current 10: 10 Amp 25: 25 Amp 50: 50 Amp 75: 75 Amp 90: 90 Amp G Overvoltage Protection Blank: Not Included P: Included S Thermal Pad Blank: Not Included H: Included H Snubber Blank: Not Included S: Included -10 Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On Designed in accordance with the requirements of IEC 62314 IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 61000-4-6 : Conducted Electromagnetic Noise – Level 3 For General Notes see page 9 Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 7 “T” Option “T” Option, Series 1 @ 120/240 VAC x12xxT, x24xxT 10-125 Amp • • Low Input Current option (@ 5 VDC) for low voltage output SSRs Trigger Circuit with Phototransistor Output Specifications (A) x12xxT (10 A, 25 A & 40 A only) x24xxT (all except 40 A) 24-140 600 8 24-280 600 10 Operating Voltage Range [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Output Specifications (A) Operating Frequency Range [Hz] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum Load Current [Arms] (D) Minimum Load Current [Arms] 1 Cycle Surge Current (50 AND 60 Hz) [Apk] Maximum I²t for Fusing (50/60Hz) [A² sec] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [°C/W] Minimum Power Factor (@ Maximum Load) Input Specifications (A) Control Voltage Range Minimum Turn-On Voltage Must Turn-Off Voltage Maximum Reverse Voltage [VDC] Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance Maximum Turn-On Time [msec] (ZC and Random) (E) Maximum Turn-Off Time [msec] 10 A 25 A 40 A 50 A 75 A 90 A 110 A 125 A 47-63 500 10 0.04 115/120 66/60 1.15 1.03 0.5 47-63 500 25 0.04 239/250 285/259 1.15 0.8 0.5 47-63 500 40 0.04 597/625 1770/1629 1.15 0.5 0.5 47-63 500 50 0.04 597/625 1770/1629 1.15 0.45 0.5 47-63 500 75 0.04 954/1000 4555/4150 1.15 0.3 0.5 47-63 500 90 0.04 1145/1200 6560/5976 1.15 0.27 0.5 47-63 500 110 0.25 1432/1500 10249/9338 1.15 0.25 0.5 47-63 500 125 0.25 1670/1750 13950/12709 1.15 0.22 0.5 A Prefix D Prefix E Suffix 90 - 280 Vrms 90 Vrms 10 Vrms 2 4.7 60K Ohms 10 ms 40 ms 3 - 32 VDC 3 VDC (J) 1 VDC -32 3.4 20 1500 Ohms 1/2 Cycle 1/2 Cycle 18 - 36 Vrms 18 Vrms 2 Vrms 2 4 9K 10 ms 40 ms Series 1 General Specifications (A) Dialectric Strength, Input/Output/Base (50/60 Hz) [Vrms] Minimum Insulation Resistance (@ 500 VDC) [Ohms] Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] Ambient Storage Temperature Range [ºC] Status Indicator Display (F) Weight (Typical) [oz] (gr) Housing Material UL94 Category Baseplate Material Humidity Shock/Vibration 4000 109 8 -40 to 80 -40 to 125 Yes, Green 2.6 (74.9) V-0 Aluminum 85% non-condensing Vibration Resistance according to IEC 60068-2-6: 0.35 mm and 0.75 mm Amplitude over 10-55 Hz For available part numbers see Series 1 Part Number Nomenclature on page 4 To view available Installation Sheet scan the QR code with your smartphone or visit www.crydom.com For General Notes see page 9 8 Complete specifications of these & other Crydom products available at: www.crydom.com “T” Option “T” Option, Series 1 @ 530/660 VAC & HA/HD Series A48xxT, HA48xxT, HA60xxT, D48xxT, HD48xxT, HD60xxT 12-125 Amp • • Low Input Current option (@ 5 VDC) for high voltage output SSRs Trigger Circuit with Photoransistor Output Specifications (A) Operating Voltage Range [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Output Specifications (A) Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum Load Current [Arms] (D) Minimum Load Current [Arms] 1 Cycle Surge Current (50 AND 60 Hz) [Apk] Maximum I²t for Fusing (50/60Hz) [A² sec] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [°C/W] Minimum Power Factor (@ Maximum Load) A48xxT D48xxT Hx48xxT Hx60xxT 48-530 1200 10 48-530 1200 10 48-530 1200 10 48-660 1200 5 12 A 25 A 50 A 75 A 90 A 110 A 125 A 500 12 0.04 134/140 66/60 1.15 1.03 0.5 500 25 0.04 239/250 285/259 1.15 0.8 0.5 500 50 0.04 597/625 1770/1629 1.15 0.45 0.5 500 75 0.04 954/1000 4555/4150 1.15 0.3 0.5 500 90 0.04 1145/1200 6560/5976 1.15 0.27 0.5 500 110 0.25 1432/1500 10249/9338 1.15 0.25 0.5 500 125 0.25 1670/1750 13950/12709 1.15 0.22 0.5 Input Specifications (A) Control Voltage Range Minimum Turn-On Voltage Must Turn-Off Voltage Maximum Reverse Voltage Minimum Input Current (for on-state) [mA] Maximum Input Current [mA] Nominal Input Impedance Maximum Turn-On Time [msec] (ZC and Random) (E) Maximum Turn-Off Time [msec] A Prefix D Prefix E Suffix 90 - 280 Vrms 90 Vrms 10 Vrms 2 4.7 60K 10 ms 40 ms 3 - 32 VDC 3 VDC (J) 1 VDC -32 VDC 2 2.5 Current Regulated 1/2 Cycle 1/2 Cycle 18 - 36 Vrms 18 Vrms 4 Vrms 2 4 9K 10 ms 40 ms General Specifications (A) Dialectric Strength, Input/Output/Base (50/60 Hz) [Vrms] Minimum Insulation Resistance (@ 500 VDC) [Ohms] Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] Ambient Storage Temperature Range [ºC] Status Indicator Display (F) Weight (Typical) [oz] (gr) Housing Material UL94 Category Baseplate Material Humidity Shock/Vibration 4000 109 8 -40 to 80 -40 to 125 Yes, Green 2.6 (74.9) V-0 Aluminum 85% non-condensing Vibration Resistance according to IEC 60068-2-6: 0.35 mm and 0.75 mm Amplitude over 10-55 Hz For available part numbers see Series 1 & HA/HD Part Number Nomenclature on pages 4 & 5 General Notes (A) All parameters at 25ºC unless otherwise specified. (B) Maximum Off-State Leakage Current is 10 mA for models with snubber (”S” and/or “-B” suffix options); 8 mA for Series 1 x12xxx models with snubber. (C) Operating Frequency Range is 47-63 Hz for models with snubber (”S” and/or “-B” suffix options). (D) Heat sinking required, see derating curves on page 13. Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] (E) Turn-On Time for Random Turn-On versions is 0.02 msec (DC Control Models). (F) LED indicates input status only. It does not represent output status. (G) Increased minimum input voltage by 1 VDC for operation from -20º to -40ºC. (H) For 50 Amp models UL requires the use of both blades. (J) For relays with option “G” minimum Control Voltage is 4.5 VDC. Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 9 Diagrams Mechanical Dimensions Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination Round Standoff Termination (Suffix “K”) 1.1 [27.9] 0.49 [12.4] 1 1.88 [47.6] OUTPUT 2 S O L I D S TAT E R E L AY 4 INPUT 1.1 [27.9] 0.49 [12.4] 0.89 [22.6] Mounting Hole/Slot 0.18 [4.5] DIA. 1 2.25 [57.3] 1.7 [43.2] Mounting Hole/Slot r 0.09 [2.2] 1.0 [25.4] 0.92 [23.3] Quick Connect Termination (Suffix “F”) - Up to 25 Amp Mounting Hole/Slot 0.18 [4.5] DIA. 3 Mounting Hole/Slot r 0.09 [2.2] 0.89 [22.6] New Accessories! Protective Cover & Hardware Kits 1.31 [33.4] Protective Cover Part number: KS101 Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. 1 1.88 [47.6] 8-32 Output Screw (2 places) Faston Terminal 0.25 x 0.032 (2 places) 2.25 [57.3] 1.7 [43.2] 1.75 [44.5] 1.75 [44.5] 1.1 [27.9] 0.49 [12.4] INPUT 1.08 [27.5] 2 S O L I D S TAT E R E L AY 4 3 1.0 [25.4] 1.88 [47.6] OUTPUT Mounting Hole/Slot 0.18 [4.5] DIA. OUTPUT 2 S O L I D S TAT E R E L AY 4 Mounting Hole/Slot r 0.09 [2.2] INPUT 2.25 [57.3] 1.7 [43.2] 3 1.0 [25.4] Part number: HK3 6-32 Input Screw (2 places) Faston Terminal 0.187 x 0.032 (2 places) 1.75 [44.5] Hardware Kit Bag with 2 threaded standoffs, 2 screws 8-32 x 1/4, and 2 lockwashers M8 for output, and 2 threaded standoffs, 2 screws 6-32 x 3/16, and 2 lockwashers M6 for input. Standoff screws provide additional mounting options such as PC Board mounting, using lug terminals or wire terminals to the side of the relay. 0.89 [22.6] 1.25 [31.8] Hardware Kit Part number: HK4 Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. Quick Connect Termination (Suffix “F”) - Up to 50 Amp 1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.18 [4.5] DIA. 1 1.88 [47.6] OUTPUT 8-32 Output Screw (2 places) Faston Terminal 0.25 x 0.032 (4 places) INPUT Hardware Kit Part number: HK5 Bag with 2 threaded standoffs, 2 screws 6-32 x 3/16, and 2 lockwashers M6 for input. Standoff screws provide additional mounting options such as PC Board mounting, using lug terminals or wire terminals to the side of the relay. 2 S O L I D S TAT E R E L AY 4 1.31 [33.4] 2.25 [57.3] 1.7 [43.2] 3 Hardware Kit Part number: HK6 Mounting Hole/Slot r 0.09 [2.2] 1.0 [25.4] 1.75 [44.5] 10 6-32 Input Screw (2 places) Faston Terminal 0.187 x 0.032 (2 places) 0.89 [22.6] 1.25 [31.8] Bag with 2 threaded standoffs, 2 screws 8-32 x 1/4, and 2 lockwashers M8 for output. Standoff screws provide additional mounting options such as PC Board mounting, using lug terminals or wire terminals to the side of the relay. Complete specifications of these & other Crydom products available at: www.crydom.com Diagrams Wiring Diagram Input Current Graphs (K, L) AC AC V V Standard Regulated “D” Inputs Load Load 2 ( ) 1 ( ) 1 ( ) 1 2 OUTPUT 1 S O L I D S TAT E R E L AY Input Current (mA) 25 2 ( ) OUTPUT 2 20 15 10 5 0 S O L I D S TAT E R E L AY 0 4 4 3 INPUT 4 (– / ) 3 (+ / ) INPUT 4 (– / ) 5 10 15 20 25 30 DC Input Voltage 3 3 (+ / ) “T” Option - Low Voltage Output 25 Wire Size (Solid / Stranded) Terminals Input Output Input Current (mA) TABLE 1. Recommended Wire Sizes Wire Pull-Out Strength (lbs)[N] 24 AWG (0.2 mm2) / 0.2 [minimum] 10 [44.5] 2 x 12 AWG (3.3 mm2) / 3.3 [maximum] 90 [400] 20 AWG (0.5 mm2) / 0.518 [minimum] 30 [133] 2 x 10 AWG (5.3 mm2) / 5.3 110 [490] 2 x 8 AWG (8.4 mm2) / 8.4 [maximum] 90 [400] 20 15 10 5 0 0 5 10 15 20 25 30 DC Input Voltage TABLE 2. Accessories (M) “T” Option - High Voltage Output Cover Hardware Kit Heat Sink Part No. Thermal Resistance Lug Terminal Thermal Pad [ºC/W] KS101 HK1 HS501DR 5.0 TRM1 HSP-1 HK3 HS301 / HS301DR 3.0 TRM6 HSP-2 HK4 HS251 2.5 HK5 HS201 / HS201DR 2.0 HK6 HS172 1.7 HS151 / HS151DR 1.5 HS103 / HS103DR 1.0 HS072 0.7 HS053 0.5 America Tel.: +1 (877) 502 5500 e-mail: [email protected] 2 1.5 1 0.5 0 0 5 10 15 20 25 30 DC Input Voltage (K) Load can be wired to either terminal 1 or terminal 2. Proper polarity must be observed all the time for the DC control power supply, with terminal 3 being positive with respect to terminal 4. Questions? Call or e-mail: Input Current (mA) 2.5 (L) Choose wire gauge according to actual load current (see TABLE 1). For larger wire sizes use lug terminals (see TABLE 2 for available part numbers). (M) See compatible accessories in corresponding datasheet. EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 11 Diagrams Equivalent Circuit Block Diagrams Diagram 1: Series 1 DC control, CSW Series Diagram 2: H12D models -DC 4 1 AC (N) +DC 3 Trigger Circuit -DC 4 1 AC (N) (P) Current Limiter 2 AC +DC 3 1 AC -DC 4 2 AC Diagram 4: H12WD models 1 AC Current Limiter Trigger Circuit (N) (P) (N) 2 AC +DC 3 Diagram 5: H16WD models (P) 2 AC Current Limiter Diagram 6: AC control “-B” models, A12xxxxT, A24xxxxT, A48xxxxT, HA48xxT -DC 4 1 AC (N) Trigger Circuit (Q) AC 3 (P) Current Limiter Diagram 3: Series 1 AC control, HAxxxx AC 4 AC/DC Converter Trigger Circuit (Q) AC 4 1 AC AC/DC Converter Trigger Circuit Trigger Circuit (P) (N) +DC 3 2 AC Current Limiter AC 3 2 AC Diagram 7: DC control “-B” models, D12xxT, D24xxT -DC 4 Diagram 8: HA60xxT 1 AC Trigger Circuit AC 4 1 AC AC/DC Converter (P) (N) 2 AC AC 3 -DC 4 1 AC Trigger Circuit (N) 2 AC Current Limiter Diagram 10: HD60xx -DC 4 Diagram 1 Series 1 DC control, CSW Series Diagram 2 H12D models Diagram 3 Series 1 AC control, HAxxxx Diagram 4 H12WD models Diagram 5 H16WD models Diagram 6 AC control “-B” models, A12xxxxT, A24xxxxT, A48xxxxT, HA48xxT Diagram 7 DC control “-B” models, D12xxT, D24xxT Diagram 8 HA60xxT Diagram 9 HD48xxT, D48xxT Diagram 10 HD60xx 1 AC Trigger Circuit (N) 2 AC Current Limiter 2 AC TABLE 3. Block Diagrams Diagram 9: HD48xxT, D48xxT +DC 3 (N) Elective Input Status LED, suffix “G”. (P) Elective Overvoltage Protection, suffix “P”. Option not available for A48xxxxT models. (Q) Elective Internal Snubber, suffix “S”. 12 (P) (N) +DC 3 +DC 3 Trigger Circuit Complete specifications of these & other Crydom products available at: www.crydom.com Diagrams Output Current Derating Curves 10 A 12 A 5ºC/W 3ºC/W No Heatsink 12 8 10 6 4 2 0 20 30 40 50 60 70 8 6 4 2 0 80 20 30 40 70 10 20 30 40 50 1ºC/W 60 70 20 30 40 10 0 60 20 30 40 0.5ºC/W 1.5ºC/W 70 1ºC/W 0.7ºC/W 20 10 60 70 80 Ambient Temperature (ºC) Questions? Call or e-mail: 1.5ºC/W 1ºC/W 0 80 20 30 40 Load Current (Amps) 40 20 30 40 50 60 70 80 125 A 0.5ºC/W 1.5ºC/W 1ºC/W 60 20 50 Ambient Temperature (ºC) 60 70 80 60 40 20 0 80 1ºC/W 0.7ºC/W 20 30 40 50 60 70 80 Ambient Temperature (ºC) TABLE 4. Heat Sinks 2ºC/W 1.5ºC/W 50 70 Ambient Temperature (ºC) 30 40 60 80 Crydom Part No. HS501DR HS301 / HS301DR HS201 / HS201DR HS151 / HS151DR 30 50 100 40 20 0.7ºC/W 15 100 50 0 80 30 120 H16WD6050 70 45 120 80 60 60 Ambient Temperature (ºC) 0 50 75 A 20 Ambient Temperature (ºC) 0.7ºC/W 40 110 A 1ºC/W 50 30 0.5ºC/W 2ºC/W 1.5ºC/W 30 80 Load Current (Amps) 90 80 70 60 50 40 30 20 10 0 20 Ambient Temperature (ºC) 40 90 A 0.7ºC/W 5 0 80 Load Current (Amps) Load Current (Amps) Load Current (Amps) 20 0.5ºC/W Load Current (Amps) 60 10 75 Ambient Temperature (ºC) Load Current (Amps) 50 50 30 3ºC/W 15 50 A 0.7ºC/W 3.5ºC/W 2ºC/W 40 0 2ºC/W 20 Ambient Temperature (ºC) 40 A 1.5ºC/W 1.5ºC/W No heatsink 25 Ambient Temperature (ºC) 1ºC/W 25 A 5ºC/W Load Current (Amps) 10 Load Current (Amps) Load Current (Amps) 3ºC/W America Tel.: +1 (877) 502 5500 e-mail: [email protected] HS103 / HS103DR HS072 HS053 Thermal Resistance [ºC/W] 5.0 3.0 2.0 1.5 1.0 0.7 0.5 EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 13 Diagrams Overload Current Capability Graphs (R) 25 A 250 100 200 Surge Current (Amp) Surge Current (Amp) 10 A & 12 A 120 80 60 40 20 0 0.01 0.1 1 150 100 50 0 0.01 10 0.1 Surge Duration (Secs) 40 A & 50 A Surge Current (Amp) Surge Current (Amp) 500 400 300 200 100 0.1 1 10 900 800 700 600 500 400 300 200 100 0 0.01 0.1 Surge Duration (Secs) 90 A 1 10 110 A 1200 Surge Current (Amp) Surge Current (Amp) 10 1500 1050 900 750 600 450 300 150 0.1 1 900 600 300 0 0.01 10 Surge Duration (Secs) 0.1 Surge Duration (Secs) Surge Current (Amp) 125 A 1800 1600 1400 1200 1000 800 600 400 200 0 0.01 0.1 1 10 Surge Duration (Secs) (R) Non repetitive peak surge current at Tj initial 40ºC. 14 1 Surge Duration (Secs) 1200 0 0.01 10 75 A 600 0 0.01 1 Surge Duration (Secs) Complete specifications of these & other Crydom products available at: www.crydom.com Crydom’s Range of Rating by Type of Package * 140 280 530 660 150 50 50 140 280 530 660 65 6 25 140 280 530 660 25 15 15 Voltage 1000 200 200 100 Current 160 30 20 5 Voltage (Volts) Current (Amp) (Volts) (Amp) Single Dual 3 Phase 280 5 * Crydom's maximum ratings Solid State Relay & Contactor Applications Although there are literally thousands of individual uses for Solid State Relays and Contactors, most can be categorized into the following applications: Heating Control This encompasses the largest segment of solid state relay users. Applications include, but are not limited to: professional food equipment, plastic molding/extrusion machinery, HVAC&R and soldering equipment. Benefits: Long life, no maintenance, safe product, easy to interface, as well as enabling temperature accuracy. Suitable for heater, fan, blower and valve control. Lighting Control These applications are usually broken down into three categories: theatrical, warehouse and commercial. Many of the products used in this segment are custom designed. Benefits: Dimming, silent operation, fast switching, long life, no maintenance, safe product, easy to interface, reduced parts count. Motion Control Includes elevators, lifts, hoists, exercise equipment, conveyor systems, solar trackers, fans, solenoid and valve control. Benefits: Endurance, shock & vibration resistance, Soft Start, reversing, no arcing, fast switching, long life, no maintenance, easy to interface, reduced parts count. Power Control Includes power supplies, transformers, regulators, inverters, converters, UPS systems, etc. as well as any load that is not specifically for heating, lighting or motion control. Benefits: Long life, silent operation, high speed switching, endurance, mechanical shock and vibration resistance, position insensitive, logic compatibility, arc and bounce free switching, and low electromagnetic emissions. 15 AMERICA EUROPE, MIDDLE EAST & AFRICA United States & Canada Crydom Inc 2320 Paseo de las Americas, Suite 201 San Diego, CA 92154 Sales Support: Tel.: +1 (877) 502 5500 Fax: +1 (619) 210 1590 [email protected] Technical Support: Tel.: +1 (877) 702 7700 [email protected] United Kingdom Crydom SSR Ltd Arena Business Centre Holyrood, Close Poole, Dorset BH17 7FJ Sales Support Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Technical Support [email protected] Mexico Automatismo Crouzet S.A. de C.V. Calzada Zavaleta 2505-C Col Sta Cruz Buenavista C.P. 72150 - Puebla Sales Support: Tel. : +52 (222) 409 7000 Fax : +52 (222) 409 7810 [email protected] Austria & Switzerland Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Belgium Tel.: +32 (0) 2 460 4413 Fax: +32 (0) 2 461 2614 [email protected] France China & Hong Kong Custom Sensors & Technologies Asia (Shanghai) Ltd. 13th floor Chang Feng International Tower 89 Yunling Road (East) Putuo District Shanghai, 200062 Sales Support Tel.: +86 (0) 21 6065 7725 Fax: +86 (0) 21 6065 7749 [email protected] Technical Support [email protected] Specifications are subject to change without prior notice. Crydom and the Crydom logo are registered trademarks of Crydom Inc. 04/2013 Rev.100413 Italy Tel.: +39 (0) 2 665 99 260 Fax: +39 (0) 2 665 99 268 [email protected] Spain Tel.: +34 902 876 217 Fax: +34 902 876 219 [email protected] Netherlands Tel.: +31 (0) 71 582 0068 Fax: +31 (0) 71 542 1648 [email protected] Germany Middle East, Africa & Other European Countries South Korea Custom Sensors & Technologies 14F, Kbiz DMC Tower, 189, Seongam-ro, Mapo-gu, Seoul 121-904, South Korea Tel.: +82 2 2629 8312 Fax: +82 2 2629 8310 [email protected] India Tel. : +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] South East Asian & Pacific Countries Custom Sensors & Technologies 2F, No. 39, Ji-Hu Road Nei-Hu Dist. Taipei 114, Taiwan Tel.: +886 2 8751 6388 ext.131 Fax: +886 2 2657 8725 [email protected] [email protected] CST Sensors India Pvt Ltd 4th Floor, Trident Towers, No. 23, 100 Ft- Ashoka Pillar Road, 2nd Block, Jayanagar, Bangalore- 560011 Tel: +91 (80) 4113 2204 /05 Fax: +91 (80) 4113 2206 [email protected] CAT/CR/P1/EN © 2013 Crydom Inc., All Rights Reserved. American Countries CST Latinoamerica Alameda Rio Negro, 1030, 18º andar – Conjunto 1803 CEP: 06454-000 Barueri - São Paulo Brasil Tel.: +55 (11) 2505 7500 Fax: +55 (11) 2505 7507 Tel.: +33 (0) 810 123 963 Fax: +33 (0) 810 057 605 [email protected] Tel.: +49 (0) 180 3000 506 Fax: +49 (0) 180 3205 227 [email protected] ASIA PACIFIC Southern & Central Distributed by :