The Global Expert in Solid State Switching Technology Panel Mount Solid State Relays Vol. II Crydom, a brand of Custom Sensors & Technologies (CST) and global expert in Solid State Relay Technology, has a distinguished record of providing high quality, world class Solid State Relay and Control Products for a variety of heating, lighting and motion control applications. Crydom products, coupled with unparalleled technical support, timely delivery and competitive pricing, provide Crydom’s clients with the innovative products and support necessary to succeed in today’s competitive and fast paced global markets. Crydom’s extensive selection of standard off-the-shelf products is constantly being updated and expanded through its continuous improvement and aggressive new product development programs. Utilizing state of the art designs, materials and technology, Crydom offers a wide range of AC and DC output SSRs and solid state contactors in industry standard Panel Mount, PCB Mount, DIN Rail and Plug-In packages, all meeting global safety and standards agency requirements such as CE, RoHS, UL, IEC, etc. Bolstered by four decades of Solid State Relay operations experience, Crydom also specializes and encourages adapted and fully custom-designed SSR products for nearly any application where unique specifications and optimized performance are critical for success. Crydom’s modern purpose-built 100,000 square foot manufacturing facility houses all aspects of its ISO certified operation including Design and Development Engineering, Manufacturing Operations and Quality Assurance, Customer Service, Finance, Marketing and General Management, permitting close coordination of all aspects of Crydom’s activities. Applications Engineering and Sales support are both performed in the field to provide Crydom’s Customers with the unparalleled technical and commercial support. Following rigid design guidelines and standards, Crydom products have set the bench mark for SSR performance and reliability world wide. In addition to award winning designs, Crydom has acquired an impressive list of patents related to SSRs and Solid State Controls, while continuing to develop new circuit and technologyrelated inventions as part of extensive R&D programs. To learn more about Crydom SSR technology and products, or how an alliance with Crydom can contribute to the success of your project, visit www.crydom.com or contact your authorized Crydom Distributor or Crydom Customer Service Representative today. www.crydom.com Custom Sensors & Technologies (CST) is a specialist in sensing, control and motion products. Through its brands, BEI Kimco, BEI Sensors, BEI PSSC, Crouzet, Crydom, Kavlico, Newall and Systron Donner Inertial, CST offers customizable, reliable and efficient components for mission-critical systems in Aerospace & Defense, Transportation, Energy & Infrastructure, Commercial OEMs, Industrial OEMs, Medical, Food and Beverage and Building Equipment markets. Focused on premium value offers and committed to excellence, CST, with 4,400 employees worldwide and sales of $590M US in 2014, is the dependable and adaptable partner for the most demanding customers. www.cstsensors.com 3 CW Series CW Series 280/660 VAC 10-125 Amps • • • • • • Output Specifications (A) Heavy duty Solid State Relays Ratings from 10 to 125 Amps @ 24-280 VAC or 48-660 VAC AC or DC control and Universal AC/DC control SCR Output for heavy industrial loads UL/CSA/TUV Approved, CE Compliant to EN60950-1 Certified according to EN 62314:2006 CWx2410 CWx2425 CWx2450 CWx2490 CWx24125 CWx4810 CWx4825 CWx4850 CWx4890 CWx48125 24-280 24-280 24-280 24-280 24-280 48-660 48-660 48-660 48-660 48-660 600 600 600 600 600 1200 1200 1200 1200 1200 380/400 570/600 810/850 1290/1350 1900/2000 380/400 570/600 810/850 1290/1350 1900/2000 Operating Voltage (47-440Hz) [Vrms] Transient Voltage [Vpk] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] Thermal Resistance Junction to Case (Rjc) [°C/W] 0.35 0.3 0.2 0.16 0.11 0.35 0.3 0.2 0.16 0.11 HP Rating UL 508/IEC60947 [HP] (KW): 120 VAC zero voltage t/o 0.5 (0.37) 0.75 (0.56) 1 (0.74) 2 (1.5) 3 (2.24) 0.5 (0.37) 0.75 (0.56) 1 (0.74) 2 (1.5) 3 (2.24) HP Rating UL 508/IEC60947 [HP] (KW): 240 VAC zero voltage t/o 1.5 (1.1) 2 (1.5) 3 (2.2) 5 (3.73) 7.5 (5.6) 1.5 (1.1) 2 (1.5) 3 (2.2) 5 (3.73) 7.5 (5.6) HP Rating UL 508/IEC60947 [HP] (KW): 480 VAC zero voltage t/o - - - - - 3 (2.24) 5 (3.7) 7.5 (5.6) 10 (7.4) 15 (11.2) HP Rating UL 508/IEC60947 [HP] (KW): 120 VAC instantaneous t/o 0.5 (0.4) 1 (0.7) 2 (1.0) 3 (2.2) 5 (3.7) 0.5 (0.4) 1 (0.7) 2 (1.0) 3 (2.2) 5 (3.7) HP Rating UL 508/IEC60947 [HP] (KW): 240 VAC instantaneous t/o 1.5 (1.1) 3 (2.2) 5 (3.5) 7.5 (5.6) 10 (7.5) 1.5 (1.1) 3 (2.2) 5 (3.5) 7.5 (5.6) 10 (7.5) HP Rating UL 508/IEC60947 [HP] (KW): 480 VAC instantaneous t/o - - - - - 3 (2.24) 5 (3.7) 7.5 (5.6) 10 (7.4) 15 (11.2) Output Specifications (A) Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] 10 A 25 A 50 A 90 A 1 1 1 1 125 A 1 500 500 500 500 500 Maximum Load Current [Arms] (B) 10 25 50 90 125 Minimum Load Current [mArms] 150 150 150 250 250 Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] Minimum Power Factor (at Maximum load) 1.3 1.3 1.3 1.3 1.25 720/660 1620/1500 3280/3000 8320/7560 18000/16600 0.5 0.5 0.5 0.5 0.5 Input Specifications (A) Control Voltage Range CWD CWA CWAxxxxE CWU 3-32 VDC [suffix 24] / 4-32 VDC [suffix 48] 90-280 VAC (D) 18-36 VAC 20-48 VDC/ 20-280 VAC Maximum Reverse Voltage -32 VDC - - - Minimum Turn-On Voltage 3 VDC [suffix 24] / 4 VDC [suffix 48] (C) 90 VAC 18 VAC 19 VDC/ VAC Minimum Turn-Off Voltage 1 VDC 10 VAC 4 VAC 5 VDC/ VAC Minimum Input Current (for on-state) [mA] 10 6 13 7/13 Maximum Input Current [mA] 15 10 15 11/9 Nominal Input Impedance [Ohms] Current Regulated 1/2 Cycle (E) 1/2 Cycle Maximum Turn-On Time [msec] Maximum Turn-Off Time [msec] 20 20 20 30 30 30 General Specifications (A) CW Series Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms] 4000 Minimum Insulation Resistance (@ 500 VDC) [Ohms] 109 8 Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] (F) -40 to 80 Ambient Storage Temperature Range [ºC] -40 to 125 LED Input Status Indicator Yes, Green Weight (Typical) [oz] (gr) 2.88 (81.53) Housing Material UL94 V-0 Baseplate Material Aluminum Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (G) 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (G) 7,210,376 hours (823 years) Part Number Nomenclature Series CW Control Voltage D: 3-32 VDC for suffix 24, 4-32 VDC for suffix 48 U: 20-48 VDC or 20-280 VAC A: 90-280 VAC AxxxxE: 18-36 VAC D 48 10 Operating Voltage 24: 24-280 VAC 48: 48-660 VAC Required for valid part number For options only and not required for valid part number 4 E Rated Load Current 10: 10 Amps 25: 25 Amps 50: 50 Amps 90: 90 Amps 125: 125 Amps Thermal Pad Blank: Not Included H: Included P H -10 Overvoltage Protection Blank: Not Included P: Included* Switching Type Blank: Zero Voltage Turn-On -10: Instantaneous Turn-On * Relay will self trigger between 900-1200Vpk. Not suitable for Capacitive Loads. IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 Complete specifications of these & other Crydom products available at: www.crydom.com CL Series CL Series 280 VAC 5-10 Amps • • • • • • Economical Solid State Relays with triac output Ratings of 5 and 10 Amps @ 280 VAC Flexible 3 to 32 VDC or 90 to 250 VAC Control Voltage New "K" Option for PCB mounting for IP00 versions UL Approved, CE Compliant to EN60950-1 Optional IP20 safety cover Output Specifications (A) Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] (H) Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec] Maximum Load Current [Arms] (B) Minimum Load Current [mArms] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 5A 10 A 24-280 24-280 600 600 7 7 500 500 5 10 150 150 84/100 120/126 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.5 Thermal Resistance Junction to Case (Rjc) [°C/W] 2.3 2.3 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 35/42 72/66 3 1.5 0.5 0.5 Minimum Heat Sink for Rated Current @ 40°C [°C/W] Minimum Power Factor (at Maximum load) Input Specifications (A) AC Input DC Input Control Voltage Range 90-250 VAC 3-32 VDC (C) Maximum Reverse Voltage N/A -32 VDC Minimum Turn-On Voltage 90 VAC 3 VDC Must Turn-Off Voltage 10 VAC 1 VDC Minimum Input Current (for on-state) [mA] 6 10 Maximum Input Current [mA] 10 14 Current Limited Current Limited Maximum Turn-On Time [msec] 20 1/2 Cycle (E) Maximum Turn-Off Time [msec] 30 1/2 Cycle Nominal Input Impedance [Ohms] General Specifications (A) CL Series Dielectric Strength, Input to Output (50/60Hz) [Vrms] 4000 Dielectric Strength, Input/Output to Ground (50/60Hz) 2500 Minimum Insulation Resistance (@ 500 VDC) [Ohms] 109 8 Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] (F) -40 to 80 Ambient Storage Temperature Range [ºC] -40 to 125 LED Input Status Indicator Yes, Green Weight (Typical) [oz] (gr) 2.88 (81.53) Housing Material UL94 V-0 Baseplate Material Aluminum Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (G) 11,641,553 hours (1,328 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (G) 7,210,376 hours (823 years) Part Number Nomenclature Control Voltage A: 90-250 VAC D: 3-32 VDC Series CL 240 A 10 Termination Blank: Screws & clamps K: Installed standoffs with screws for PC Board Cover mounting Blank: Not Included (IP00) (IP00 only, up to 50 Amps) C: Included (IP20) K Rated Load Current 05: 5 Amps 10: 10 Amps Load Voltage 240: 24-280 VAC R C H Switching Type Thermal Pad Blank: Zero Voltage Blank: Not Included Turn-On H: Included R: Instantaneous Turn-On Required for valid part number For options only and not required for valid part number Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 5 DC60 Series DC60 Series 60 VDC 3-7 Amps • • • • • Economical Bipolar transistor output Solid State Relays Ratings from 3 to 7 Amps @ 60 VDC Flexible 3.5 to 32 VDC Control Voltage New "K" Option for PCB mounting for IP00 versions UL Approved, CE Compliant to EN60950-1 Output Specifications (A) 3A 5A 7A Recommended Operating Voltage [VDC] 3-48 3-48 3-48 Absolute Maximum Rating [VDC] 60 60 60 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.1 Maximum Load Current [Adc] (B) 3 5 7 Minimum Load Current [mA] 20 20 20 Maximum Surge Current [Adc] (10 ms) Maximum On-State Voltage Drop @ Rated Current [VDC] Thermal Resistance Junction to Case (Rjc) [°C/W] Minimum Heat Sink @ Ambient [for max current = °C/W & Ta] 6 10 14 1.0 1.2 1.3 2 2 2 5 @ 60ºC 5 @ 60ºC 5 @ 40ºC Input Specifications (A) DC60 Series Control Voltage Range 3.5-32 VDC Maximum Reverse Voltage -32 VDC Minimum Turn-On Voltage (J) 3.5 VDC Minimun Turn-Off Voltage (K) 1 VDC Minimum Input Current (for on-state) [mA] 2.2 Maximum Input Current [mA] 25 Nominal Input Impedance [Ohms] 1500 Maximum Turn-On Time [msec] (L) 0.1 Maximum Turn-Off Time [msec] (M) 0.3 General Specifications (A) DC60 Series Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms] 4000 Minimum Insulation Resistance (@ 500 VDC) [Ohms] 109 8 Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] -30 to 80 Ambient Storage Temperature Range [ºC] -40 to 125 Weight (Typical) [oz] (gr) 2.46 (70) Housing Material UL94 V-0 Baseplate Material Aluminum Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (G) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (G) 11,545,504 hours (1,317 years) Part Number Nomenclature Series DC60 Termination Blank: Screws & clamps K: Installed standoffs with Output Type screws for PC Board Blank: Normally Open mounting (up to 50 Amps) -B: Normally Closed Control Voltage S: 3.5-32 VDC S K 3 Rated Load Current 3: 3 Amps 5: 5 Amps 7: 7 Amps H -B Thermal Pad Blank: Not Included H: Included Required for valid part number For options only and not required for valid part number 6 Complete specifications of these & other Crydom products available at: www.crydom.com D06D Series D06D Series 60 VDC 60-100 Amps • • • • • Solid State Relays with low impedance MOSFET output Ratings from 60 to 100 Amps @ 60 VDC Flexible 3.5 to 32 VDC Control Voltage New "K" Option for PCB mounting for IP00 versions UL Approved, CE Compliant to EN60950-1 Output Specifications (A) 60 A 80 A 100 A Recommended Operating Voltage [VDC] 1-48 1-48 1-48 Absolute Maximum Rating [VDC] 60 60 60 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.3 Maximum Load Current [Adc] (B) 60 80 100 Minimum Load Current [mA] (N) 5 5 5 180 220 270 Maximum Surge Current [Adc] (10 ms) Maximum On-State Voltage Drop @ Rated Current [VDC] Maximum On-State Resistance [RDS-ON] [Ohms] Thermal Resistance Junction to Case (Rjc) [°C/W] 0.6 0.7 0.5 0.010 0.008 0.005 0.51 0.73 0.73 Minimum Heat Sink for Rated Current @ 40°C [°C/W] 1.0 0.5 0.5 Maximun Pulse Wide Modulation Frequency [Hz] (P) 1000 900 700 Input Specifications (A) D06D Series Control Voltage Range [VDC] 3.5-32 Maximum Reverse Voltage [VDC] -32 Minimum Turn-On Voltage [VDC] (C) 3.5 Must Turn-Off Voltage [VDC] 1 Minimum Input Current (for on-state) [mA] 10 Maximum Input Current [mA] 15 Nominal Input Impedance Current Regulated Maximum Turn-On Time [μsec] 100 Maximum Turn-Off Time [μsec] 150 General Specifications (A) D06D Series Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms] 3750 Minimum Insulation Resistance (@ 500 VDC) [Ohms] 109 8 Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] (Q) -40 to 100 Ambient Storage Temperature Range [ºC] -40 to 125 Weight (Typical) [oz] (gr) 2.66 (75.5) Housing Material UL94 V-0 Baseplate Material Aluminum Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (G) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (G) 11,545,504 hours (1,317 years) Part Number Nomenclature Series D Operating Voltage 06D: 1-60 VDC 06D 60 Termination Blank: Screws & clamps K: Installed standoffs with screws for PC Board mounting (up to 50 Amps) K Rated Load Current 60: 60 Amps 80: 80 Amps 100: 100 Amps H Thermal Pad Blank: Not Included H: Included IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 Required for valid part number For options only and not required for valid part number Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 7 Series 1-DC Series 1-DC & 1-DCL 100/200/400/500 VDC 7-100 Amps • Solid State Relays with low impedance MOSFET output • Ratings from 7 to 100 Amps @ 100 VDC, from 7 to 40 Amps @ 200 VDC, from 7 to 12 Amps @ 400 VDC, and from 7 to 10 Amps @ 500 VDC • Flexible 3.5 to 32 VDC Control Voltage • New "K" Option for PCB mounting for IP00 versions • UL Approved, CE Compliant to EN60950-1 D1D07x D1D12x D1D20x D1D40x D1D60x D2D12x D2D40x D4D07x D4D12x D5D07x D5D10x Recommended Operating Voltage [VDC] Output Specifications (A) 1-72 1-72 1-72 1-72 1-72 D1D80x D1D100x D2D07x 1-72 1-72 1-150 1-150 1-150 1-300 1-300 1-385 1-385 Absolute Maximum Rating [VDC] 100 100 100 100 100 100 100 200 200 200 400 400 500 500 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3 0.3 0.1 0.2 0.3 0.1 0.3 0.3 0.3 0.3 0.2 0.3 Maximum Load Current [Adc] (B) 7 12 20 40 60 80 100 7 12 40 7 12 7 10 Minimum Load Current [mA] (N) 1 1 1 1 5 5 5 1 1 1 1 1 1 1 Maximum Surge Current [Adc] (10 ms) 23 28 42 106 180 220 330 22 31 106 18 36 19 29 Maximum On-State Voltage Drop @ Rated Current [VDC] 0.5 0.9 0.8 1.0 0.6 0.7 0.5 1.5 0.7 0.8 2.3 2.6 3.5 3.3 Maximum On-State Resistance [RDS-ON] [Ohms] Thermal Resistance Junction to Case (Rjc) [°C/W] 0.07 0.072 0.039 0.025 0.010 0.008 0.005 0.21 0.062 0.021 0.33 0.22 0.5 0.33 2.00 2.00 1.71 0.68 0.34 0.34 0.27 1.24 0.71 0.22 0.56 0.39 0.60 0.43 Minimum Heat Sink for Rated Current @ 40°C [°C/W] 5.0 3.0 2.0 1.0 1.0 0.5 0.5 3.0 3.0 0.7 2.0 1.0 1.0 0.7 Maximun Pulse Wide Modulation Frequency [Hz] (P) 5000 4000 3500 2500 1000 900 800 3500 2000 950 1200 900 1100 900 Input Specifications (A) Series 1-DC & 1-DCL Control Voltage Range [VDC] 3.5-32 Maximum Reverse Voltage [VDC] -32 Minimum Turn-On Voltage [VDC] (C) 3.5 Must Turn-Off Voltage [VDC] 1 Minimum Input Current (for on-state) [mA] 10 Maximum Input Current [mA] 15 Nominal Input Impedance Current Regulated Maximum Turn-On Time [μsec] 100 Maximum Turn-Off Time [μsec] 100 General Specifications (A) Series 1-DC & 1-DCL Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms] 3750 Minimum Insulation Resistance (@ 500 VDC) [Ohms] 109 8 Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] (Q) -40 to 100 Ambient Storage Temperature Range [ºC] -40 to 125 Weight (Typical) [oz] (gr) 2.66 (75.5) Housing Material UL94 V-0 Baseplate Material Aluminum Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (G) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (G) 11,545,504 hours (1,317 years) Part Number Nomenclature Series D Termination Blank: Screws & clamps K: Installed standoffs with screws for PC Board mounting (up to 50 Amps) Operating Voltage 1D: 1-100 VDC 2D: 1-200 VDC 4D: 1-400 VDC 5D: 1-500 VDC 1D 07 L K Rated Load Current 07: 7 Amps 10: 10 Amps (500 VDC only) 12: 12 Amps (not for 500 VDC) 20: 20 Amps (100 VDC only) 40: 40 Amps (100 & 200 VDC only) 60: 60 Amps (100 VDC only) 80: 80 Amps (100 VDC only) 100: 100 Amps (100 VDC only) Required for valid part number For options only and not required for valid part number 8 IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 Complete specifications of these & other Crydom products available at: www.crydom.com SSC Series SSC Series 1000 VDC 25 Amps • • • • • Solid State Relays with high voltage IGBT output Rated at 25 Amps @ 1000 VDC Flexible 8 to 16 VDC or 20 to 28 VDC Control Voltage New “K” Option for PCB mounting for IP00 versions CE Compliant to EN60950-1 Output Specifications (A) SSC Series Recommended Operating Voltage [VDC] 1-1000 Absolute Maximum Rating [VDC] 1200 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.3 Maximum Load Current [Adc] (B) 25 Minimum Load Current [mA] (N) 20 Maximum Surge Current [Adc] (10 ms) 75 Maximum On-State Voltage Drop @ Rated Current [VDC] 1.55 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.45 Minimum Heat Sink for Rated Current @ 40°C [°C/W] 1 Maximun Pulse Wide Modulation Frequency [Hz] (P) 500 Input Specifications (A) Option -12 Nominal Control Voltage [VDC] Option -24 12 24 Control Voltage Range [VDC] 8-16 20-28 Maximum Reverse Voltage [VDC] -16 -28 Minimum Turn-On Voltage [VDC] 8 20 Must Turn-Off Voltage [VDC] 1 Minimum Input Current (for on-state) [mA] 12.5 Maximum Input Current [mA] 15 Nominal Input Impedance [Ohms] Current Regulated Maximum Turn-On Time [μsec] 200 Maximum Turn-Off Time [μsec] 150 General Specifications (A) SSC Series Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms] 3750 Minimum Insulation Resistance (@ 500 VDC) [Ohms] 109 8 Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] (Q) -40 to 100 Ambient Storage Temperature Range [ºC] -40 to 125 Weight (Typical) [oz] (gr) 2.88 (81.53) Housing Material UL94 V-0 Baseplate Material Aluminum Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (G) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (G) 11,545,504 hours (1,317 years) Part Number Nomenclature Rated Load Current 25: 25 Amps Series SSC Termination Blank: Screws & clamp K: Installed standoffs with screws for PC Board mounting (up to 50 Amps) 1000 25 Operating Voltage 1000: 1-1000 VDC 24 K Control Voltage 12: 8-16 VDC 24: 20-28 VDC Required for valid part number For options only and not required for valid part number Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 9 PowerPlus DC PowerPlus DC Series 60/100/200/400/500 VDC 10-100 Amps • Solid State Relays with low impedance MOSFET output • Solid State Relays with ratings up to 100 Amps @ 60 VDC, 100 Amps @ 100 VDC, 40 Amps @ 200 VDC, 20 Amps @ 400 VDC and 60 Amps @ 500 VDC • Flexible 4 to 32 VDC or 30 to 60 VDC Control Voltage • New "K" Option for PCB mounting for IP00 versions • UL Approved, CE Compliant to EN60950-1 • Optional IP20 safety cover Output Specifications (A) DC60x10 DC60x20 DC60x40 DC60x60 DC60x80 DC60x100 1-48 1-48 1-48 1-48 1-48 1-48 Absolute Maximum Rating [VDC] 60 60 60 60 60 60 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.1 0.1 0.1 0.1 100 Recommended Operating Voltage [VDC] Maximum Load Current [Adc] (B) 10 20 40 60 80 Minimum Load Current [mA] (N) 2.5 2.5 2.5 2.5 2.5 2.5 Maximum Surge Current [Adc] (10 ms) 78 108 163 200 258 326 Maximum On-State Voltage Drop @ Rated Current [VDC] Maximum On-State Resistance [RDS-ON] [Ohms] Thermal Resistance Junction to Case (Rjc) [°C/W] 0.17 0.30 0.36 0.51 0.46 0.56 0.0170 0.0150 0.0090 0.0085 0.0058 0.0056 0.51 1.60 1.60 0.74 0.74 0.51 Minimum Heat Sink for Rated Current @ 40°C [°C/W] 5 5 2 1 0.5 0.5 Maximun Pulse Wide Modulation Frequency [Hz] (P) 1000 1000 900 900 700 700 DC100x10 DC100x20 DC100x40 DC100x60 DC100x80 DC100x100 Recommended Operating Voltage [VDC] Output Specifications (A) 1-72 1-72 1-72 1-72 1-72 1-72 Absolute Maximum Rating [VDC] 100 100 100 100 100 100 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.1 0.1 0.1 0.1 Maximum Load Current [Adc] (B) 10 20 40 60 80 100 Minimum Load Current [mA] (N) 2.5 2.5 2.5 2.5 2.5 2.5 Maximum Surge Current [Adc] (10 ms) 66 91 136 180 220 330 Maximum On-State Voltage Drop @ Rated Current [VDC] 0.13 0.24 0.28 0.36 0.40 0.40 Maximum On-State Resistance [RDS-ON] [Ohms] Thermal Resistance Junction to Case (Rjc) [°C/W] 0.013 0.012 0.007 0.006 0.005 0.004 1.27 0.73 0.58 0.45 0.34 0.27 Minimum Heat Sink for Rated Current @ 40°C [°C/W] N/R 5 2 1 0.5 0.5 Maximun Pulse Wide Modulation Frequency [Hz] (P) 1000 1000 900 900 700 700 Output Specifications (A) DC200x10 DC200x20 DC200x40 DC200x60 DC400x10 DC400x20 DC500x60 1-150 1-150 1-150 1-150 1-300 1-300 1-500 Absolute Maximum Rating [VDC] 200 200 200 200 400 400 500 Maximum Off-State Leakage Current @ Rated Voltage [mA] 0.2 0.2 0.2 0.2 0.4 0.4 0.1 Maximum Load Current [Adc] (B) 10 20 40 60 10 20 60 Minimum Load Current [mA] (N) 2.5 2.5 2.5 2.5 2.5 2.5 2.5 Recommended Operating Voltage [VDC] Maximum Surge Current [Adc] (10 ms) 71 71 142 224 32 48 95 Maximum On-State Voltage Drop @ Rated Current [VDC] 0.40 0.78 0.64 0.66 1.55 2.2 0.8 Maximum On-State Resistance [RDS-ON] [Ohms] Thermal Resistance Junction to Case (Rjc) [°C/W] 0.040 0.039 0.016 0.011 0.155 0.11 0.013 0.9 0.85 0.41 0.28 0.5 0.37 0.25 Minimum Heat Sink for Rated Current @ 40°C [°C/W] 5 2.5 1 0.5 1.5 0.5 0.7 Maximun Pulse Wide Modulation Frequency [Hz] (P) 1000 1000 900 700 900 700 500 Input Specifications (A) DC60xx DC100xx DC200xx DC400xx DC500Dx DC500Fx Control Voltage Range [VDC] 4-32 4-32 4-32 4-32 4-32 30-60 Maximum Reverse Voltage [VDC] -32 -32 -32 -32 -32 -60 Minimum Turn-On Voltage [VDC] (C) 4 4 4 4 4 30 Must Turn-Off Voltage [VDC] 1 1 1 1 1 20 Minimum Input Current (for on-state) [mA] 11 11 11 11 11 12 Maximum Input Current [mA] 14 14 14 14 14 17 Nominal Input Impedance Current Regulated Maximum Turn-On Time [μsec] 75 75 75 75 100 100 Maximum Turn-Off Time [μsec] 150 150 100 100 100 100 10 Complete specifications of these & other Crydom products available at: www.crydom.com PowerPlus DC General Specifications (A) PowerPlus DC Series Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms] 3750 Minimum Insulation Resistance (@ 500 VDC) [Ohms] 109 8 Maximum Capacitance, Input/Output [pF] Ambient Operating Temperature Range [ºC] (Q) -40 to 100 Ambient Storage Temperature Range [ºC] -40 to 125 LED Input Status Indicator Yes, Green Weight (Typical) [oz] (gr) 2.53 (72) except DC500xx, 2.88 (81.53) for DC500xxx Housing Material UL94 V-0 Baseplate Material Aluminum Humidity 85% non-condensing MTBF (Mean Time Between Failures) at 40°C ambient temperature (G) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (G) 11,545,504 hours (1,317 years) Part Number Nomenclature Termination Blank: Screws & clamps K: Installed standoffs with Control Voltage screws for PC Board D: 4-32 VDC mounting F: 30-60 VDC (500 suffix only) (IP00 only, up to 50 Amps) Series DC 100 D 40 Operating Voltage 60: 1-60 VDC 100: 1-100 VDC 200: 1-200 VDC 400: 1-300 VDC 500: 1-400 VDC K C Thermal Pad Blank: Not Included H: Included H Cover Rated Load Current Blank: Not Included (IP00) 10: 10 Amps C: Included (IP20) (Not valid with 500 suffix) 20: 20 Amps (Not valid with 500 suffix) 40: 40 Amps (Not valid with 400, 500 suffixes) 60: 60 Amps (Not valid with 400 suffixes) 80: 80 Amps (60D & 100D suffixes only) 100: 100 Amps (60D & 100D suffixes only) IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 Required for valid part number For options only and not required for valid part number General Notes (A) All parameters at 25°C unless otherwise specified. (B) Heat sinking required, see derating curves. For "K" option maximum current up to 50 Amp. (C) Increase minimum voltage by 1 V for operations from -20 to -40°C. (D) For ambient temperatures above 40°C the maximum control voltage must not exceed 250 VAC. (E) Turn-on time for Instantaneous turn-on versions is 0.1 msec for CWA, CWD & CL240D, and 7 ms for CWU models. (F) AC input models operating range is -20 to 80 °C (G) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). (H) Output will self trigger between 450-600 Vpk, not suitable for capacitive loads. (J) Minimum turn-on voltage for –B, DC control is 1 VDC and AC control is 10 Vrms/VDC. (K) Minimum turn-off voltage for –B, DC control is 3.5 VDC and AC control is 90 Vrms/VDC. Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] (L) Turn-on time for –B version is 300 μs (M) Turn-off time for –B version is 100 μs. (N) Low current loads and high ambient temperature can affect turn-on time. (P) 8 VDC Minimum control voltage. Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current. (Q) Decrease maximum control voltage 1.35V/°C above 80°C ambient temperature. (R) Select "P" option for overvoltage protection. (S) Option "K" is intended only for use in attaching a printed circuit board to the SSR or mounting the SSR to a printed circuit board (PCB thicknesses from .031 to .093 inches [0.79 to 2.36 mm]). EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 11 Diagrams Block Diagrams Diagram 1: CW Series, AC Control Diagram 2: CW Series, DC Control AC/-DC 4 1 AC Current Limiter AC/DC Converter -DC 4 1 AC (R) Trigger Circuit (R) Trigger Circuit Current Limiter AC/+DC 3 2 AC +DC 3 2 AC Diagram 3: CL Series, AC Control Diagram 4: CL Series, DC Control AC 4 1 AC -DC 4 1 AC Current Limiter AC/DC Converter Trigger Circuit Trigger Circuit Current Limiter AC 3 2 AC +DC 3 2 AC Diagram 5: DC60 Series Diagram 6: 1-DC, 1-DCL, D1D, D06D Series +DC 3 1 +DC Control Circuit +DC 3 2 +DC Trigger Circuit Control Circuit Trigger Circuit Current Limiter -DC 4 2 -DC -DC 4 1 -DC Diagram 7: SSC Series Diagram 8: PowerPlus DC Series +DC 3 2 +DC Control Circuit +DC 3 2 +DC Trigger Circuit Control Circuit Current Limiter Trigger Circuit Current Limiter -DC 4 1 -DC -DC 4 1 -DC TABLE 1. Block Diagrams Diagram 1 CW Series, AC Control Diagram 2 CW Series, DC Control Diagram 3 CL Series, AC Control Diagram 4 CL Series, DC Control Diagram 5 DC60 Series Diagram 6 1-DC, 1-DCL, D1D, D06D Series Diagram 7 SSC Series Diagram 8 PowerPlus DC Series Wiring Diagrams (Ÿ) Inductive loads must be diode suppresed (Ÿ) V V (Ÿ) (Ÿ) Load OUTPUT +2 S O L I D S TAT E R E L AY 4 4 (–) 12 INPUT +3 3 (+) 1 (–) 1 2 (+) OUTPUT 2 S O L I D S TAT E R E L AY 4 4 (–) V - Load + 1 2 (+) (Ÿ) Load + 1 (–) + - + Load + + V + DC60Sx (Ÿ) Inductive loads must be diode suppresed + - All DC Output Relays, Except DC60Sx INPUT +3 3 (+) 1 (+) +1 2 (–) OUTPUT 2 S O L I D S TAT E R E L AY 4 4 (–) INPUT +3 3 (+) Complete specifications of these & other Crydom products available at: www.crydom.com 1 (+) +1 2 (–) OUTPUT 2 S O L I D S TAT E R E L AY 4 4 (–) INPUT +3 3 (+) Diagrams Wiring Diagrams New Accessories! All AC Output Relays AC V Protective Cover & Hardware Kit AC V Protective Cover Load 1 ( ) 1 2 ( ) OUTPUT 1 ( ) 2 1 S O L I D S TAT E R E L AY 4 INPUT 4 (– / ) Part number: KS101 Load Clear plastic cover compatible with all new S1 designs. Safety covers provide added protection from electric shock when installing or checking equipment. Not applicable for IP20 models (CW, CL & PowerPlus DC Series). 2 ( ) 2 OUTPUT Hardware Kit S O L I D S TAT E R E L AY 4 3 3 (+ / ) Bag with 2 square brass accessories and 2 screw 8-32 x 5/8 for output. Used to mount TMR1 lug terminals. 3 INPUT 4 (– / ) Part number: HK4 3 (+ / ) TABLE 2. Recommended Accessories Mechanical Dimensions Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination 1.1 [27.9] 0.49 [12.4] 1 1.88 [47.6] OUTPUT INPUT Hardware Kit KS101 HK1 HK4 (ʋ) 2 S O L I D S TAT E R E L AY 4 0.89 [22.6] Mounting Hole/Slot 0.19 [4.9] DIA. Cover 2.25 [57.3] 1.7 [43.2] 3 Mounting Hole/Slot r 0.09 [2.2] 1.0 [25.4] 0.92 [23.3] 1.75 [44.5] 1.1 [27.9] 0.49 [12.4] 1 OUTPUT INPUT 1.0 [25.4] 1.75 [44.5] Lug Terminal Thermal Pad HS501DR 5.0 TRM1 HSP-1 HS301 / HS301DR 3.0 TRM6 HSP-2 HS251 2.5 HS201 / HS201DR 2.0 HS202 / HS202DR 2.0 HS172 1.7 HS151 / HS151DR 1.5 HS122 / HS122DR 1.2 HS103 / HS103DR 1.0 HS101 1.0 HS073 0.7 HS072 0.7 HS053 0.5 HS033 0.36 HS023 0.25 Screw Termination, IP20 (Option "C" & CW Series) Mounting Hole/Slot 0.19 [4.9] DIA. 1.1 [27.9] 0.49 [12.4] 1.04 [26.4] (2 places) Mounting Hole/Slot 0.19 [4.9] DIA. 2 S O L I D S TAT E R E L AY 4 Thermal Resistance [ºC/W] (ʋ) Not suitable for use with IP20 versions Standoff Termination (Option "K") (S) 1.88 [47.6] Heat Sink Part No. 2.25 [57.3] 1.7 [43.2] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 2.32 [58.8] 3 0.93 [23.6] (4 places) 1.0 [25.4] 1.0 [25.4] 1.22 [30.9] 1.75 [44.5] (2 places) Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 13 Derating Curves Derating Curves: CW Series CWxxx10 CWxxx25 No Heat Sink (T) 5°C/W 2°C/W 1°C/W 8 6 4 2 20 15 10 5 0 0 20 30 40 50 60 70 40 Ambient Temperature (ºC) 0.7°C/W 40 30 20 10 50 60 70 80 30 20 40 Ambient Temperature (ºC) 50 60 70 80 Ambient Temperature (ºC) CWxxx125 CWxxx90 0.5°C/W 2°C/W 0 30 20 80 1.5°C/W 50 Load Current (Amps) Load Current (Amps) Load Current (Amps) 5°C/W 25 10 0.36°C/W 1.5°C/W 1°C/W 0.5°C/W 1°C/W 0.7°C/W 120 Load Current (Amps) 90 Load Current (Amps) CWxxx50 3°C/W 75 60 45 30 15 100 80 60 40 20 0 0 30 20 40 50 60 70 20 80 30 40 50 60 70 80 Ambient Temperature (ºC) Ambient Temperature (ºC) Derating Curves: CL Series CL240x05 2°C/W CL240x10 No Heat Sink (T) 3°C/W 1.5°C/W No Heat Sink (T) 2°C/W 10 Load Current (Amps) Load Current (Amps) 5 4 3 2 1 0 8 6 4 2 0 20 30 40 50 60 70 80 20 30 Ambient Temperature (ºC) 40 50 60 70 80 Ambient Temperature (ºC) Derating Curves: DC60 Series DC60Sx3 DC60Sx5 No Heat Sink (T) 5°C/W 2 1.5 1 0.5 0 7 Load Current (Amps) Load Current (Amps) Load Current (Amps) 2.5 4 3 2 1 0 20 30 40 50 60 70 30 Ambient Temperature (ºC) 40 50 0.5°C/W 5°C/W 70 40 20 50 60 2 1 20 30 40 50 1.5°C/W 70 80 Ambient Temperature (ºC) 90 100 60 70 80 Ambient Temperature (ºC) D06D100 0.5°C/W 5°C/W 3°C/W 1.5°C/W 5°C/W 3°C/W 100 60 40 20 0 0 40 3 80 Load Current (Amps) Load Current (Amps) Load Current (Amps) 60 80 30 4 D06D80 2°C/W 60 20 5 Ambient Temperature (ºC) D06D60 1°C/W 6 0 20 80 No Heat Sink (T) 5°C/W 5 3 14 DC60Sx7 No Heat Sink (T) 5°C/W 80 60 40 20 0 20 30 40 50 60 70 80 90 100 20 30 40 Ambient Temperature (ºC) Complete specifications of these & other Crydom products available at: www.crydom.com 50 60 70 80 Ambient Temperature (ºC) 90 100 Derating Curves Derating Curves: Series 1-DC & 1-DCL D1D07 D1D12 No Heat Sink (T) 5°C/W 3°C/W 5 4 3 2 1 8 4 0 20 30 40 50 60 70 80 90 100 30 40 50 1°C/W 5°C/W 80 90 20 100 20 10 60 70 1.5°C/W 80 90 0.5°C/W 5°C/W 40 20 100 30 40 50 60 70 80 90 40 20 40 50 60 70 80 90 4 3 2 1 3°C/W 30 40 50 60 70 80 90 10 0 50 60 70 80 90 No Heat Sink (T) 4 2 30 40 50 60 70 80 90 100 90 100 D4D12 No Heat Sink (T) 3°C/W 1°C/W 2°C/W 5ºC/W 12 5 4 3 2 1 10 8 6 4 2 0 20 30 40 Ambient Temperature (ºC) 50 60 70 80 90 100 Ambient Temperature (ºC) D5D07 1°C/W 100 Ambient Temperature (ºC) 6 100 90 6 20 0 40 80 8 100 Load Current (Amps) Load Current (Amps) 20 70 5°C/W D4D07 2°C/W 5°C/W 30 60 10 Ambient Temperature (ºC) 7 30 50 0 20 40 20 40 D2D12 5 D2D40 1.5°C/W 5°C/W 3°C/W 12 Ambient Temperature (ºC) 0.7°C/W 30 No Heat Sink (T) 5°C/W 6 100 100 Ambient Temperature (ºC) 0 0 90 20 20 Load Current (Amps) Load Current (Amps) 60 80 40 D2D07 3°C/W 5°C/W 80 70 60 100 7 30 1.5°C/W Ambient Temperature (ºC) 3°C/W 60 0 20 100 20 50 D1D80 2°C/W D1D100 0.5°C/W 40 Ambient Temperature (ºC) 0 50 30 80 Ambient Temperature (ºC) Load Current (Amps) 70 Load Current (Amps) Load Current (Amps) Load Current (Amps) 30 0 Load Current (Amps) 60 60 40 5 D1D60 3°C/W 40 30 10 Ambient Temperature (ºC) D1D40 20 15 0 20 Ambient Temperature (ºC) 1°C/W No Heat Sink (T) 3°C/W 20 Load Current (Amps) 6 0 20 30 40 50 60 70 80 Ambient Temperature (ºC) D5D10 3°C/W 0.7°C/W 5ºC/W 2°C/W 5°C/W 10 7 6 Load Current (Amps) Load Current (Amps) 2°C/W 12 Load Current (Amps) Load Current (Amps) 7 D1D20 No Heat Sink (T) 5°C/W 5 4 3 2 1 0 8 6 4 2 0 20 30 40 50 60 70 80 90 100 20 30 Ambient Temperature (ºC) Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] 40 50 60 70 80 90 100 Ambient Temperature (ºC) EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 15 Derating Curves Derating Curves: SSC Series SSC1000 1.5°C/W 2°C/W 5°C/W Load Current (Amps) 25 20 15 10 5 0 20 30 40 50 60 70 80 90 100 Ambient Temperature (ºC) Derating Curves: PowerPlus DC Series DC60D10 DC60D20 No Heat Sink (T) 5°C/W 6 4 2 15 10 5 0 20 30 40 50 60 70 80 90 100 30 40 50 DC60D60 1.5°C/W 20 80 90 100 20 50 60 70 80 90 20 30 40 50 60 70 80 90 0 60 70 80 90 40 50 60 70 80 90 0 60 70 80 90 100 100 3°C/W 90 100 5ºC/W 20 30 40 1.5°C/W 50 60 70 80 Ambient Temperature (ºC) DC100D100 5°C/W 3°C/W 0.5°C/W 1.5°C/W 5°C/W 3°C/W 100 60 40 20 0 50 Ambient Temperature (ºC) 90 10 100 Load Current (Amps) Load Current (Amps) 20 80 20 DC100D80 0.5°C/W 5°C/W 40 70 30 Ambient Temperature (ºC) 2°C/W 60 0 30 80 40 50 DC100D40 5 20 60 30 40 2°C/W 10 DC100D60 20 30 40 Ambient Temperature (ºC) 1°C/W 5°C/W 3°C/W Ambient Temperature (ºC) 15 100 100 20 20 0 50 90 40 100 Load Current (Amps) Load Current (Amps) 2 80 60 No Heat Sink (T) 5°C/W 4 70 80 DC100D20 No Heat Sink (T) 6 40 1.5°C/W Ambient Temperature (ºC) 8 60 0 20 20 30 50 DC60D100 40 100 10 20 40 0.5°C/W 5°C/W 3°C/W 60 DC100D10 5°C/W 30 Ambient Temperature (ºC) 0 40 10 100 Ambient Temperature (ºC) Load Current (Amps) 70 Load Current (Amps) Load Current (Amps) Load Current (Amps) 40 0 Load Current (Amps) 60 80 30 20 DC60D80 0.5°C/W 5°C/W 60 20 30 Ambient Temperature (ºC) 2°C/W 5ºC/W 0 20 Ambient Temperature (ºC) 1°C/W 3°C/W 40 Load Current (Amps) 8 0 16 2°C/W 20 Load Current (Amps) Load Current (Amps) 10 DC60D40 No Heat Sink (T) 5°C/W 20 30 40 50 60 70 80 90 100 80 60 40 20 0 20 30 40 Ambient Temperature (ºC) Complete specifications of these & other Crydom products available at: www.crydom.com 50 60 70 80 Ambient Temperature (ºC) 90 100 Derating Curves DC200D10 DC200D20 No Heat Sink (T) 5°C/W 2.5°C/W 8 6 4 2 15 10 5 0 0 20 30 40 50 60 70 80 90 30 40 Ambient Temperature (ºC) 50 60 70 80 90 1.5°C/W 3ºC/W 20 40 30 20 10 0 60 70 40 50 80 90 100 60 70 80 90 100 90 100 DC400D20 3°C/W 0.5°C/W 5°C/W 1.5°C/W 5ºC/W 20 8 6 4 2 0 50 30 Ambient Temperature (ºC) Load Current (Amps) Load Current (Amps) 50 40 10 100 10 30 20 DC400D10 1.5°C/W 60 20 30 Ambient Temperature (ºC) DC200D60 0.5°C/W 5ºC/W 0 20 100 3°C/W 40 Load Current (Amps) Load Current (Amps) Load Current (Amps) 1°C/W 20 10 Load Current (Amps) DC200D40 No Heat Sink (T) 3°C/W 15 10 5 0 20 30 40 50 60 70 80 90 100 20 30 40 Ambient Temperature (ºC) Ambient Temperature (ºC) 50 60 70 80 Ambient Temperature (ºC) DC500x60 0.7°C/W 1°C/W TABLE 3: Heat Sinks 5°C/W 3°C/W Load Current (Amps) 60 Crydom Part No. 50 HS501DR 40 HS301 / HS301DR Thermal Resistance [ ºC/W] 5 3 30 HS251 20 10 0 20 30 40 50 60 70 80 90 100 Ambient Temperature (ºC) 2.5 HS202 / HS202DR 2 HS201 / HS201DR 2 HS172 1.7 HS151 / HS151DR 1.5 HS122 / HS122DR 1.2 HS103 / HS103DR 1 HS101 1 HS073 0.7 HS072 0.7 HS053 0.5 HS033 0.36 HS023 0.25 General Notes (T) SSR metal base plate acting as heat sink, it must be exposed to free ambient air. Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 17 Surge Current Surge Current Graphics Surge Current Graphics: CW Series Surge Current Duty Factor CWxx10 Duty Factor (10%) (**) Duty Factor (20%) (**) Duty Factor (50%) (**) EXAMPLE 1 60 Surge Current (Amp) 400 Surge Current (Amp) AC Peak Single Pulse (*) 50 40 30 20 10 350 300 250 200 150 100 50 0 0.01 0 0.1 1 10 100 0.1 1000 Surge Current (Amp) AC Peak Duty Factor 10% Duty Factor 20% 1 10 1 10 1 10 1 10 600 500 400 300 200 100 0 0.01 Pulse Wide x 100 (%) Period CWxx50 800 Surge Current (Amp) AC Peak Pulse Wide = 0.1 Surge Duration (sec) For Pulse Wide Modulation applications select the curve according duty factor and pulse duration as following. Duty Factor 10 CWxx25 Period Duty Factor 50% 1 Surge Duration (sec) Surge Duration (msec) (*) for Single Surge Pulse Tc=40°C ;Tj 175°C (**) for Repetitive Surge Pulse Tc=40°C ;Tj 130°C 700 600 500 400 300 200 100 0 0.01 0.1 Surge Duration (sec) Surge Current Single Pulse CWxx90 Single Pulse (Ƈ) 1500 Surge Current (Amp) AC Peak EXAMPLE 2 Surge Current (Amp) 20 15 10 5 0 0.01 0.1 1 10 1200 900 600 300 0 0.01 0.1 Surge Duration (sec) Surge Duration (sec) (Ƈ) for Single Surge Pulse Tc=25°C ;Tj 150°C. For Single Surge Pulse, AC Output [CW & CL series]: Tc=25ºC; Tj=125ºC CWxx125 For AC Output SSRs, AC Rms value of surge current equals the peak value divided by √2 (1.414). Surge Current (Amp) AC Peak 2000 1500 1000 500 0 0.01 0.1 Surge Duration (sec) 18 Complete specifications of these & other Crydom products available at: www.crydom.com Surge Current Surge Current Graphics: CL Series CL240x10 CL240x05 120 80 Surge Current (Amp) Surge Current (Amp) 90 70 60 50 40 30 20 10 0 100 80 60 40 20 0 0.01 0.1 1 0.01 10 0.1 1 10 Surge Duration (sec) Surge Duration (sec) Surge Current Graphics: DC60 Series DC60Sx3 DC60Sx5 20 Surge Current (Amp) Surge Current (Amp) 20 15 10 5 0 0.1 1 10 100 15 10 5 0 1000 0.1 1 Surge Duration (msec) 10 100 1000 Surge Duration (msec) DC60Sx7 Surge Current (Amp) 20 15 10 5 0 0.1 1 10 100 1000 Surge Duration (msec) Surge Current Graphics: DC06D Series DC06D80 350 250 300 Surge Current (Amp) Surge Current (Amp) DC06D60 300 200 150 100 50 250 200 150 100 50 0 0 0.1 1 10 100 1000 0.1 1 Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] 10 100 1000 Surge Duration (msec) Surge Duration (msec) EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 19 Surge Current Surge Current (Amp) DC06D100 500 450 400 350 300 250 200 150 100 50 0 0.1 1 10 100 1000 Surge Duration (msec) Derating Curves: Series 1-DC & 1-DCL D1D07 D1D12 60 80 70 Surge Current (Amp) Surge Current (Amp) 50 40 30 20 10 60 50 40 30 20 10 0 0 0.1 1 10 100 0.1 1000 1 D1D20 Surge Current (Amp) Surge Current (Amp) 250 80 60 40 20 200 150 100 50 0 0.1 1 10 100 1000 0.1 1 Surge Duration (msec) D1D60 Surge Current (Amp) 250 200 150 100 50 0 1 10 100 1000 100 1000 100 1000 D1D80 300 0.1 10 Surge Duration (msec) 350 Surge Current (Amp) 1000 D1D40 0 100 600 550 500 450 400 350 300 250 200 150 100 50 0 0.1 1000 1 10 Surge Duration (msec) Surge Duration (msec) D1D100 D2D07 800 50 600 40 Surge Current (Amp) Surge Current (Amp) 100 300 100 400 200 30 20 10 0 0 0.1 1 10 Surge Duration (msec) 20 10 Surge Duration (msec) Surge Duration (msec) 100 1000 0.1 1 10 Surge Duration (msec) Complete specifications of these & other Crydom products available at: www.crydom.com Surge Current D2D12 D2D40 60 Surge Current (Amp) Surge Current (Amp) 70 50 40 30 20 10 0 0.1 1 10 100 240 220 200 180 160 140 120 100 80 60 40 20 0 1000 0.1 1 Surge Duration (msec) D4D07 100 1000 100 1000 100 1000 D4D12 50 70 60 40 Surge Current (Amp) Surge Current (Amp) 10 Surge Duration (msec) 30 20 10 50 40 30 20 10 0 0 0.1 1 10 100 0.1 1000 1 Surge Duration (msec) 10 Surge Duration (msec) D5D07 D5D10 40 70 Surge Current (Amp) Surge Current (Amp) 60 30 20 10 0 50 40 30 20 10 0 0.1 1 10 100 1000 0.1 1 Surge Duration (msec) 10 Surge Duration (msec) Derating Curves: SSC Series SSC1000 120 Surge Current (Amp) 100 80 60 40 20 0 0.1 1 10 100 1000 Surge Duration (msec) Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 21 Surge Current Derating Curves: PowerPlus DC Series DC60D10 DC60D20 150 125 Surge Current (Amp) Surge Current (Amp) 100 75 50 25 100 75 50 25 0 0 0.1 1 10 100 1000 0.1 1 Surge Duration (msec) 10 100 1000 100 1000 100 1000 100 1000 Surge Duration (msec) DC60D40 DC60D60 225 300 175 250 Surge Current (Amp) Surge Current (Amp) 200 150 125 100 75 50 200 150 100 50 25 0 0.1 1 10 100 0 1000 0.1 1 Surge Duration (msec) DC60D80 DC60D100 500 450 400 350 300 250 200 150 100 50 0 300 Surge Current (Amp) Surge Current (Amp) 350 250 200 150 100 50 0 0.1 1 10 100 1000 0.1 1 Surge Duration (msec) DC100D20 125 80 100 Surge Current (Amp) Surge Current (Amp) 100 60 40 20 75 50 25 0 0 0.1 1 10 100 1000 0.1 1 Surge Duration (msec) 10 Surge Duration (msec) DC100D40 DC100D60 350 300 300 250 Surge Current (Amp) Surge Current (Amp) 10 Surge Duration (msec) DC100D10 200 150 100 50 250 200 150 100 50 0 0 0.1 1 10 Surge Duration (msec) 22 10 Surge Duration (msec) 100 1000 0.1 1 10 Surge Duration (msec) Complete specifications of these & other Crydom products available at: www.crydom.com 100 1000 Surge Current DC100D100 800 Surge Current (Amp) Surge Current (Amp) DC100D80 600 550 500 450 400 350 300 250 200 150 100 50 0 600 400 200 0 0.1 1 10 100 0.1 1000 1 10 100 1000 Surge Duration (msec) Surge Duration (msec) DC200D10 DC200D20 175 125 Surge Current (Amp) Surge Current (Amp) 150 100 75 50 25 125 100 75 50 25 0 0 0.1 1 10 100 0.1 1000 1 Surge Duration (msec) 300 500 250 400 Surge Current (Amp) Surge Current (Amp) 100 1000 100 1000 100 1000 DC200D60 DC200D40 200 150 100 50 300 200 100 0 0 0.1 1 10 100 1000 0.1 1 Surge Duration (msec) 10 Surge Duration (msec) DC400D10 DC400D20 70 125 Surge Current (Amp) 60 Surge Current (Amp) 10 Surge Duration (msec) 50 40 30 20 10 0 100 75 50 25 0 0.1 1 10 100 1000 0.1 1 Surge Duration (msec) 10 Surge Duration (msec) DC500x60 Surge Current (Amp) 350 300 250 200 150 100 50 0 0.1 1 10 100 1000 Surge Duration (msec) Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] Asia Tel.: +86 (0) 21 6065 7725 e-mail: [email protected] 23 AMERICAS EUROPE, MIDDLE EAST & AFRICA ASIA United States & Canada Mexico Southern & Central Custom Sensors & Technologies (CST) 2320 Paseo de las Americas, Suite 201 San Diego, CA 92154 Sales Support: Tel.: +1 (877) 502 5500 Fax: +1 (619) 210 1590 [email protected] Technical Support: Tel.: +1 (877) 702 7700 [email protected] Custom Sensors & Technologies (CST) Calzada Zavaleta 2505-C Col Sta Cruz Buenavista C.P. 72150 - Puebla Sales Support: Tel. : +52 (222) 409 7000 Fax : +52 (222) 409 7810 [email protected] Custom Sensors & Technologies (CST) Alameda Rio Negro, 1030, 18º andar – Conjunto 1803 CEP: 06454-000 Barueri - São Paulo Brasil Tel.: +55 (11) 2505 7500 Fax: +55 (11) 2505 7507 United Kingdom Austria & Switzerland Germany Netherlands Custom Sensors & Technologies (CST) Everdene House, Deansleigh Road Wessex Fields, Bournemouth, Dorset BH7 7DU Sales Support Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Technical Support [email protected] Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Tel.: +49 (0) 180 3000 506 Fax: +49 (0) 180 3205 227 [email protected] Tel.: +31 (0) 71 582 0068 Fax: +31 (0) 71 542 1648 [email protected] Belgium Italy Tel.: +32 (0) 2 460 4413 Fax: +32 (0) 2 461 2614 [email protected] Tel.: +39 (0) 2 665 99 260 Fax: +39 (0) 2 665 99 268 [email protected] Middle East, Africa & Other European Countries France Spain Tel.: +33 (0) 810 123 963 Fax: +33 (0) 810 057 605 [email protected] China South Korea East Asia Pacific Custom Sensors & Technologies (CST) 11th floor Chang Feng International Tower 89 Yunling Road (East) Putuo District Shanghai, 200062 Sales Support Tel.: +86 (21) 8025 7166 Fax: +86 (21) 6107 1771 [email protected] Technical Support [email protected] Custom Sensors & Technologies (CST) 14F, Kbiz DMC Tower, 189, Seongam-ro, Mapo-gu, Seoul 121-904, South Korea Tel.: +82 2 2629 8312 Fax: +82 2 2630 9800 [email protected] Custom Sensors & Technologies (CST) 2F, No. 39, Ji-Hu Road Nei-Hu Dist. Taipei 114, Taiwan Tel.: +86 (21) 8125 7177 Fax: +86 (21) 6107 1771 [email protected] [email protected] India Custom Sensors & Technologies (CST) 4th Floor, Trident Towers, No. 23, 100 Ft- Ashoka Pillar Road, 2nd Block, Jayanagar, Bangalore- 560011 Tel: +91 (80) 4113 2204 /05 Fax: +91 (80) 4113 2206 [email protected] © 2014 Crydom Inc., All Rights Reserved. CAT/CR/P2/EN Specifications are subject to change without prior notice. Crydom and the Crydom logo are registered trademarks of Crydom Inc. Distributed by : 11/2014 Rev.050415 Tel.: +34 902 876 217 Fax: +34 902 876 219 [email protected] Tel. : +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected]