ED Series The Global Expert in Solid State Relay Technology ED Series ABOUT US Crydom, a brand of Custom Sensors & Technologies (CST) and global expert in Solid State Relay Technology, has a distinguished record of providing high quality, world class Solid State Relay and Control Products for a variety of heating, lighting and motion control applications. Crydom products, coupled with unparalleled technical support, timely delivery and competitive pricing, provide Crydom’s clients with the innovative products and support necessary to succeed in today’s competitive and DIN RAIL OR PC MOUNTED PLUG-IN SOLID STATE RELAYS & SOCKETS “LIFEPLUS ED SERIES” PLUG IN SOLID STATE RELAYS Crydom’s new “LifePlus ED Series” of AC and DC Output Plug-in Solid State Relays are designed to replace industry standard 12 x 29 mm plug-in Electromechanical Relays. Crydom’s proven Solid State Relay fast paced global markets. Technology offers substantial performance advantages over traditional Crydom’s extensive selection of standard off-the-shelf products is greater life expectancy (>100 million operations), contactless high speed EMR switching solutions in many applications including significantly constantly being updated and expanded through its continuous improvement and aggressive new product development programs. Utilizing state of the art designs, materials and technology, Crydom offers a wide range of AC and DC output SSRs in industry standard Panel Mount, PCB Mount and DIN Rail packages, all meeting global safety and switching which eliminates contact bounce, arcing and resulting electrical noise, precise low power logic compatible control inputs, acoustically silent operation and high shock and vibration resistance. Available in a SPST N.O. configuration, the “LifePlus ED series” offer output ratings of either 3 or 5 Amps rms at 24 to 280 VAC, or 5 Amps DC standards agency requirements such as CE, RoHS, UL, IEC, etc. at 1 to 48 or 1 to 80 VDC, all at 40 °C ambient temperature. AC outputs Bolstered by four decades of Solid State Relay operations experience, outputs utilize high efficiency FETs, both technologies resulting in the Crydom also specializes and encourages adapted and incorporate Crydom’s proven Back-to-Back SCR technology while DC fully custom-designed SSR products for nearly any application where unique lowest possible on-state power dissipation and high surge current ratings which makes the “Crydom LifePlus” an excellent choice for applications specifications and optimized performance are critical for success. such as small Motors, Solenoids, Heaters and Lamps. Optically isolated Crydom’s modern purpose-built 100,000 square foot manufacturing 18 to 36 VAC and 90 to 140 VAC. facility houses all aspects of its ISO certified operation including Design and Development Engineering, Manufacturing Operations and Quality Assurance, Customer Service, Finance, Marketing and General Management, permitting close coordination of all aspects of Crydom’s activities. Applications Engineering and Sales support are both performed in the field to provide Crydom’s Customers with the unparalleled technical and commercial support. Following rigid design guidelines and standards, Crydom products have set the bench mark for SSR performance and reliability world wide. In addition to award winning designs, Crydom has acquired an impressive list of patents related to SSRs and Solid State Controls, while continuing to develop new circuit and technology-related inventions as part of control inputs available include 3 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC, Cydom’s “LifePlus ED Series” are UL 508 recognized for general purpose, motor control and pilot duty applications, and compliant to IEC 62314 LC-A resistive and LC-B inductive application requirements. They are also CE certified to the IEC Low Voltage Directive and compliant to the IEC EMC directive. “LIFEPLUS ED SERIES” DIN RAIL AND PCB MOUNT ACCESSORY SOCKETS The “LifePlus ED Series” includes accessory sockets accepting the Crydom ED Series SSRs and industry standard 12 x 29 mm plug-in relay packages. One version socket fits standard 35 mm DIN rail while a second version is PCB mountable, allowing direct replacement of SPST N.O. extensive R&D programs. EMRs in both type installations. Equipped with screws for wire termination To learn more about Crydom SSR technology and products, or how an provide an easy means to install and utilize Crydom ED Series Solid State and a positive latch for relay retention, the “LifePlus ED Series” sockets alliance with Crydom can contribute to the success of your project, visit www.crydom.com or contact your authorized Crydom Distributor or Crydom Customer Service Representative today. Relays. Featuring all solid state construction, “LifePlus ED Series” SSRs and Sockets provide an excellent improvement in performance over traditional EMRs. For more information on “Crydom LifePlus” Series SSRs, contact the nearest Crydom Distributor, Representative or Local Crydom Sales Office, or visit our website at www.crydom.com. www.crydom.com ED Series ED Series AC Output Pluggable SSRs 12 x 29 mm industry standard plug-in package 3 & 5 Amps output power rating available 3 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC, 18 to 36 VAC & 90 to 140 VAC control input options available Plug in replacement of EMRs Convenient Quick Connect terminals for PCB or direct wiring Fits standard DIN rail & PCB mountable sockets, also available as accessories UL & IEC Resistive/Motor/Pilot Duty Ratings available LED input status indicator Zero Voltage for resistive loads and Random Turn-On for inductive loads versions available Output Specifications (A) ED24x3 ED24x5 24-280 VAC Operating Voltage Range (47-63 Hz) [Vrms] 600 Transient Overvoltage [Vpk] 0.1 Maximum Off-State Leakage Current @ Maximum Operating Voltage [mArms] 500 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 3 Maximum Load Current [Arms] 5 150 mA Minimum Load Current [Arms] 1 Cycle Surge Current (50/60 Hz) [Apk] 240 / 250 (C) Maximum I²t for Fusing (50/60Hz) [A² sec] 285 / 260 600 / 625 (C) 1780 / 1620 ≤1.1 Maximum On-State Voltage Drop @ Rated Current [Vpk] 0.5 Minimum Power Factor (with Maximum Load) UL 508 Resistive Load @ 280 VAC [Arms] 3 5 UL 508 Motor Controller @ 240 VAC [HP] ¼ ½ UL 508 Pilot Duty @ 120 V (Make/Break) [Amps] (B) 15 / 1.5 UL 508 Pilot Duty @ 240 V (Make/Break) [Amps] (B) IEC 62314 LC-A @ 280 VAC [FLA] 7.5 / 0.75 IEC 62314 LC-B @ 240 VAC [Kw] 3 5 0.37 0.55 Input Specifications (A) ED24Dx ED24Cx ED24Fx ED24E5 ED24B5 Control Voltage Range 3-15 VDC 18-32 VDC 48-72 VDC 18-36 VAC 90-140 VAC Minimum Turn-On Voltage Must Turn-Off Voltage 3 VDC 18 VDC 48 VDC 18 VAC 90 VAC 1.9 VDC 10.5 VDC 24 VDC 10 VAC 48 VAC Maximum Reverse Voltage [VDC] 6 Minimum Input Current (for on-state) Maximum Input Current Nominal Input Impeadance [Ohm] 3.8 mA @ 3 VDC 3.8 mA @ 18 VDC 3.8 mA @ 48 VDC 3.8 mA @ 18 VAC 3.2 mA @ 90 VAC 33.8 mA @ 15 VDC 6.9 mA @ 32 VDC 5.8 mA @ 72 VDC 8.5 mA @ 36 VAC 4.9 mA @ 140 VAC 500 4.8 K 12.5 K 4.5 K 28 K Maximum Turn-On Time [msec] (Zero Voltage) 1/2 Cycle (D) Maximum Turn-Off Time [msec] 1/2 Cycle (E) General Specifications (A) ED24x3 ED24x5 Dielectric Strength, Input to Output to Base (50/60Hz) [Vrms] 3750 Minimum Insulation Resistance @ 500 VDC 109 Maximum Capacitance, Input to Output [pF] 10 Ambient Operating Temperature Range [°C] -30 to 80 Ambient Storage Temperature Range [°C] IP ratings -40 to 125 IP00 / IP10 when mounted in PCBSED / DRSED socket or equivalent Housing Material PBT 30% GF, UL 94 V0 Terminal Finish Sulfamate Nickel LED Status Indicator for Control Input Weight (typical) [oz] (gr) On: Green 0.705 (20) 1.06 (30) Humidity Quick Connect / 0.187 x 0.02 (4.75 x 0.51) General Notes Derating Curves (F, G) (A) All parameters at 25ºC unless otherwise specified. (B) Pilot duty ratings, per UL 508, available for ED24D3, ED24D5 & ED24E5. (C) TJ = 25°C, time: 20 msec. (50 Hz) / 16.6 msec. (60 Hz). (D) Turn-On time for Random-type AC Output (R suffix) is 0.1 msec for DC Control Models, and for AC Control Models is 20 msec. (E) Turn-Off Time for AC output versions with AC control is 30 msec. (F) UL ratings are for relays only. To achieve maximum ratings, there must be a minimum spacing of 0.67 in (≥17 mm) between the devices in free air. (G) 100% Duty Cycle. ED24xxx 6.0 Load Current (Amps) Terminal type / size [in] (mm) 5 to 85% HR 5.0 4.0 3.0 2.0 1.0 0 10 5 Amps 3 Amps 20 30 40 50 Ambient Temperature (ºC) Complete specifications of these & other Crydom products available at: www.crydom.com 60 70 80 ED Series Wiring Diagram (J,K) Part Number Nomenclature Series ED Output Voltage 06: 1-48 VDC (5 Amps only) 10: 1-80 VDC (5 Amps only) 24: 24-280 VAC 24 C RELAY (L,M) Part no.: ED series Operational Current 3: 3 Amps (not available with B & E suffixes) 5: 5 Amps 5 (Bottom view) Load 4 R 4 (11) 2 Switching Mode Blank: Zero Voltage Turn-On (AC Output only) R: Random Turn-On (AC Output only) Control Voltage B: 90-140 VAC C: 18-32 VDC D: 3-15 VDC (H) E: 18-36 VAC F: 48-72 VDC 3 (14) 3 1 5 1 (A1) Required for valid part number For options only and not required for valid part number 5 (A2) DC/AC Control Voltage Mechanical Dimensions Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] SOCKET Part no.: PCBSED 1.10 [27.9] .99 [25.0] 3 4 2 1.47 [37.4] AC Output: 3 Amps DC Output: C, D & F suffix .82 [20.8] 3 (14) Load AC Output: 5 Amps DC Output: B, E suffix (Bottom view) 1 5 5 (A2) 1 (A1) .02 [0.5] .24 [6.1] .30 [7.6] .12 [3.0] .20 [5.1] .19 [4.8] SOCKET (N,P) Part no.: DRSED .21 [5.3] (Top view) 4 (11) .10 [2.5] 1 4 (11) 4 2 2 4 3 (14) 3 3 Load 5 .39 [9.9] .50 [12.7] 1.14 [29.0] (H) 5-15 VDC range for ED06/10D5 (J) DC inductive loads must be diode suppressed. (K) No grounding required. (L) For sockets intended for AC input control voltage, the AC line can be wired to either DRSED socket terminal 1 (A1-) or terminal 5 (A2+). Proper polarity must be observed for DC input control voltage sockets being terminal 5 (A2+) positive with respect to terminal 1 (A1-). (M) For AC loads, the AC line can be wired to either DRSED socket terminal 4 (11) or terminal 3 (14). The AC load may also be wired on either the line or neutral side of the SSR. For DC loads, the proper polarity must be observed for the power supply, load and DRSED socket with terminal 3 (14) being positive with respect to terminal 4 (11). (N) Minimum wire strip lenght 0.197 in (5 mm), maximum 0.256 in (6.5 mm) for wiring socket DRSED. (P) Input / Output terminals screw M3 Combo Drive for socket DRSED. 5 (A2) 1 (A1) ED Series Accessories DRSED PCBSED DIN Rail Mountable Socket Part no.: DRSED Fingersafe IP10 DIN rail mountable socket to mount ED series relays onto standard 35 mm DIN rail. Rated at 250 V AC/DC, 12 Amps. The DRSED includes M3 Combo screws. Questions? Call or e-mail: America Tel.: +1 (877) 502 5500 e-mail: [email protected] EMEA Tel.: +44 (0) 1202 606030 e-mail: [email protected] PC Board Mountable Socket Part no.: PCBSED PC Board mountable socket for ED series relays. Rated at 250 V AC/DC, 12 Amps. Suggested Pin-out hole diameter: 1.0 mm Asia Tel.: +86 (0) 21 2401 7766 e-mail: [email protected] ED Series ED Series DC Output Pluggable SSRs 12 x 29 mm industry standard plug-in package 5 Amps output power rating 5 to 15 VDC, 18 to 32 VDC, 48 to 72 VDC, 18 to 36 VAC & 90 to 140 VAC control input options available Plug in replacement of EMRs Convenient Quick Connect terminals for PCB or direct wiring Fits standard DIN rail & PCB mountable sockets, also available as accessories UL & IEC Resistive/Motor Ratings available LED input status indicator Output Specifications (A) ED06x5 Absolute maximum operating voltage [VDC] Rated Voltage [VDC] EDxxD5 ED10x5 60 100 1-48 1-80 EDxxC5 EDxxF5 EDxxE5 EDxxB5 N/A 20 (Q) Maximum Off-State Leakage Current @ Rated Voltage [µA] Maximum Load Current [A] 5 Minimum Load Current [A] 0.1 60 (R) Maximum Surge Current (10ms) [ADC] ≤ 0.3 Maximum On-State Voltage Drop @ 40ºC Rated Current [VDC] 0.034 (S) Maximum On-State Resistance (RDS-ON) [Ohm] Maximum PWM (Hz) 500 500 500 N/A UL 508 Resistive Load @ Rated Voltage [A] 5 5 5 5 5 UL 508 Motor Controller@ Rated Voltage [FLA] 2 2 2 1.5 1.5 IEC 60947-4-1 DC-1@ Rated Voltage [ADC] 5 5 5 5 5 IEC 60947-4-1 DC-3@ Rated Voltage [FLA] 5 5 5 5 5 Input Specifications (A) EDxxD5 EDxxC5 EDxxF5 EDxxE5 EDxxB5 Control Voltage Range 5-15 VDC 18-32 VDC 48-72 VDC 18-36 VAC 90-140 VAC Minimum Turn-On Voltage 5 VDC 18 VDC 48 VDC 18 VAC 90 VAC 1.3 VDC 2.0 VDC 4.0 VDC 4.0 VAC 11 VAC 11 mA @ 5 VDC 10.7 mA @ 18 VDC 10.8 mA @ 48 VDC 12 mA @ 18 VAC 7.3 mA @ 90 VAC 42.8 mA @ 15 VDC 19.7 mA @ 32 VDC 16.3 mA @ 72 VDC 25.3 mA @ 36 VAC 10.9 mA @ 140 VAC 350 1.6 K 4.4 K 1.5 K 12.5 K EDxxE5 EDxxB5 Must Turn-Off Voltage Maximum Reverse Voltage [VDC] 3 Minimum Input Current (for on-state) Maximum Input Current Nominal Input Impeadance [Ohm] Maximum Turn-On Time [msec] 0.6 Maximum Turn-Off Time [msec] 0.3 General Specifications (A) EDxxD5 EDxxC5 EDxxF5 Dielectric Strength, Input/Output/Base (50/60Hz) [Vrms] 2500 Minimum Insulation Resistance @ 500 VDC 109 Maximum Capacitance, Input/Output [pF] 10 Ambient Operating Temperature Range [°C] -30 to 80 Ambient Storage Temperature Range [°C] -40 to 125 Housing Material PBT 30% GF, UL 94 V0 Terminal Finish IP ratings Sulfamate Nickel IP00 / IP10 when mounted in PCBSED / DRSED socket or equivalent LED Status Indicator for Control Input On: Green Weight (typical) [oz] (gr) 0.705 (20) 0.705 (20) 0.705 (20) 1.06 (30) 1.06 (30) 5 to 85% HR Humidity Terminal type / size [in] (mm) Quick Connect / 0.187 x 0.020 (4.75 x 0.51) General Notes Derating Curves (T,G) To view available Installation Sheet scan the QR code with your smartphone or visit www.crydom.com ED06x5 & ED10x5 6.0 Load Current (Amps) (A) All parameters at 25ºC unless otherwise specified. (Q) Output Voltage is Maximum Operating Voltage, Control Voltage = 0 V, TJ = 25°C (R) Output Voltage = 2.5 VDC (S) At maximum load current (T) UL ratings are for relays only. To achieve maximum ratings, there must be a minimum spacing of 0.63 in (≥16 mm) between the devices in free air (G) 100% Duty Cycle 5.0 4.0 3.0 2.0 1.0 0 10 20 30 40 50 Ambient Temperature (ºC) Complete specifications of these & other Crydom products available at: www.crydom.com 60 70 80 AMERICA EUROPE, MIDDLE EAST & AFRICA United States & Canada Crydom Inc 2320 Paseo de las Americas, Suite 201 San Diego, CA 92154 Sales Support: Tel.: +1 (877) 502 5500 Fax: +1 (619) 210 1590 [email protected] Technical Support: Tel.: +1 (877) 702 7700 [email protected] United Kingdom Crydom SSR Ltd Arena Business Centre Holyrood, Close Poole, Dorset BH17 7FJ Sales Support Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Tech Support [email protected] Mexico American Countries CST Latinoamerica Alameda Rio Negro, 1030, 18º andar – Conjunto 1803 CEP: 06454-000 Barueri - São Paulo Brasil Tel.: +55 (11) 2505 7500 Fax: +55 (11) 2505 7507 [email protected] Austria & Switzerland Italy Tel.: +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] Tel.: +39 (0) 2 665 99 260 Fax: +39 (0) 2 665 99 268 [email protected] Belgium Spain Tel.: +32 (0) 2 460 4413 Fax: +32 (0) 2 461 2614 [email protected] Tel.: +34 902 876 217 Fax: +34 902 876 219 [email protected] France Netherlands Tel.: +33 (0) 810 123 963 Fax: +33 (0) 810 057 605 [email protected] Tel.: +31 (0) 71 582 0068 Fax: +31 (0) 71 542 1648 [email protected] Germany Middle East, Africa & Other European Countries Tel.: +49 (0) 180 3000 506 Fax: +49 (0) 180 3205 227 [email protected] ASIA PACIFIC China & Hong Kong Custom Sensors & Technologies Asia (Shanghai) Ltd. 13th floor Chang Feng International Tower 89 Yunling Road (East) Putuo District Shanghai, 200062 Sales Support Tel.: +86 (0) 21 6065 6699 Fax: +86 (0) 21 6065 7749 [email protected] Tech Support [email protected] Taiwan Specifications are subject to change without prior notice. Crydom and the Crydom logo are registered trademarks of Crydom Inc. 05/2011 Tel. : +44 (0) 1202 606030 Fax: +44 (0) 1202 606035 [email protected] India Custom Sensors & Technologies 2F, No. 39, Ji-Hu Road Nei-Hu Dist. Taipei 114 Tel: +886 2 8751 6388 Fax: +886 2 2657 8725 [email protected] CST Sensors India Pvt Ltd Unit 1301 and 1302 Prestige Meridian II 30 M.G.Road, Bangalore-560001 Tel: +91 (80) 4113 2204/05 Fax: +91 (80) 4113 2206 [email protected] South Korea South East Asian & Pacific Countries Custom Sensors & Technologies 2F, Jeil Bldg., 94-46 Youngdeungpo-dong 7-ga Youngdeungpo-gu, Seoul, 150-037 Tel.: +82 2 2629 8312 Fax: +82 2 2629 8310 [email protected] CAT/CR/LP/EN © 2011 Crydom Inc., All Rights Reserved. Southern & Central Automatismo Crouzet S.A. de C.V. Calzada Zavaleta 2505-C Col Sta Cruz Buenavista C.P. 72150 - Puebla Sales Support: Toll free: 01 800 087 6333 Tel. : +52 (222) 409 7000 Fax : +52 (222) 409 7810 [email protected] Technical Support: Toll free: 01 800 838 3736 Distributed by : Custom Sensors & Technologies 2F, No. 39, Ji-Hu Road Nei-Hu Dist. Taipei 114, Taiwan Tel.: +886 2 8751 6388 Fax: +886 2 2657 8725 [email protected]