DP系列接触器

DP Series
PART NUMBER NOMENCLATURE (E)
DC Load Reversing Solid State Contactors
Crydom’s advanced DC Switching Technology is now conveniently packaged in a High Power
“H-Bridge” configuration with optional Soft Start/Ramp Up, Soft Stop/Ramp Down & Brake
features for use in DC Load Reversing applications including motors, brakes, clutches, electro
magnets, solenoids, plating baths and electrolytic cells. The DP Series Solid State DC Reversers
are an all-solid-state design with 2.5 Kv Optical Isolation and incorporate low dissipation power
FETs for fast and efficient Load control.
Series
DP
4R
SB
D
60
Function
4R: 4 Channel DC Reversing
40
Rated Operating Voltage
60: 48 VDC
Convenient FET switches in H-bridge configuration
Built-in protective Forward/Reverse interlock function
UL & IEC ratings for general use & Motor loads
LED Status indicators for Operating Modes
H
Thermal Pad
Blank: Not Included
H: Included
DERATING CURVES (B)
70
Please read all installation instructions before using your DP Series Solid State Contactor (SSC).
60
Choose one of the two mounting options and follow the instructions.
Mounting on Heat Sink
Select adequate heat sink (see thermal derating
curves). (B)
l pad
Therma
Be sure to use thermal pad or grease between the
SSC and the selected heat sink.
Load Current (Amps)
MOUNTING INSTRUCTIONS (A)
DP Series Contactor mounting slots have a diameter
of 0.2 in (5.0 mm). Four screws are needed (not
included) to mount the SSC onto heat sink (See Fig.
1). Choose screw length considering the mounting
surface and that DP Series baseplate thickness is
0.125 in (3.2 mm).
B
Operational Current
20: 20 Amps
40: 40 Amps
60: 60 Amps
Required for valid part number
For options only and not required for valid part number
FEATURES
Stop Mode
Blank: Stop Mode matches Start Mode
B2: Dynamic Brake, 0.2 sec
B5: Dynamic Brake, 0.5 sec
B8: Dynamic Brake, 0.8 sec
B: Dynamic Brake, Continuous
Start Mode
Blank: Start
SA: Soft Start/Ramp Up, 0.2 sec Control Voltage
SB: Soft Start/Ramp Up, 0.5 sec D: 4.5-15 VDC
E: 18-32 VDC
SC: Soft Start/Ramp Up, 1 sec
DP4Rxx60x60xx
50
DP4Rxx60x40xx
40
30
DP4Rxx60x20xx
20
10
0
20
30
40
50
60
70
80
Ambient Temperature (ºC)
TABLE 1
fig. 1 DP Series SSC
mounted on HS053 heat sink (A)
DP Series
Part No.
Before applying full torque tighten down all 4 screws until they contact the baseplate.
Then, tighten them to 20 in-lbs (2.2 Nm) starting with one immediately followed by the one
in the diagonally opposite corner. After the first 2 screws are completely tightened,
proceed tightening the remaining 2 screws.
Required Heat Sink Crydom Heat Sink
Part No.
[ºC/W]
DP4Rxx60x20xx
DP4Rxx60x40xx
1.5
1.0
HS103/HS103DR
HS103/HS103DR
DP4Rxx60x60xx
0.5
HS053
For optimal thermal performance heat sink fins should be oriented vertically to natural
airflow.
Mounting on Panel
Locate the panel section on which the DP Series SSC will be mounted. Panel mount
surface must provide adequate heat sinking capability. (B)
Be sure to use thermal pad or grease between the SSC and the panel.
DP Series Contactor mounting slots have a diameter of 0.2 in (5.0 mm). Four screws are
needed (not included) to mount the SSC onto panel. Choose screw length considering the
mounting surface and that DP Series baseplate thickness is 0.125 in (3.2 mm).
TABLE 2
Status Functions
Green LED (Forward)
Yellow LED (Reverse)
Initial Logic Supply Voltage On
Flash Twice
Flash Twice
Forward ON
ON
OFF
Reverse ON
OFF
ON
Flash Once
Flash Once
Flash 3x Intermittently
Flash 3x Intermittently
Dynamic Brake
Interlocking
TABLE 3
Before applying full torque tighten down all 4 screws until they contact the baseplate.
Then, tighten them to 20 in-lbs (2.2 Nm) starting with one immediately followed by the one
in the diagonally opposite corner. After the first 2 screws are completely tightened,
proceed tightening the remaining 2 screws.
WIRING DIAGRAM (C)
DC Power Supply
Output Terminal
Maximum Torque
lbs in (N m)
Wire Size
for Max. Ratings
AWG (mm2)
Screw / Clamp Combo Type 10-32
20 (2.2)
12 (3.3)
DP4Rxx60x40xx
Hex Screw Type 1/4-20 with lock washers
25 (2.8)
8 (8.4)
DP4Rxx60x60xx
Hex Screw Type 1/4-20 with lock washers
25 (2.8)
6 (13.3)
DP Series
Part No.
DP4Rxx60x20xx
TABLE 4
Accessories
1/-
DC POWER SUPPLY SIDE
4 / L2
LOAD SIDE
+VCC
2/+
5
6
7
8
(D)
3 / L1
Motor
GND
Resistance
HK1
HS053
HS103
HS103DR
HSP-3
HSP-5
TRM1
TRM6
DP4Rxx60x20xx
+FWD
DP4Rxx60x40xx
+REV
DP4Rxx60x60xx
(A)
(B)
(C)
(D)
(E)
DC
Cell
DP Series
Part No.
See compatible accessories in TABLE 4.
For maximum ratings use heat sink ratings in TABLE 1.
Terminal (3/L1) is (+) during Forward operation. Terminal (4/L2) is (+) during Reverse operation.
Suggested Input Mating Connector/Plug : Crimp Housing, Positive Latch (Molex 050579404).
For a complete description of available Operating Modes, see definitions on reverse side of this sheet.
Rev. 060211
OPERATING MODES
Start: When either FWD or REV Control signal is applied, and after Control Signal Validation Delay, DC power
supply on terminals 1/- and 2/+ is directly connected to Load at terminals 3/L1 and 4/L2 with a polarity according
to the control signal. The start option can be combined with Stop and/or Dynamic Brake options.
the Load will remain continuously de-energized waiting for a new FWD or REV Control signal. Soft Stop/Ramp
Down time is tied to Soft Start/Ramp Up time selected by SA, SB and SC suffixes and can be combined with
Soft Start/Ramp Up only.
Stop: Load is disconnected from DC power supply. All FET switches (S1, S2, S3 & S4) inside the DP Series SSC are
turned off. This simple Stop option is available only in combination with the simple Start option (suffix Blank).
Dynamic Brake: It could be used as a modified Stop where the FET switches inside the DP Series SSC are
arranged in such a way that they provide a path for the Load Current to keep flowing after the DC power supply
has been disconnected. This mode allows for energy stored in some type of loads to be discharged. i.e. back
EMF on DC motors. Timing for Dynamic Brake is selected by suffixes B2, B5, B8 and B where the latest will
keep the braking or discharging path enabled for as long as FWD and REV Control signals are removed.
Soft Start/Ramp Up: It is a modified Start where the DC power supply is connected to the load using a 200 Hz pulse
width modulation with a duty cycle going from 10% to 100%. Soft Start/Ramp Up time is defined by SA, SB and SC
suffixes. After Soft Start/Ramp Up time is elapsed, the Load will remain continuously energized for as long as FWD
or REV Control signal is applied. This option can be combined with Soft Stop/Ramp Down and Dynamic Braking
modes, but not with simple Stop.
Soft Stop/Ramp Down: It is a modified Stop where the DC power supply is disconnected from the Load using a 200
Hz pulse width modulation with a duty cycle going from 100% to 0%. After Soft Stop/Ramp Down time is elapsed,
Interlock: It will shut down all FET switches inside the DP Series SSC within 0.2 sec after both control signals
FWD and REV are applied at the same time. An Interlock condition will trigger a modified Stop such as Soft
Stop/Ramp Down or Dynamic Brake whenever an option has been selected.
Control Signals
+ VFWD
Forward Control
0
+ VREV
Reverse Control
0
Load Voltage Signals (F)
S1, S4
Start
Stop
DP4R60xxx
S1, S4
3 / L1 = +
S2, S3
Int : Interlock
0
- VDCS
t : Control Signal Validation Delay
4 / L2 = +
= 0.2 sec, except for
t
t
S1, S4
Start
Dynamic Brake
DP4R60xxxBx
S2, S3
+ VDCS
S3, S4
Int
t
t
t1
+ VDCS
Int
t1 : 0.15 sec Break-before-make
t1
delay
tB : Dynamic Brake time
0
- VDCS
B2: 0.2 sec
t
t 1 tB
S1, S4
t
Int
t
t1 tB
S1, S4
S2, S3
t
Int
B: Continuous
tSP : Soft Stop/Ramp Down time = tST
tST : Soft Start/Ramp Up time
t
tST
tSP
S1, S4
t
S3, S4
Int
t
tST
tSP
t
t1
Soft Start/Ramp Up + VDCS
Dynamic Brake
0
DP4RSx60xxxBx
- VDCS
B5: 0.5 sec
B8: 0.8 sec
S3, S4
Soft Start/Ramp Up + VDCS
Soft Stop/Ramp Down 0
DP4RSx60xxx
- VDCS
Start / Stop (0.025 sec)
Int
SA: 0.2 sec
SB: 0.5 sec
SC: 1 sec
t1
VDCS: VDC power supply
VFWD: Forward Control Signal
VREV: Reverse Control Signal
t
tST
t1
tB
t
Int
t
tST
t1
tB
t
Int
Rev. 060211
(F) Load voltage signals shown are typical of a DC motor, behavior may change for other load types.