RoHS ACT13 Current Sensing Transformer Dimensions: (MM) 37.5 0.3 13 0.3 L K 14 0.3 39 0.3 1 2 4 3 S 4 F 1 2 25.4 0.3 3 6 1 Bottom View 1.0 33 0.3 13 0.3 Front View Left View Features Part • Mini-Precision Current Transformer Number • Good linearity over the entire range • Ideal for Current Measurement, Monitoring ACT13-30-012-_-100 & Protection Applications ACT13-30-015-_-100 • Standard Input Current 30-120A ACT13-50-020-_-100 • Frequency 50Hz-400Hz ACT13-50-025-_-100 • Custom designs available. ACT13-80-032-_-100 • Standard accuracy 0.1%,0.2%,0.5% • ANSI C57.13 and IEC60044-1 Standards ACT13-80-040-_-100 • Constructed using UL approved materials ACT13-100-050-_-100 Turns Accuracy (%) 2500 Input Current (A) Output Current (mA) Load Resistor (Ω) 0.1,0.2,0.5 30 12 100 2000 0.1,0.2,0.5 30 15 100 2500 0.1,0.2,0.5 50 20 100 2000 0.1,0.2,0.5 50 25 100 2500 0.1,0.2,0.5 80 32 100 2000 0.1,0.2,0.5 80 40 100 2000 0.1,0.2,0.5 100 50 100 ACT13-100-040-_-100 2500 0.1,0.2,0.5 100 40 100 ACT13-120-060-_-100 2000 0.1,0.2,0.5 120 60 100 ACT13-120-048-_-100 2500 0.1,0.2,0.5 120 48 100 Allied * Electrical HI-Pot: 4KV/1MA/1MIN Insulation Resistance: 500mΩ @ 500VDC Operating Temp: - 40ºC ~ +85ºC Storage Temp: -45ºC ~ +90ºC * *Specify desired accuracy by inserting code as follows: “01” for 0.1%, “02” for 0.2%, and “05” for 0.5%. All specifications subject to change without notice. K Physical 1 Weight: Approximately 50g RL L 2 note: 1. Primary current direction from K to L 2. Secondary current directions from S(1) to F(2) 3. RL: Output load resistance 949-356-1780 ALLIED COMPONENTS INTERNATIONAL 01/05/2016 www.alliedcomponents.com