RoHS ACT05 Current Sensing Transformer Dimensions: (MM) 17.8 10 epoxy 17.7 5.7 Bottom view 6±1 2(F) 0.6 1(S) 10.0 0.3 Left view Front view Features • Mini-Precision Current Transformer • Good linearity over the entire range • Ideal for Current Measurement, Monitoring & Protection Applications • Standard Input Current 5-20A • Frequency 50Hz-400Hz • Custom designs available. • Standard accuracy 0.2%,0.5%,1% • ANSI C57.13 and IEC60044-1 Standards • Constructed using UL approved materials Turns Accuracy (%) ACT05-5-005-_ 500 ACT05-10-010-_ Load Resistor (Ω) Input Current (A) Output Current (mA) 0.2,0.5,1 5 5 10 500 0.2,0.5,1 10 10 10 ACT05-10-005-_ 500 0.2,0.5,1 10 5 10 ACT05-15-015-_ 500 0.2,0.5,1 15 15 10 1000 0.2,0.5,1 20 20 10 Allied Part Number * ACT05-20-020-_ * ** *Specify desired accuracy by inserting code as follows: “02”=0.2%, “05”=0.5% and “10”=1.0%. **Load Resistor not included in part. All specifications subject to change without notice. Electrical HI-Pot: 4KV/1MA/1MIN Insulation Resistance: 500mΩ @ 500VDC Operating Temp: - 40ºC ~ +85ºC Storage Temp: -45ºC ~ +90ºC K 1 RL Physical L Weight: Approximately 10g 2 note: 1. Primary current direction from K to L 2. Secondary current directions from S(1) to F(2) 3. RL: Output load resistance 949-356-1780 ALLIED COMPONENTS INTERNATIONAL 01/05/2016 www.alliedcomponents.com