datasheet

SKYPER 12 press-fit C 450A
Absolute Maximum Ratings
SKYPER
®
Symbol
Conditions
Values
Unit
Vs
Supply voltage primary
ViH
Input signal voltage (HIGH)
15
V
Vs + 0.4
V
ViL
Input signal voltage (LOW)
GND - 0.4
V
IoutPEAK
Output peak current
15
A
IoutAVmax
Output average current
50
mA
fmax
Max. switching
frequency
85 °C
13
kHz
75 °C
20
kHz
1200
V
50
kV/µs
4000
V
8
µC
VCE
SEMIX P Plug & Play Driver
Board
Collector emitter voltage sense across
the IGBT
dv/dt
Rate of rise and fall of voltage
secondary to primary side
Order Nr. L5066902
Visol IO
Insulation test voltage input - output
(AC, rms, 2s)
Qout/pulse
Max. rating for output charge per pulse
SKYPER 12 press-fit C 450A
Top
Operating temperature
-40 ... 85
°C
Tstg
Storage temperature
-40 ... 85
°C
Features
Characteristics
Dynamic short circuit detection with
SoftOff
Undervoltage protection prim/sec
Internal power supply
ROHS, UL recognized
20P – Second Source Interface
DC BUS up to 1200V
Typical Applications*
Solar inverters
Power supplies
Motor drives
Symbol
Conditions
min.
Vs
Supply voltage primary side
14.4
IS0
Supply current primary (no load)
typ.
max.
15
15.6
100
Supply current primary side (max.)
Unit
V
mA
350
mA
Vi
Input signal voltage on / off
VIT+
Input treshold voltage (HIGH)
8.6
10
V
VIT-
Input threshold voltage (LOW)
5
6.7
V
RIN
Input resistance (switching/HALT
signal)
Vs/0
V
30
kΩ
CIN
Input capacitance (switching signals)
1
nF
Remarks
VG(on)
Turn on output voltage
14.6
V
Environmental conditions please see
technical explanation
VG(off)
Turn off output voltage
-9
V
td(on)IO
Input-output turn-on propagation time
1
µs
td(off)IO
Input-output turn-off propagation time
1
µs
td(err)SCP
Error sec - prim propagation time
0.6
µs
td(err)HALT
Error primary - secondary side
propagation time
0.6
µs
tTD
Top-Bot interlock dead time
2
µs
tjitter
Signal transfer prim - sec (total jitter)
tSIS
Short pulse suppression
tPOR
Power-On-Reset completed
tpRESET
Error reset time
VCEstat
Reference voltage for VCE-monitoring
7.5
V
tbl
VCE monitoring blanking time
6.5
µs
Ttp
Over temperature protection level - not
assembled
25
ns
0.395
µs
0.15
0.03
s
ms
°C
RGon
Driver gate resistor at switch-on
1.306
Ω
RGoff
Driver gate resistor at switch-off
8.1
Ω
MTBF
Mean Time Between Failure Ta = 40°C
7.5
106h
Two channel driver
© by SEMIKRON
Rev. 5.0 – 19.04.2016
1
SKYPER 12 press-fit C 450A
Signal Connector
PIN
Signal
X10:01
reserved
Function
Specifications
X10:02
IF_PWR_GND
GND
To be connected to ground
X10:03
reserved
ERROR output
Open pin
X10:04
IF_PWR_GND
GND
To be connected to ground
X10:05
IF_PWR_15P
Drive power supply
Stabilised +15V±4%
X10:06
IF_PWR_GND
GND
To be connected to ground
X10:07
PRIM_nERROR_IN
ERROR input
LOW ( GND ) = External error
X10:08
IF_PWR_GND
GND
To be connected to ground
X10:09
IF_nERROR_OUT
ERROR_OUT
HIGH = NO ERROR ; open collector output;
Open pin
HIGH ( VP ) = No error
max. 30V / 10mA (external pull up resistor )
X10:10
IF_PWR_GND
GND
To be connected to ground
X10:11
IF_HB_TOP
Switching input (TOP)
15V CMOS logic LOW = TOP switch off;
HIGH = TOP switch on
X10:12
IF_PWR_GND
GND
To be connected to ground
X10:13
IF_nERROR_OUT
ERROR output
HIGH = NO ERROR ; open collector output;
max. 30V / 15mA ( external pull up resistor )
X10:14
IF_PWR_GND
GND
To be connected with ground
X10:15
IF_HB_BOT
Switching input (BOTTOM)
15V CMOS logic, LOW = BOT switch off;
X10:16
IF_PWR_GND
GND
X10:17
reserved
X10:18
IF_PWR_GND
HIGH = BOT switch on
X10:19
reserved
X10:20
IF_PWR_GND
2
To be connected to ground
To be connected to ground
GND
To be connected to ground
GND
To be connected to ground
To be connected to ground
Rev. 5.0 – 19.04.2016
© by SEMIKRON
SKYPER 12 press-fit C 450A
Safe Operating Area
This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, chapter IX.
*IMPORTANT INFORMATION AND WARNINGS
The specifications of SEMIKRON products may not be considered as guarantee or assurance of product characteristics
("Beschaffenheitsgarantie"). The specifications of SEMIKRON products describe only the usual characteristics of products to be expected in
typical applications, which may still vary depending on the specific application. Therefore, products must be tested for the respective
application in advance. Application adjustments may be necessary. The user of SEMIKRON products is responsible for the safety of their
applications embedding SEMIKRON products and must take adequate safety measures to prevent the applications from causing a physical
injury, fire or other problem if any of SEMIKRON products become faulty. The user is responsible to make sure that the application design is
compliant with all applicable laws, regulations, norms and standards. Except as otherwise explicitly approved by SEMIKRON in a written
document signed by authorized representatives of SEMIKRON, SEMIKRON products may not be used in any applications where a failure of
the product or any consequences of the use thereof can reasonably be expected to result in personal injury. No representation or warranty is
given and no liability is assumed with respect to the accuracy, completeness and/or use of any information herein, including without limitation,
warranties of non-infringement of intellectual property rights of any third party. SEMIKRON does not assume any liability arising out of the
applications or use of any product; neither does it convey any license under its patent rights, copyrights, trade secrets or other intellectual
property rights, nor the rights of others. SEMIKRON makes no representation or warranty of non-infringement or alleged non-infringement of
intellectual property rights of any third party which may arise from applications. Due to technical requirements our products may contain
dangerous substances. For information on the types in question please contact the nearest SEMIKRON sales office. This document
supersedes and replaces all information previously supplied and may be superseded by updates. SEMIKRON reserves the right to make
changes.
© by SEMIKRON
Rev. 5.0 – 19.04.2016
3