Product Change Notices PCN No.:20081110 Date: 11/19/2008 This is to inform you that a molding compound change will be made to the following product(s). This notification is for your information and concurrence. If you require data or samples to qualify this change, please contact AME, Inc. within 30 days of receiving of this notification. If we do not receive any response from you within 30 calendar days from the date of this notification, we will consider that you have accepted this PCN. If you have any questions concerning this change, please contact: PCN Originator: Name: Bill Chou Email: [email protected] Effective Year/Work Week of Changed Product: 0901 Description of Change (From): Molding compound with halogen ingredient for AME products. Description of Change (To): Molding compound without halogen ingredient for AME products, It will be labelled as HF (Halogen Free). Reason for Change: Comply with environmental policy. Qual/REL Report: Please see attached SOT-89 Green compound series SOT-223 Green compound series SOT-2x Green compound series SOP-8 Green compound series SC-70 Green compound series TO-92 Green compound series TO-220 Green compound series TO-252 Green compound series TO-263 Green compound series QPM018A-C REL - Green package- GP-A Reliability Report for Green Compound Series Product Approved by Prepared by Amy Shen Quality & Reliability Dept. Manager Eric Chen Quality & Reliability Dept. Engineer Conclusion: The green compound series product has successfully met AME’s reliability standard that is required on all AME, Inc products. Furthermore, QRA Dept. of AME, Inc monitors the reliability continuously to make sure that all series product will still meet AME’s reliability standard in the future. Table of Contents: Ⅰ、Package Reliability Test Result Ⅱ、IR-reflow Test Result Ⅰ、Package Reliability Test Result: For SOT-89, SOT-223, SOT-2x, SOP-8, SC-70, TO-92, TO-220, TO-252, TO-263 Green compound series Test Item Test Condition Sample Size(each) / Failures Result MSL TCT -65℃~150℃ 5Cycle 22 pcs / 0 pcs Level 3 45 pcs / 0 pcs Pass 45 pcs / 0 pcs Pass 45 pcs / 0 pcs Pass 45 pcs / 0 pcs Pass 125℃,24hrs 30/60 192 hours IR-reflow 3 cycles Peak Temp.= 260℃ (lead-free) IPC/JEDEC J-STD-020C HTS Precondition NOTE 1 Temp.=150℃ Duration=1000 hours Unbiased, Read at 1000 hours HAST Precondition NOTE 1 Temp.=130℃, R.H.=85% Duration=168 hours Unbiased, Read at 168 hours PCT Precondition NOTE 1 Temp.=121℃, R.H.=100% 2atm, Unbiased Duration=168 hours Read at 168 hours TCT Precondition NOTE 1 -65℃ ~ 150℃ 200 cycles Unbiased, Read at 200 cycles NOTE 1: TCT -65℃~150℃ 5Cycle, 125℃,24hrs, 30/60 192 hours + IR-reflow 3 cycles with Peak Temp.= 260℃ (lead-free). Ⅱ、IR-reflow Test Result: For SOT-89, SOT-223, SOT-2x, SOP-8, SC-70, TO-92, TO-220, TO-252, TO-263 Green compound series Test Item Test Condition Sample Size(each) / Failures Result IR-reflow See IR reflow Profile 22 pcs / 0 pcs Pass Perform 3 cycles test IR reflow Profile: Profile Feature Average Ramp-Up Rate (Tsmax to Tp) - Preheat Temperature Min (Tsmin) Temperature Max (Tsmax) Time (tsmin to tsmax) Time maintained above - Temperature (TL) - Time (tL) Peak/Classification Temperature (Tp) Time within 5℃ of actual Peak Temperature (tp) Ramp-Down Rate Time 25℃ to Peak Temperature Sn-Pb Eutectic Assembly Pb-Free Assembly 3℃/second max. 3℃/second max. 100℃ 150℃ 60~120 seconds 150℃ 200℃ 60~180 seconds 183℃ 60~150 seconds 217℃ 60~150 seconds 245℃ 260℃ 10~30 seconds 20~40 seconds 6℃/second max. 6 minutes max. 6℃/second max. 8 minutes max.