14209

Common Mode Inductor
Parameter
Min.
Inductance *
0.6
Typ.
Max.
0.15
Ω
Current
2.0
ARMS
2210
250 VAC
Hipot (Isolation) 2500 VAC
mH
DCR
SRF
Rated Voltage
Units
Insulation Resistance 100MΩ
Temperature Rise 400C Max.
Operating
Temperature Range -400C to +800C
kHz
* Inductance tested at 100mVRMS and 1 kHz
1
Schematic Diagram
(Top View of part)
4
XXXX
L-14209
Physical Dimensions
2
3
4
2
3
inches (mm)
.630
(16.0)
TYP
.709
(18.0)
TYP
1
.846
(21.5)
MAX.
.160
(4.0)
TYP.
.030
(0.7)
TYP.
.394
(10.0)
TYP.
.519
(13.0)
TYP.
2
3
1
4
RHOMBUS P/N: L-14209
CUST P/N:
DATE: 6/22/2001
Rhombus
Industries Inc.
Transformers & Magnetic Products
NAME:
SHEET:
1 OF 1
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
www.rhombus-ind.com