Technical Data

Diaphragm pressure gauge in chemical version NG 100
Application
For gaseous and liquid, also aggressive, low-viscosity media, high overpressure safety, with open lower flange also for high-viscosity media. With fluid filling for measuring points subject to vibrations and high dynamic pressure loads
Ambient temperature
-20°C to +60°C
Media temperature
Max 100°C
Temperature dependent display error
< 0,8% / 10K
Pressure range
Flange ø 100 mm, 0.4 to 25 bar
Flange ø 150 mm, 60 to 250 mbar
Overpressure safety
(with ordering code 0201)
Flange ø 100 mm, 400 mbar, 2.5 x
Flange ø 100 mm, from 0.6 bar, 5 x, max. 40 bar
Flange ø 150 mm, 10 x
Range of application
For static pressure 100% of full scale For dynamic pressure 90% of full scale
Accuracy
Cl. 1,6 according to DIN EN 837-3
Execution
DIN EN 837-3
Movement
Stainless steel
Dial
White, black scale acc. EN 837-3
Pointer
Aluminium, black, DIN EN 837-3
Window
Multilaminated safety glass
Case
Welded, with blow-out lid, back (S1 acc. DIN EN 837-3)
Protection
IP 65 acc. EN 60529 / IEC 529
higher protection class possible as an option (see overleaf)
Selection Chart
Ordering code
DPx 100 / xxx.xxx
System design
Standard
With liquid, glycerine 86%
DPC
DPO
Nominal size
NG 100
100
Case
Stainless steel 1.4301, bright drawn, welded
8
Structural shape
Direct mounting
1
Upper flange
Ø 100 stainless steel 1.4301
Ø 150 stainless steel 1.4301
Special versions
For special versions see page 3
3
6
Notes:
*CoNiCr alloy, durability similar to 1.4571
1) for flange ø 150 with PFA coating
2) only possible without filling
Scale
Standard
1
Measuring element
Duratherm 600* with Viton seal
Duratherm 600* with PTFE coating 1)
(E) 3
(P) 5
Lower flange
Male connection G½, stainless steel 1.4571
For further lower flanges see below
3
9
www.baumer.com
Design and specification subject to change without notice.
Data sheet A 23 D1.311
Page 1
Display range corresponding to upper flange ø
Order ø 150
number mbar
116 2)
126
136
146
156
396 2)
406
416
426
436
686 2)
696 2)
706
716
726
   0 …
   0 …
   0 …
   0 …
   0 …
-   60 …
- 100 …
- 160 …
- 250 …
- 400 …
-   20 …
-   40 …
-   40 …
-   60 …
-   60 …
Measuring Order ø 150
element
number mbar
  60
100
160
250
400
   0
   0
   0
   0
0
  40
  20
  60
  40
100
E
EP
EP
EP
P
E
EP
EP
EP
P
E
E
EP
EP
EP
736
746
756
766
776
- 100 …
- 100 …
- 150 …
- 150 …
- 250 …
  60
150
100
250
150
Measuring
element
Order
number
EP
EP
EP
P
P
015
025
035
045
055
065
075
085
095
305
315
505
515
525
535
545
555
ø 100
bar
   0 …
   0 …
   0 …
   0 …
   0 …
   0 …
   0 …
   0 …
   0 …
-0.6 …
-1.0 …
-1.0 …
-1.0 …
-1.0 …
-1.0 …
-1.0 …
-1.0 …
Measuring Order ø 100
element
numberl mbar
0.6
1.0
1.6
2.5
  4
  6
10
16
25
0.0
0.0
0.6
1.5
3
5
9
15
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
156
436
766
776
786
796
806
816
   0 …
- 400 …
- 150 …
- 250 …
- 200 …
- 400 …
- 400 …
- 600 …
Measuring
element
400
0
250
150
400
200
600
400
E
E
E
E
EP
EP
EP
EP
Dimensions
G1/2
27
Size table
NG
D
a
b
h
F
mm
mm
mm
mm
mm
100
101
16
50
81
100
150
Weight in kg
System design
DPC
DPO
approx. 1.7
approx. 2.0
approx. 3,0
approx. 3,4
Notes: *Dependent on lower flange (value of male lower flange )
www.baumer.com
Design and specification subject to change without notice.
Data sheet A 23 D1.311
Page 2
Lower flanges
Lower flange
ø 100 mm
Ordering code Ordering code with PTFE
ø 150 mm
Ordering code Ordering code with PTFE
Plugs
G1/2
1/
2“-NPT
M 20x1,5
Standard
0024
0013
0302
Standard
0024
0013
0304
PN 10 to
40 bar
DN 15
DN 25
DN 50
0342
0344
0372
0356
0358
0378
0362
0364
PN 300 to 600 lbs
DN 1/2“
DN 1“
DN 2“
0422
0426
0430
0442
0446
0450
0470
DIN 2501
ANSI
Notes: for flange dimensions see chapter A23, data sheet D1.395
Special versions
Components
Ring
Protection
Measuring system
Pointer
Dial
Case filling
for DPO
Miscellaneous
Special design
Ordering code
Remark
Gloss brushed
Air and watertight to IP 67
overpressure safe
Micro-adjustable pointer
Dial inscription: «Pabs» (pointer at 1 bar)
Unscaled, start and end values marked
Red mark at…
Green mark at…
Display same as/similar to catalogue, but different unit of measurement
Display same as/similar to catalogue, but different scaling
Customer logo
Techn. inscription
Dampening liquid glycerine 86%
(-25°C ...100°C)
Dampening liquid glycerine 99,5%
(5°C ...100°C)
Dampening liquid silicone oil AK 100
(-35°C ...100°C)
Dampening liquid paraffin oil
(-10°C ...100°C)
Screws secured with ”Loctite”
0106
0114
0201
0678
0691
0725
9700
9701
9704
9705
9710
9711
0774
0775
0776
0777
0799
www.baumer.com
Design and specification subject to change without notice.
Standard Data sheet A 23 D1.311
Page 3
UK/2009-10-05 This data sheet may only be reproduced in full.
www.baumer.com
Design and specification subject to change without notice.
Data sheet A 23 D1.311
Page 4