ROHM TCM0G1064758R

Chip tantalum capacitors
(Bottom surface electrode type)
TC Series M Case
zFeatures (M)
With an original bottom surface electrode structure.
1) Excellent adhesion.
2) Easy visual recognition of fillets.
3) Large capacitance, low ESR.
zDimensions (Unit : mm)
Anode mark
(Unit : mm)
Dimensions
M case
L
1.6 +
− 0.1
W1
0.85 +
− 0.1
W2
0.55 +
− 0.1
H
0.8 +
− 0.1
S
0.5 +
− 0.1
H
L
+
−
zPart No. Explanation
T C
M
1 A
1
2
3
4
5
4
M
8 R
5
6
4 Nominal capacitance
1 Series name
Nominal capacitance in pF in 3 digits:
2 significant figures followed by the figure
representing the number of 0's.
TC
2 Case style
TC
7
M
5 Capacitance tolerance
3 Rated voltage
Rated voltage (V)
CODE
2.5 4 6.3 10 16
0E 0G 0J 1A 1C
M: +
− 20%
6 Taping
8 : Tape width
R : Positive electrode on the side opposite to sprocket hole
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
1/6
2009.11 - Rev.G
TC Series M Case
Data Sheet
z Rated table
Rated voltage (V)
(µF)
2.5
0E
4
0G
0.47 (474)
6.3
0J
M∗
10
1A
M∗
16
1C
M
M
M
M
20
1D
0.68 (684)
1.0 (105)
1.5 (155)
2.2 (225)
3.3 (335)
4.7 (475)
M
M
M
M
M
M
M
M∗
6.8 (685)
10 (106)
15 (156)
22 (226)
M
33 (336)
M∗
47 (476)
68 (686)
Remark) Case size codes (M) in the above show products line-up.
∗ Under development
z Marking
The indications listed below should be given on the surface of a capacitor.
(1) Polarity
: The polarity should be shown by bar. (on the anode side)
(2) Rated DC voltage : Due to the small size of M case, a voltage code is used as shown below.
(3) Visual typical example
(1) voltage code (2) capacitance code
Rated DC
Voltage (V)
2.5
Capacitance
Code
S
Nominal
Capacitance (µF)
0.47
g
4
W
0.68
j
6.3
A
1.0
A
10
E
1.5
C
16
J
2.2
N
3.3
S
4.7
W
6.8
a
10
e
15
j
22
Voltage
Code
e
[M case]
note 1)
n
33
s
47
A
s
− −
(1) (2)
As
note 2) voltage code and capacitance code are variable with parts number
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
2/6
2009.11 - Rev.G
TC Series M Case
Data Sheet
z Characteristics
Performance
Item
Operating Temperature
−55°C to +125°C
Maximum operating
temperature with no voltage
derating
+85°C
Test conditions (based on JIS C 5101−1 and JIS C 5101−3)
Voltage reduction when temperature exceeds +85°C
Rated voltage (VDC)
2.5 4 6.3 10 16
at 85°C
Category voltage (VDC)
1.6 2.5 4 6.3 10
at 125°C
Surge voltage (VDC)
3.2 5.2 8 13 20
at 85°C
DC Leakage current
Shall be satisfied the voltage on
" Standard list "
As per 4.9 JIS C 5101-1
As per 4.5.1 JIS C 5101-3
Voltage : Rated voltage for 5min
Capacitance tolerance
Shall be satisfied allowance range.
±20%
As per 4.7 JIS C 5101-1
As per 4.5.2 JIS C 5101-3
Measuring frequency : 120±12Hz
Measuring voltage : 0.5Vrms +1.5.DC
Measuring circuit
: DC Equivalent series circuit
Tangent of loss angle
(Df, tan δ)
Shall be satisfied the voltage on
" Standard list "
As per 4.8 JIS C 5101-1
As per 4.5.3 JIS C 5101-3
Measuring frequency : 120±12Hz
Measuring voltage : 0.5Vrms +1.5.DC
: DC Equivalent series circuit
Measuring circuit
Impedance
Shall be satisfied the voltage on
" Standard list "
As per 4.10 JIS C 5101-1
As per 4.5.4 JIS C 5101-3
Measuring frequency : 100±10kHz
Measuring voltage : 0.5Vrms or less
Measuring circuit
: DC Equivalent series circuit
Appearance
There should be no significant abnormality.
The indications should be clear.
L.C.
Less than 200% of initial limit
∆C / C
TCM0J336 : Within ±30% of initial value.
Others : Within ±20% of initial value.
Df (tan δ)
Less than 200% of initial limit
As per 4.14 JIS C 5101-1
As per 4.6 JIS C 5101-3
Dip in the solder bath
Solder temp
: 260±5°C
Duration
: 5±0.5s
Repetition
:1
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Appearance
There should be no significant abnormality.
The indications should be clear.
L.C.
Less than 200% of initial limit
∆C / C
TCM0J336 : Within ±30% of initial value.
Others : Within ±20% of initial value.
Temp.
Time
1
−55 +
− 3°C
30±3min.
Less than 200% of initial limit
2
Room temp.
125 +
− 2°C
3min.or less
Resistance to
Soldering heat
Temperature
cycle
Df (tan δ)
As per 4.16 JIS C 5101-1
As per 4.10 JIS C 5101-3
Repetition : 5 cycles
(1 cycle : steps 1 to 4) without discontinuation.
3
30±3min.
4
Room temp. 3min.or less
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
Moisture
resistance
Appearance
There should be no significant abnormality.
The indications should be clear.
L.C.
Less than 200% of initial limit
∆C / C
TCM0J336 : Within ±30% of initial value.
Others : Within ±20% of initial value.
Df (tan δ)
Less than 200% of initial limit
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
3/6
As per 4.22 JIS C 5101-1
As per 4.12 JIS C 5101-3
After leaving the sample under such atmospheric
condition that the temperature and humidity are
60±2°C and 90 to 95% RH,respectiveiy, for 500±12h
leave it at room
temperature for over 24h and then measure the
sample.
2009.11 - Rev.G
TC Series M Case
Data Sheet
Performance
Item
Temperature
Stability
Temp.
−55°C
∆C / C
TCM0G336 : Within 0/−30% of initial value
TCM0J226 : Within ±15/−5% of initial value
TCM0J336 : Within ±15/−5% of initial value
Others : Within 0/−15% of initial value
Df (tan δ)
Shall be satisfied the voltage on " Standard list "
Temp.
+85°C
∆C / C
TCM0G336 : Within +15/-5% of initial value
TCM0J226 : Within ±15/−5% of initial value
TCM0J336 : Within ±15/−5% of initial value
Others : Within +15/0% of initial value
Df (tan δ)
Shall be satisfied the voltage on " Standard list "
L.C.
Less than 1000% of initial value
Temp.
+125°C
∆C / C
TCM0G336 : Within +20/-5% of initial value
Others : Within +20/0% of initial value
Df (tan δ)
Shall be satisfied the voltage on " Standard list "
L.C.
Less than 1000% of initial value
Appearance
There should be no significant abnormality.
L.C.
Less than 200% of initial limit
∆C / C
Within ±20% of initial value
Df (tan δ)
Less than 200% of initial limit
Loading at
Appearance
High temperature
L.C.
Terminal
strength
As per 4.29 JIS C 5101-1
As per 4.13 JIS C 5101-3
−
L.C.
Surge voltage
Test conditions (based on JIS C 5101−1 and JIS C 5101− 3)
There should be no significant abnormality.
Less than 200% of initial limit
∆C / C
TCM0G336 : Within ±30% of initial value
TCM0J226 : Within ±30% of initial value
TCM0J336 : Within ±30% of initial value
Others : Within ±20% of initial value
Df (tan δ)
Less than 200% of initial limit
Capacitance
The measured value should be stable.
Appearance
There should be no significant abnormality.
As per 4.26JIS C 5101-1
As per 4.14JIS C 5101-3
Apply the specified surge voltage every 5±0.5 min.
for 30±5 s. each time in the atmospheric condition of 85±2°C.
Repeat this procedure 1,000 times.
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
As per 4.23 JIS C 5101-1
As per 4.15 JIS C 5101-3
After applying the rated voltage for 1000+36/0 h without
discontinuation via the serial resistance of 3Ω or less
at a temperature of 85±2°C, leave the sample at room
temperature / humidity for over 24h and measure the value.
As per 4.35 JIS C 5101-1
As per 4.9 JIS C 5101-3
A force is applied to the terminal until it bends to 1mm and
by a prescribed tool maintain the condition for 5s.
(See the figure below)
(Unit : mm)
50
20
F (Apply force)
R230
1
thickness=1.6mm
45
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
4/6
45
2009.11 - Rev.G
TC Series M Case
Data Sheet
Performance
Item
Adhesiveness
Test conditions (JIS C 5101−1 and JIS C 5101− 3)
As per 4.34 JIS C 5101-1
As per 4.8 JIS C 5101-3
Apply force of 5N in the two directions shown in the figure
below for 10±1s after mounting the terminal on a circuit board.
The terminal should not come off.
product
YAA
C105
Apply force
a circuit board
Dimensions
Refer to "External dimensions"
Measure using a caliper of JIS B 7507 Class 2
or higher grade.
Resistance to solvents
The indication should be clear
As per 4.32 JIS C 5101-1
As per 4.18 JIS C 5101-3
Dip in the isopropyl alcohol for 30±5s, at room
temperature.
Solderability
3/4 or more surface area of the solder coated
terminal dipped in the soldering bath should
be covered with the new solder.
As per 4.15.2 JIS C 5101-1
As per 4.7 JIS C 5101-3
Dip speed=25±2.5mm / s
Pre−treatment(accelerated aging): Leave
the sample on the boiling distilled water for 1 h.
Solder temp. : 245±5°C
Duration
: 3±0.5s
Solder
: M705
Flux
: Rosin 25% IPA 75%
Vibration
Capacitance Measure value should not fluctuate during the
measurement.
Appearance There should be no significant abnormality.
As per 4.17 JIS C 5101-1
Frequency : 10 to 55 to 10Hz/min.
Amplitude : 1.5mm
Time : 2h each in X and Y directions
Mounting : The terminal is soldered on a print circuit board.
z Standard products list, TC series M case
Df
Impedance
Leakage
120Hz
100kHz
current
(%)
Tolerance
25°C
(%)
1WV.300s
25°C
125°C
(Ω)
−55°C
(µA)
85°C
Rated
voltage
85°C
Category
voltage
125°C
Surge
voltage
85°C
(V)
(V)
(V)
TC M 0G 475
4
2.5
5.2
4.7
+
− 20
0.5
30
20
30
9.0
TC M 0G 106
4
2.5
5.2
10
+
− 20
0.5
30
20
30
9.0
Part No.
Cap.
120Hz
(µF)
TC M 0G 226
4
2.5
5.2
22
+
− 20
0.9
30
20
30
9.0
TC M 0G 336
4
2.5
5.2
33
+ 20
13.0
60
30
40
9.0
TC M 0J 475
6.3
4
8
4.7
+
− 20
0.5
30
20
30
9.0
TC M 0J 106
6.3
4
8
10
+
− 20
0.6
30
20
30
9.0
TC M 0J 226
6.3
4
8
22
+
− 20
13.0
60
30
40
9.0
TC M 1A 105
10
6.3
13
1.0
+
− 20
0.5
15
10
15
15.0
TC M 1A 225
10
6.3
13
2.2
+
− 20
0.5
30
20
30
13.5
TC M 1A 475
10
6.3
13
4.7
+
− 20
0.5
30
20
30
9.0
TC M 1A 106
10
6.3
13
10
+
− 20
10.0
30
20
30
9.0
0.5
15
10
15
15.0
0.5
30
20
30
13.5
TC M 1C 105
16
10
20
1.0
+
− 20
TC M 1C 225
16
10
20
2.2
+
− 20
+ 20% )
=Tolerance (M : −
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
5/6
2009.11 - Rev.G
TC Series M Case
Data Sheet
z Packaging specifications
A+
−0.1 t1 +
− 0.1
−0.1 W+
− 0.2 E+
−0.1 F +
−0.05 P1+
− 0.05 P0+
− 0.05 t2 +
−0.1 P2 +
−0.1 B+
Case code
1.0
M
1.8
8.0
1.75
3.5
4.0
2.0
4.0
0.20
1.0
Taping [M case]
t1
φ1.5
+0.1
0
E
A
F
W
B
t2
P1
P2
P0
Feeding direction
z Packaging style
Case code
Packaging
M case
Taping
Packaging style
plastic taping
Symbol Basic ordering units
φ180mm Reel
R
4,000pcs
φ60 +1
0
0
φ180−1.5
11.4+
−1.0
φ13+
−0.2
+1.0
9.0 0
Reel [M case]
Pull direction
Label sticking position
EIAJ ET−7200B compatible
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
6/6
2009.11 - Rev.G
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller,
fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of
any of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2009 ROHM Co., Ltd. All rights reserved.
R0039A