ROHM TCOB1A476M8R

Chip tantalum capacitors
TCO Series B Case
zFeatures (B)
1) Conductive polymer used for the
cathode material.
2) Ultra-low ESR.
(1/10 compared with the conventional type)
3) Screening by thermal shock.
zDimensions (Unit : mm)
Anode mark
(Unit : mm)
W1
L
Dimensions
B case
H
W2
S
S
+
−
L
3.5 +
− 0.2
W1
2.8 +
− 0.2
W2
1.9 +
− 0.2
H
1.9 +
− 0.2
S
0.8 +
− 0.3
zPart No. Explanation
Nominal capacitance in pF in
3 digits: 2 significant figures
followed by the figure
representing the number of 0's.
Series name
Case style
T C O
B
Nominal capacitance
0
J
4
7
6
M
8 R
Capacitance tolerance
Rated voltage
Code
Rated voltage (V)
0E
2.5
0G
4
0J
6.3
1A
10
Code Capacitance tolerance
+− 20%
M
8 : Tape width
R : Positive electrode
on the side opposite
to sprocket hole
zRated Table
Rated voltage (V.DC)
µF
2.5
0E
4
0G
6.3
0J
10
1A
j
22
n
33
B
B
B
∗B
B
s
47
w
68
a
100
e
150
j
220
∗B
330
∗B
n
B
B
∗B
∗B
∗ Under development
indicates new product
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
1/5
2009.01 - Rev.E
Data Sheet
TCO Series B Case
zMarking
The indications listed below should be given on the surface of a capacitor.
(1) Polarity
: The polarity should be shown by bar. (on the anode side)
(2) Rated DC voltage : Due to the small size of B case, a voltage code is used as shown below.
(3) Visual typical example
(1) voltage code (2) capacitance code
Rated DC
Voltage (V)
2.5
Capacitance
Code
a
Nominal
Capacitance (µF)
10
g
4
e
15
j
6.3
j
22
A
10
n
33
s
47
Voltage
Code
e
[B case]
note 1)
w
68
a
100
e
150
j
220
n
330
j
s
− −
(1) (2)
js
manufacture code
note 2) voltage code and capacitance code are variable with parts number
zCharacteristics
Item
Operating Temperature
Test conditions
(based on JIS C 5101−1 and JIS C 5101−3)
Performance
−55 C to +105 C
Voltage reduction when temperature exceeds+85 C
Maximum operating
+85 C
temperature with no voltage
derating
Rated voltage
(VDC)
2.5 4 6.3 10
Category voltage
(VDC)
Surge voltage
(VDC)
2 3.2 5
at 85 C
8
at 105 C
3.2 5.2 8 13
at 85 C
DC Leakage current
3µA or 0.1CV whichever is greater
Shown in " Standard list "
Rated voltage for 5min
Capacitance tolerance
+
−20% Shall be satisfied allowance range.
Tangent of loss angle
(Df, tan δ)
Measuring frequency : 120+
−12Hz
Measuring voltage : 0.5Vrms
+1.5 to 2V.DC
Measuring circuit
: DC Equivalent series circuit
Shall be satisfied the voltage on " Standard list " Measuring frequency : 120 +
−12Hz
Measuring voltage : 0.5Vrms
+1.5 to 2V.DC
Measuring circuit
: DC Equivalent series circuit
Shall be satisfied the voltage on " Standard list " Measuring frequency : 100 +
−10kHz
Measuring voltage : 0.5Vrms or less
ESR
Resistance to Appearance There should be no significant abnormality.
The indications should be clear.
Soldering heat
∆C / C
Less than 150% of initial limit
Within +
− 20% of initial value
tan δ
Less than 150% of initial limit
L.C.
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
Dip in the solder bath
+5 C
Solder temp
: 240−
Duration
: 10+
−0.5s
:1
Repetition
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
2/5
2009.01 - Rev.E
Data Sheet
TCO Series B Case
Item
Temperature
cycle
Moisture
resistance
Temperature
Stebility
Appearance There should be no significant abnormality.
L.C
Less than 500% of initial limit
∆C / C
Within+
−20% of intial value
Df
(tan δ)
Less than 150% of initial limit
Temp.
−55+
1
−3 C
2 Room temp.
+2 C
105−
3
4 Room temp.
Appearance There should be no significant abnormality.
The indications should be
L.C
Less than 150% of initial limit
∆C / C
+30% / −20%
Df
(tan δ)
Less than 150% of initial limit
Temp.
−55 C
∆C / C
Within 0/−20% of initial value
Df
(tan δ)
Shall be satisfied the voltage on " Standard list "
Temp.
+105 C
Within +50/0% of initial value
Df
(tan δ)
Shall be satisfied the voltage on " Standard list "
L.C
Less than 1CV
Appearance There should be no significant abnormality.
∆C / C
Df
(tan δ)
Time
+3min
30−
3min.or less
30+
−3min
3min.or less
After leaving the sample under such atmospheric
condition that the temperature and humidity are
+ 2 C and 90 to 95% RH,respectiveiy,for 500 −
+24h
40 −
leave it at room
temperature for over 24h and then measure the
sample.
−
∆C / C
L.C
Repetition : 5 cycles
(1 cycle : steps 1 to 4) without discontinuation.
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
L.C
Surge
voltage
Test conditions
(based on JIS C 5101−1 and JIS C 5101−3)
Performance
Less than initial limit
Within +
− 20% of initial value
Less than initial limit
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
3/5
Apply the specified serge voltage every 5+
− 0.5 min.
for 30+
−5 s. each time in the atmospheric condition
of 85+
−2 C.
Repeat this rocedure 1,000 times.
After the specimens, leave it at room temperature for
over 24h and then measure the sample.
2009.01 - Rev.E
Data Sheet
TCO Series B Case
Item
Test conditions
(based on JIS C 5101−1 and JIS C 5101−3)
Performance
After applying the rated voltage for 1000+72 h
without discontinuation via the serial resistance
of 3Ω or less at a temperature of 85+
− 2 C, leave
the sample at room temperature / humidity for
over 24h and measure the value.
Loading at
Appearance There should be nonsignificant
High temperature
abnormality.
L.C
Less than 200% of initial limit
∆C / C
Within +
− 20% of initial value
Df
(tan δ)
150% of initial limit less than
Terminal strength Capacitance The measured value should be stable.
Appearance There should nonsignificant abnormality.
A force is applied to the terminal until it bends
to 1mm and by a perscribed tool maintain the
condition for5s.(See the figure below)
20
50
(Unit : mm)
F (Apply force)
R230
1mm
thickness=1.6mm
45
Adhesiveness
The terminal should not come off.
45
Apply force of 5N in the two directions shown
+ 1s after mounting the
in the figure below for 10 −
terminal on a circuit board.
product
YAA
C105
Apply force
a circuit board
Dimensions
Refer to "External dimensions"
Measure using a caliper of JISB 7507 Class 2
or higher grade.
Resistance to solvents
The indication should be clear
Solderability
3/4 or more surface area of the solder coated
terminal dipped in the soldering bath should
be covered with the new solder.
+5s, at room
Dip in the isopropyl alcohol for 30−
temperature.
Dip speed=25 +
− 2.5mm / s
Pre−treatment(accelerated aging): Leave
the sample on the boiling distilled water for 1 h.
Solder temp.
. : 245 +
−5 C
: 3+
Duration
− 0.5s
: M705
Solder
: Rosin25%
Flux
IPA75%
Frequency : 10 to 55 to 10Hz/min.
Amplitude : 1.5mm
Time : 2h each in X and Y directions
Mounting : The terminal is soldered on a print
circuit board.
Vibration
Capacitance Measure value should not fluctuate during the
measurement.
Appearance There should no significant abnormality.
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
4/5
2009.01 - Rev.E
Data Sheet
TCO Series B Case
zStandard list, TCO series
< B case : 3528 size >
Part No.
TCO
TCO
TCO
TCO
TCO
TCO
Rated
Voltage
85°C
Category
Voltage
105°C
Surge
Voltage
85°C
Cap.
120Hz
(V)
(V)
(V)
(µF)
4
6.3
6.3
6.3
10
10
3.2
5
5
5
8
8
5
8
8
8
13
13
150
33
47
100
33
47
B 0G 157 M
B 0J 336 M
B 0J 476 M
B 0J 107 M
B 1A 336 M
B 1A 476 M
Df
ESR
Tolerance Leakage
120Hz
100kHz
Current
(%)
25°C
1WV 5min
25°C
105°C (mΩ)
−55°C
(µA)
(%)
85°C
+
− 20
+
− 20
+
− 20
+
− 20
+ 20
−
+
− 20
60
21
30
63
33
47
8
8
8
8
8
8
8
8
8
8
8
8
12
12
12
12
12
12
150
150
150
150
150
150
zPackaging specifications
Reek [ B case ]
Chip
4.0±0.1
t2
2.0±0.05
Pull-out direction
0
φ180 −1.5
4.0±0.1
11.4+
−1.0
φ60 +1
0
B
+1.0
9.0 0
3.5±0.05
A
t1
φ13+
−0.2
+0.1
−0
8.0±0.2
φ1.5
1.75±0.1
Tape [ B case ]
Unit : [mm]
Case
A+
−0.1
B+
−0.1
B
3.3
3.8
t1 +
− 0.05
0.25
Pull direction
Labelsticling position
t2 +
−0.1
2.2
EIAJ ET−7200B compatible
zPackaging style
Case code
package
B
Taping
Packaging style
plastic taping
Symbol Basic ordering units
φ180mmReel
R
2,000pcs
zDamp proof package
One reel is packed in aluminum bag.
The size of aluminum bag is 240(a) x 250(b)mm.
The size up to 230(c)mm is to zipper.
A desiccant is packed with a reel.
The aluminum bag is heat-sealed.
The label of the same as the label on the reel is placed on the
aluminum bag.
b
C
a
www.rohm.com
c 2009 ROHM Co., Ltd. All rights reserved.
○
5/5
2009.01 - Rev.E
Appendix
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM
CO.,LTD.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you
wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM
upon request.
Examples of application circuits, circuit constants and any other information contained herein illustrate the
standard usage and operations of the Products. The peripheral conditions must be taken into account
when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document. However, should
you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and examples
of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to
use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information.
The Products specified in this document are intended to be used with general-use electronic equipment
or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or
malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard against the
possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as
derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your
use of any Product outside of the prescribed scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or system
which requires an extremely high level of reliability the failure or malfunction of which may result in a direct
threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment,
aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear
no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may be controlled under
the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact your nearest sales office.
ROHM Customer Support System
www.rohm.com
Copyright © 2009 ROHM Co.,Ltd.
THE AMERICAS / EUROPE / ASIA / JAPAN
Contact us : webmaster @ rohm.co. jp
21 Saiin Mizosaki-cho, Ukyo-ku, Kyoto 615-8585, Japan
TEL : +81-75-311-2121
FAX : +81-75-315-0172
Appendix-Rev4.0