CS5480/84/90 Product Bulletin

Four Channel Energy Measurement IC
CS5484/80/90
Market Applications
Utility Meters
VDDA
VDDD
RESET
IIN1+
4th Order
PGA
SSEL
HPF
Option
Digital Filter
ΔΣ Modulator
IIN1-
CS
Power Supply Monitoring
Smart Appliances
UART/SPI
Serial
Interface
IIN2+
4th Order
ΔΣ Modulator
PGA
IIN2-
HPF
Option
Digital Filter
RX/SDI
TX/SDO
SCLK
Home Energy Management
VIN1+
4th Order
10x
Emerging Smart Home and Smart Grid
Applications
HPF
Option
Digital Filter
ΔΣ Modulator
VIN1-
DO1
Calculation
Configurable
Digital
Outputs
VIN2+
10x
VIN2-
M
U
X
4th Order
ΔΣ Modulator
Temperature
Sensor
HPF
Option
Digital Filter
System
Clock
Voltage
Reference
Clock Generator
XIN XOUT
CPUCLK
DO3
DO4
MODE
GNDA
DO2
VREF+
VREF-
GNDD
For manufacturers of utility meters, appliances and smart home energy solutions, Cirrus Logic’s
CS5484/80/90 family of analog front end (AFE) energy measurement ICs provide the industry’s
highest measurement accuracy and lowest cost, with the flexibility and ease of use to react quickly to
rapidly changing market conditions.
The CS548/9X family, when combined with an MCU of your choice, offers a clear alternative to
system-on-a-chip solutions, whose “one size fits all” approach limits the designers ability to optimize
the design for performance and cost requirements.
With an energy measurement accuracy of 0.1% over 4,000:1 dynamic range, the CS548/9X family
offers superior measurement performance with no user programming required, and ultra-fast calibration.
Its multiple interface options, including UART, SPI and four digital outputs, provide flexibility to quickly
react to changing market requirements. Plus, each digital output is individually configurable to provide
energy pulses, zero crossing, energy direction or interrupt functions on any of the provided pins.
Features:
Cirrus Logic, Inc.
2901 Via Fortuna
Austin, Texas 78746
United States
T +1-512-851-4000
F +1-512-851-4977
Toll-Free +1-800-888-5016
Sales Support
North America +1 800-625-4084
Asia Pacific +852 2376-0801
Japan +81 (3) 5226-7757
Europe/UK +44 (90) 1628-891-300
www.cirrus.com
AASuperior analog performance with ultra low
noise level and high SNR
AA Energy measurement accuracy of 0.1% over
4000:1 dynamic range
AA Current RMS measurement accuracy of 0.1%
over 1000:1 dynamic range
AA 2, 3 or 4 independent 24-bit, 4th-order Delta
Sigma modulators for voltage and current
measurement
AA Configurable digital outputs for energy pulses,
zero crossing or energy direction
AA Supports shunt resistor, CT and Rogowski coil
current sensors
AA On-chip measurements / calculations:
AA Active, reactive and apparent power
AA RMS voltage and current
AA Power factor and line frequency
AA Instantaneous voltage, current and power
AA Overcurrent, voltage sag and voltage
swell detection
AA UART / SPI serial interface options
AA Internal register protection via checksum and
write-protection
AA On-chip voltage reference (25 ppm/°C typ.)
AA Single 3.3V power supply
AA Low power consumption: <13mW
AA Small, low cost package options
Electrical Specifications
Active Energy Accuracy
Reactive Energy Accuracy
0
-0.5
-1
Percent Error (%)
Lagging PF = 0.5
Leading PF = 0.5
PF=1
0.5
IRMS Accuracy
1
1
Percent Error (%)
Percent Error (%)
1
0.5
0
-0.5
0.5
0
-0.5
-1
-1
05
00 1000 1500 2000 2500 3000 3500 4000 4500
lRMS Error
05
Current Dynamic Range (x:1)
00 1000 1500 2000 2500 3000 3500 4000 4500
05
00
1000
1500
Current Dynamic Range (x:1)
AFE + MCU Advantage vs Using SOCs
AA Pre-programmed industry standard power calculations saves
money and accelerates production schedules and time to market
AA Up to 10X faster calibration
AA Pair Cirrus Logic AFE with cost-optimized microcontroller tailored to
the demands of the application
AA Lock in AFE for metrology and easily change MCU to quickly adapt
to changing market requirements
AA Never pay for more memory, IO or performance than required
Demonstration Board
The CDB5484/80/90U is an extensive tool designed to evaluate the
functionality and performance of the Cirrus Logic CS5484/80/90 family.
Shunt resistors, current transformers or Rogowski coils can be connected
to the analog inputs. Intuitive GUI software provides easy and full access
to the on-board CS5484/80/90 device and MCU. On-board LEDs and
LCD displays enable stand alone operation for extended testing. Getting
started with a CDB enables fast and easy preliminary evaluation of Cirrus
Logic’s AFE products.
Part
CS5484
CS5480
CS5490
CS5467
CS5464
CS5463
CS5451A
ADC Converters
4
3
2
4
3
2
6
Current Sensor Options Shunt/CT/Rogowski Shunt/CT/Rogowski Shunt/CT/Rogowski Shunt/CT
Shunt/CT
Shunt/CT
Shunt/CT
Active Energy
Accuracy
0.1% over 4000:1
dynamic range
0.1% over 4000:1
dynamic range
0.1% over 4000:1
dynamic range
0.1% over 1000:1
dynamic range
0.1% over 1000:1
dynamic range
0.1% over 1000:1
dynamic range
N/A
Reactive Energy
Accuracy
0.1% over 4000:1
dynamic range
0.1% over 4000:1
dynamic range
0.1% over 4000:1
dynamic range
0.2% over 1000:1 0.2% over 1000:1 0.2% over 1000:1 N/A
dynamic range
dynamic range
dynamic range
IRMS Accuracy
0.1% over 1000:1
dynamic range
0.1% over 1000:1
dynamic range
0.1% over 1000:1
dynamic range
0.1% over 1000:1
dynamic range
0.1% over 1000:1
dynamic range
0.2% over 1000:1 N/A
dynamic range
SNR
80dB
80dB
80dB
78dB
78dB
78dB
77dB
Serial Communication
SPI/ UART
SPI/ UART
UART
SPI
SPI
SPI
SPI
Digital Outputs
4x Configurable
Outputs
3x Configurable
Outputs
Single Configurable Energy Pulses
Output
Energy Pulses
Energy Pulses
—
VREF Drift
25ppm/C
25ppm/C
25ppm/C
40ppm/C
40ppm/C
40ppm/C
25ppm/C
Input Voltage
3.3V
3.3V
3.3V
5V Analog
3.3/5V Digital
5V Analog
3.3/5V Digital
5V Analog
3.3/5V Digital
3V Analog
3V Digital
Power Consumption
<13mW
<13mW
<13mW
25mW
25mW
21mW
23mW
Package
28 QFN
24 QFN
16 SOIC
28 SSOP
28 SSOP
24 SSOP
28 SSOP