D1U4CS-D-2100-5x-HA3DC www.murata-ps.com DC-DC Front End Power Supply PRODUCT OVERVIEW This highly efficient, 2100W, 54V (or 52.5V) output DC-DC converter is designed to deliver reliable bulk power to 54V distributed power systems, making it ideal for telecom and other high power density applications. The power supplies are N+1 redundant, hot-swappable, and have internal cooling fans. The power supply automatically recovers from overcurrent and overtemperature faults, and status information is provided through front panel LEDs, logic signals and its PMBus™ / I2C interface. ORDERING GUIDE Output Part Number FEATURES 2100W output power 93% efficient at half power Floating 54V main output and 5V standby output 1U height: 4"x13.5"x1.6" 24.3 Watts per cubic inch density N+1 redundancy capable, including hot-swapping Droop current sharing Overvoltage, overcurrent, overtemperature protection Internal cooling fans D1U4CS-D-2100-54-HA3DC D1U4CS-D-2100-52-HA3DC Standby Aux Power Main Output 2100W 2040W 54V 52.5V 5V 5V Output Current Share Front to back Front to back Droop Droop INPUT CHARACTERISTICS Parameter Conditions Input Voltage Operating Range Turn-on Input Voltage Turn-off Input Voltage Maximum Current at Vin = -40V DC Line Inrush Peak Current Min. Input Power and Output Power 20% load 50% load 100% load I2C reading accuracy Efficiency (40Vdc - 72Vdc) Nom. -40 -43 -38.5 Ramp up Ramp down 2100W PMBus™ / I²C interface with status indicators RoHS compliant Airflow Max. -72 -44 -39.5 59 90 5 4 2.5 25% load 50% load 100% load 90 93 91 Units Vdc A Apk % OUTPUT VOLTAGE CHARACTERISTICS Output Voltage 54V model 52.5V model Main output, all models Parameter Conditions Min. Typ. Max. Voltage Set Point Accuracy Line & Load Regulation Voltage Set Point Accuracy Line & Load Regulation Droop Ripple Voltage & Noise1 Output Current Load Capacitance 50% load 53.87 51.98 52.36 50.49 54 54.14 56.06 52.63 54.54 50% load 52.5 0.075 20MHz Bandwidth 0 0 500 40 6800 Units Vdc Vdc V/Amp mVp-p A uF Voltage Set Point Accuracy 50% load 4.95 5 5.05 Vdc Line & Load Regulation 4.808 5.196 2 Droop 0.25 V/Amp 5Vaux Ripple Voltage & Noise1 20MHz Bandwidth 50 mVp-p Output Current 0.75 A 1 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF electrolytic capacitance on each of the power supply outputs. 2 5Vaux is referenced to logic ground. For full details go to www.murata-ps.com/rohs CB Test Certificate and Test Report www.murata-ps.com/support CPS_D1U4CS-D-2100-5x-HA3DC.A04 Page 1 of 5 D1U4CS-D-2100-5x-HA3DC DC-DC Front End Power Supply OUTPUT CHARACTERISTICS Parameter Conditions Output Rise Monotonicity Monotonic with no overshoot DC input applied PS_On activated Main Output Ramp, 1A/μs 50% load step 5Vaux Ramp, 1A/μs 50% load step Startup Time Transient Response Current sharing accuracy (up to 8 in parallel) At 100% load Holdup Time 50% load Min. Typ. Max. Units 1 150 3 300 2000 ±200 s ms ±10 8 mV % ms ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Altitude (without derating at 40°C) Altitude (without derating at 55°C) Shock Sinusoidal Vibration MTBF Conditions Min. Non-condensing Non-condensing -40 -5 5 5 4000 1800 IEC 60068-2-27 IEC 60068-2-64 Telcordia SR-332 M1C1 @40°C Demonstrated 90% confidence Typ. Max. 85 55 90 95 Units °C % m 439K 60 Hours Hours dB LpAm 300K Acoustic Safety Approvals IEC60950-1:2006/A11:2009 UL60950-1 2nd Ed. 2007-03-27, CSA22.2 N0.60950-1 2nd Ed. 2007.03, EN60690-1:2006+A11:2009 (Evaluated) CE Marking per LVD Input Fuse Power Supply has internal 80A/170VDC slow blow fuse on 48V input Switching Frequency 160KHz for Main Output Converter 200KHz for Standby Output Converter Weight 4.1lbs (1.86kg) PROTECTION CHARACTERISTICS Output Voltage Main Output 5Vaux Parameter Conditions Min. Typ. Max. Units Overtemperature (intake) (54V model only) Overvoltage Overcurrent Overvoltage Overcurrent Autorestart Latching Autorestart Latching Autorestart 57 57 44 60 63 60 48 6.5 1.65 °C V A V A Max. Units 6.0 0.82 ISOLATION CHARACTERISTICS Parameter Insulation Safety Rating / Test Voltage Isolation Conditions Input to Output Input to Chassis - Basic Floating outputs to Chassis Min. 1414 1414 707 Typ. Vdc Vdc Vdc www.murata-ps.com/support CPS_D1U4CS-D-2100-5x-HA3DC.A04 Page 2 of 5 D1U4CS-D-2100-5x-HA3DC DC-DC Front End Power Supply STATUS INDICATOR AND CONTROL SIGNALS Status Conditions Description Input OK LED Green Blinking at 1Hz Off Green Blinking at 1Hz Red Off DC input present and within range DC input present and outside range DC input not present Outputs are present and within regulation Power limit or overcurrent condition Fault condition present No fault condition detected Status Conditions Description Fan monitoring is available through the I2C interface Both fans running normally One fan failed (or rotor locked) Both fans failed (or rotors locked) PMBus CMD E5 Byte 2 bit 3 PMBus CMD E5 Byte 2 bit 3 PMBus CMD E5 Byte 2 bit 3 Output OK LED Fault LED See also ACAN36 for additional LED operation details. FAN MONITORING EMISSIONS AND IMMUNITY Characteristic Standard Compliance Conducted Emissions Radiated Emissions FCC 47 CFR Part 15/CISPR 22/EN55022 FCC 47 CFR Part 15/CISPR 22/EN55022 ESD Immunity IEC/EN 61000-4-2 Radiated Field Immunity Electrical Fast Transients/Burst Immunity Surge Immunity RF Conducted Immunity Magnetic Field Immunity Ring Wave IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 IEC/EN 61000-4-12 Class A, 6dB margin Class A, 6dB margin 8kV contact discharge 15kV operational air discharge 10 V/m, Performance Criteria A 2kV, Performance Criteria A 1kV/1kV, Performance Criteria A 10Vrms, 80% AM, 1kHz, Performance Criteria A 30 A/m 1kV, Performance Criteria A www.murata-ps.com/support CPS_D1U4CS-D-2100-5x-HA3DC.A04 Page 3 of 5 D1U4CS-D-2100-5x-HA3DC DC-DC Front End Power Supply OUTPUT CONNECTOR AND SIGNAL SPECIFICATION DC and Signal Connector: P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 1 2 3 4 -Interrupt #0 Address 2 Logic GND -I2C Reset 5 6 SCL_1 SCL_0 D Vin Vin Vin Vin Vin Vin FRAME Vout Vout Vout Vout Reserved -Interrupt #1 Address 1 Reserved Logic GND Logic GND C -48V -48V -48V -48V Rtn -48V Rtn -48V Rtn GND 54V3 54V3 54V Rtn3 54V Rtn3 Reserved -Output Enable Address 0 -PS Present SDA_1 SDA_0 B Reserved -PS Fault +5Vaux Logic GND Logic GND Logic GND A Note: Connector is viewed from the rear of the PSM Last-to-make, first-to-break shortest pin First to make, last to break longest pin must be implemented in mating connector DC Input: 72Vdc max. DC Output: 54V or 52.5V Pin Assignment Signal Name High Level Low Level Description P1,P2, P3 P4, P5, P6 P7 P8, P9 P10, P11 A3 A2 B4 Frame GND 54V3 54VDC_RTN3 +5V-AUX PS_Fault PS_Present -48VDC Input (-) -48VDC_RTN Input (+) Frame ground Main Output Voltage (+) Main Output Voltage Return (-) Auxiliary Output Output Voltage within specification4 B4 is tied to logic ground inside the power supply B2 OUT_ENABLE_L Enable Main Output (internal 10K pull-up to +5Vdc)5 B6, B5 D6, D5 D1 B3 C3 D3 A1, B1, C1, C4 A4, A5, A6, C5, C6, D4 I2C-SDA_0, I2C-SDA_1 I2C-SCL_0, I2C-SCL_1 I2C Reset ADD0 ADD1 ADD2 Reserved Logic Gnd I2C serial data bus I2C serial clock bus I2C reset Address Input 0, internal Pull-up to Vdd (+5Vdc) Address Input 1, internal Pull-up to Vdd (+5Vdc) Address Input 2, internal Pull-up to Vdd (+5Vdc) Reserved Connected to Logic Gnd >2.4V, OK 0V >3.4V, disabled <1.2V, enabled +5Vdc +5Vdc Comments -50mA, open drain Min 0.6V hysteresis >2.1V, <0.8V >2.1V, <0.8V >2.1V, <0.8V 3 Output voltage setpoint is 52.5V on the D1U4CS-D-2100-52-HA3DC model See also ACAN36 for additional details on fault conditions. PS_Fault remains high when OUT_ENABLE_L is disabled and output is off. 5 Pull OUT_ENABLE_L (pin B2) to Logic Gnd (pin A4, A5, A6, C5, C6, D4) to enable main output. Do not exceed 5.5V on OUT_ENABLE_L pin. 4 D1U MATING CONNECTORS Mating Connector Power Supply Tyco FCI 6450842-2 10106263-B006001LF Straight TBD TBD Right Angle 6450882-2 10106265-B006002C www.murata-ps.com/support CPS_D1U4CS-D-2100-5x-HA3DC.A04 Page 4 of 5 D1U4CS-D-2100-5x-HA3DC DC-DC Front End Power Supply 26.67 ±0.25 0 MECHANICAL DIMENSIONS 3.00 ±0.10 0 6.30 ±0.25 2.44 329.01 ±0.52 4.00 0 4.93 ±0.35 0 23.62 101.60 ±0.50 51.64 ±0.35 0 2X 1.52 86.11 10.92 40.64 ±0.40 23.95 ±0.35 13.49 ±0.25 20.96 ±0.25 0 0 5.46 ±0.25 344.47 ±0.50 26.67 ±0.25 0 3.00 ±0.10 Airflow Front to Back 0 0 50.80 ±0.35 27.71 ±0.35 Dimensions: 4.00" x 13.56"x 1.61" [101.6mm x 344.47mm x 40.64mm] OPTIONAL ACCESSORIES Description Part Number 54V D1U-54D output connector card D1U4CS-54D-CONC APPLICATION NOTES Document Number Description Link ACAN-35 D1U4CS-54D Output Connector Card www.murata-ps.com/data/apnotes/acan-35.pdf ACAN-36 D1U4CS-D-2100-xx-HA3xC Communication Protocol www.murata-ps.com/data/apnotes/acan-36.pdf ACAN-37 D1U4CS-x EEPROM Specification www.murata-ps.com/data/apnotes/acan-37.pdf Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2012 Murata Power Solutions, Inc. www.murata-ps.com/support CPS_D1U4CS-D-2100-5x-HA3DC.A04 Page 5 of 5