D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter PRODUCT OVERVIEW The D2U5T-H3-5000-380-HU3C is a High Efficiency 3500/5000 watt, power factor corrected three phase power supply for 230/480Vac lines with a 380V high voltage (HVDC) main output and a selectable 5V or 3.3V (20W) standby. The unit is provided with Droop Sharing and up to three (3) power modules may be operated in parallel. The power module is hot pluggable. The module is able to protect and recover from over temperature faults, and has status LEDs on the front panel and additional logic and PMBus status signals. Their 2U package and >16.5W/cubic inch power density make them ideal for delivering reliable, efficient power to servers, workstations, storage systems and other 380V HVDC distributed power systems. An optional power shelf is also available that accommodates up to three (3) power modules. ORDERING GUIDE FEATURES 5KW (480Vac), 3.5KW (230Vac) Output Power Very High Efficiency; 95.4% @ 50% FL 380V High Voltage Main Output 3.3V or 5V Standby Output Nominal Dim’s: 5.1"(W) x 18"(L) x 3.3" (2U 16.5 watts/cubic inch power density N+1 redundant (including hot docking) Droop sharing on Main Output Over-voltage, over-current, overtemperature protections Internal cooling fan I2C Bus Interface with status indicators Optional 19" power shelf RoHS compliant Two-year warranty Model Number Power Main Output D2U5T-H3-5000-380-HU3C 5000W 380V INPUT CHARACTERISTICS Parameter Input Frequency Input Voltage Operating Range Turn-on Voltage (Ramp-up) Turn-off Voltage (Ramp-down) Maximum Input Current Inrush Current Power Factor, Range 1, 60Hz Power Factor, Range 2, 60Hz www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Available now at: www.murata-ps.com/en/3d/acdc.html For full details go to www.murata-ps.com/rohs Standby Output 3.3V or 5V (Selectable) Conditions Range 1 Range 2 Range 1 Range 2 Range 1 Range 2 Cold Start 600W, 230 Vac 1750W (50%), 230 Vac 3500W (100%), 230 Vac 600W, 480 Vac 2500W (50%), 480 Vac 5000W (100%), 480 Vac Min 47 180 320 Airflow Front to Back Typ 50/60 Max 63 264 528 170 280 150 260 13 30 Units Hz Vac Vac Vac Vac Vac Vac Arms Apk 0.992 0.998 0.998 0.910 0.995 0.995 OVERALL CHARACTERISTICS Parameter Conditions Min Typ Max Units Range 1 3500 Output Power W Range 2 5000 700W (20%), 230Vac 89.5 Efficiency, Range 1 1750W (50%), 230Vac 93.6 3500W (100%), 230Vac 94.2 % 500W (20%), 230Vac 92.6 Efficiency, Range 2 2500W (50%), 230Vac 95.4 5000W (100%), 230Vac 95.4 The following curves represent the achieved efficiency performance for the D2U5T-H3-5000-380-Hu3C product compared against a recognized industry standard for efficiency rating. The D2U5T-H3-5000-380-HU3C offers performance in excess of the industry standard limit as a required percentage of loading. Test methodology as per Ecova Generalized Test Protocol for Calculating the Energy Efficiency of Internal AC-DC and DC-DC Power Supplies Revision 6.7 CB Test Certificate and Test Report www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 1 of 8 D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter EFFICIENCY PERFORMANCE CURVES OUTPUT VOLTAGE CHARACTERISTICS Output Parameter 380V Output Current Voltage Set Point Voltage Droop 3.3VSB 5VSB Line Regulation Ripple Voltage & Noise1 Load Capacitance Voltage Set Point Line and Load Regulation Ripple Voltage & Noise2 Output Current Load Capacitance Voltage Set Point Line and Load Regulation Ripple Voltage & Noise2 Output Current Load Capacitance Min 0 0 Conditions Range 1 Range 2 @4.6A Range 1 @6.67A Range 2 Min to Max Current, Range 1 Min to Max Current, Range 2 Typ Max 9.2 13.34 380 380 7 11 0.1 1 100 Vdc 1000 3.3 3.14 3.46 75 6 1000 20MHz Bandwidth 0 20 5 4.76 20MHz Bandwidth 0 20 Units Adc 5.24 100 4 1000 % Vp-p μF Vdc mVp-p A μF Vdc mVp-p A μF 1 Ripple and noise are measured with 22nF (U2J 630V) ceramic + 15 μF (UCC KXJ) of electrolytic de-coupling capacitors at the output connector load side. A short coaxial cable with 50ohm scope termination is used. 2 Ripple and noise are measured with 0.1 uF of ceramic capacitance and 10 uF of tantalum capacitance across the power supply outputs at the output connector load side. A short coaxial cable with 50ohm scope termination is used. www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 2 of 8 D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter OUTPUT CHARACTERISTICS Parameter Startup Time Transient Response Current sharing accuracy (up to 3 in parallel) Hot Swap Transients Holdup Time GENERAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Altitude Shock Sinusoidal Vibration MTBF Weight Safety Approvals Input Fuses Material Flammability PROTECTION CHARACTERISTICS Output Parameter Over-temperature (intake) Over Voltage Over Current Range 1 380V Over Current Range 2 Over Voltage 3.3VSB Over Current Over Voltage 5VSB Over Current Conditions AC ramp up 380V, 50-100% load step, 0.1A/μs di/dt 5VSB, 50-100% load step, 1A/μs di/dt 3.3VSB, 50-100% load step, 1A/μs di/dt 380V @100% load All outputs within regulation 380V @100% load VSB @100% Load Conditions Non-condensing Non-condensing (Without derating at 40°C) (Without derating at 50°C) 30G non-operating 0.5G, 5 – 500 Hz Calculated per Telcordia SR-332 @40°C Min Typ Max 3 15 250 165 +/-10 25 500 Min -40 -15 10 5 Units s Vp-p mVp-p mVp-p % ms Typ Max 70 50 90 90 3000 1800 Units °C °C % % m hrs kg 220K 7 CAN/CSA C22.2 No 60950-1-07, Am.1:2011, Am 2:2014 ANSI/UL 60950-1-2014 IEC60950-1:2005 (2nd Ed.), Am 1:2009 + Am 2:2013 EN 60950-1:2006+A11:2009 +A1:2010 +A12:2011 +A2:2013 Power Supply has one internal 16A/500V fast blow fuse on each of the three AC line inputs. UL 94V0 Conditions Auto-restart Latching Hiccup or Latching Hiccup or Latching Latching Hiccup Latching Hiccup Min 57 418 105 105 3.9 6.3 5.6 4.2 Typ 60 Max 63 445 130 130 4.3 9 6.0 6 Units °C V % % V A V A www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 3 of 8 D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter EMISSIONS AND IMMUNITY Characteristic Input Current Harmonics Conducted Emissions Radiated Emissions (in the application) ESD Immunity Radiated Field Immunity Electrical Fast Transients/Burst Immunity Surge Immunity RF Conducted Immunity Magnetic Field Immunity Standard IEC/EN 61000-3-2 FCC 47 CFR Parts 15 CISPR 22 EN55022 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 Voltage Dips & Interruptions IEC/EN 61000-4-11 Voltage imbalance (Circuit will stop when input voltage imbalance exceeds 8% for more than 100ms. Unit will restart when imbalance returns below 8%) ISOLATION CHARACTERISTICS Parameter Insulation Safety Rating/Test Voltage Conditions Input to Output – Reinforced Input to Chassis – Basic Output to Chassis – Basic Compliance Complies Class A, 6dB margin Class A, 6dB margin Level 3 criteria A Level 3 criteria B Level 3 criteria A Level 3 criteria A Level 3 criteria A 3 A/m criteria B 400Vrms Input Voltage 54V & VSB Outputs, Performance a) 100% load, Phase 0°, Dip 100% Duration 10ms 50% load, Phase 0°, Dip 100% Duration 20ms 54V & VSB Outputs, Performance b) 100% load, Phase 0°, Dip 100% Duration >10ms Any Load, Phase 0°, Dip 100% Duration >100ms Any valid Input Voltage, any load 54V & VSB Outputs, Performance a) Dip 30% on single Phase or Line, Duration 100ms 54V & VSB Outputs, Performance b) Dip 30% on single Phase or Line, Duration >100ms Min 3000 1500 1150 Typ Max Units Vrms Vrms Vrms www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 4 of 8 D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter STATUS INDICATORS (LEDs) Status Indicators AC input voltage is not present AC present and within the required operational range Standby – ON; Main Output – OFF (disabled) AC present, but its level is not within the required operational range Input OK (Green) Output OK (Green) Fault4 (Yellow) Off Off Off Solid Green Blinking Off Blinking Green at 1Hz rate Off (0.5s on, 0.5s off) Off Blinking Green at 1Hz rate Off (0.5s on, 0.5s off) When hot-unplugging the power supply from a power shelf3 AC present and within the required operational range Standby – ON and within the specified regulation range Main Output – ON and within the specified regulation range AC present and within the required operational range Standby – ON and within the specified regulation range Main Output – ON and within the specified regulation range Power supply is in a power limit or in an overcurrent condition. Off Solid Green Solid Green Off Solid Green Solid Green On Any warning Levels (Input UV/OV, OC, Inlet Temp, Output and STBY OV/UV, OC, OTP, FAN) No Change No Change Blinking 1Hz Any Fault Levels (Input UV/OV, OC, Inlet Temp, Output and STBY OV/UV, OC, OTP, FAN) Depends on PS Status Depends on PS Status Depends on PS Status 3 The Input OK LED blinks to indicate that there is still energy inside the power supply until the input bulk capacitors are completely discharged or the housekeeping circuit is shut down. 4 The Fault LED and PS Fault signal shall be turned on to indicate that there is one or more of the following internal faults currently detected inside the power supply: VSB out of range Output stage OT Fan fault ORING fault (Output voltage less than bus voltage) OC shutdown OT shutdown OV shutdown Input stage OT Fault induced shutdown occurred Thermal sensor fault Vout out of range PFC Boost Vbulk fault As soon as all of the above faults are removed and the power supply operates normally, the Fault LED and PS Fault signal shall be turned off. LED Definition: Three LEDs shall be located on the front faceplate; these are: LED Status Input OK = ON Output OK = ON Fault = ON www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 5 of 8 D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter Control Signals Signal (I/O) PS_ON_H Description Internal 10K pull-up resistor to internal VDD.5 Leaving signal pin open = Main Output ON Tying signal pin to GND = Main Output OFF. PS_KILL Short pin; internal 10K pull-up resistor to internal VDD.5 Leaving signal pin open = All Outputs off Tying signal pin to GND = All Outputs enabled. PS_FAULT_L Internal 10K pull-up resistor to internal VDD.5 PSU Fault Status PWR_GOOD_H STBY_SEL_IN Internal 10K pull-up resistor to internal VDD.5 Main Output Status OK Internal 10K pull-up resistor to internal VDD.5 Leaving signal pin open = +5VSTBY Tying signal pin to GND = +3V3STBY AC_OK_H Internal 10K pull-up resistor to internal VDD.5 AC OK Status SMB_ALERT_L Internal 10K pull-up resistor to internal VDD.5 SMB Alert signal output 5 VDD depends on Standby Voltage selection of either 3.3V or 5V. OUTPUT CONNECTOR Connector: FCI Power Blade Part # 51915-424 www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 6 of 8 D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter OUTPUT CONNECTOR & SIGNAL PIN ASSIGNMENT Connector: FCI Power Blade Part # 51915-424 Power Blade Number Signal P13 -VOUT_PRE-CHARGE P12 -VOUT P11 +VOUT_PRE-CHARGE P10 +VOUT P9 Not fitted P8 Not fitted P7 AC1 P6 Not fitted P5 AC2 P4 Not fitted P3 AC3 P2 Not fitted P1 GND Signal Pin Number Signal A1 A1 A2 PS_FAULT_L A3 A0 A4 PS_PRESENT A5 SCL A6 SGND B1 A2 B2 PS_ON_H B3 +VSB B4 SDA B5 PS_KILL B6 C1 C2 C3 C4 C5 C6 D1 D2 D3 D4 D5 D6 VSB_RTN STBY_SEL_IN AC_OK_H +VSB +VSB VSB_RTN VSB_RTN SMB_ALERT_L PWR_GOOD_H +VSB +VSB VSB_RTN VSB_RTN Function Hot Swap Pre Charge 380Vdc Return Hot Swap Pre Charge 380Vdc AC Line Voltage Ph 1 AC Line Voltage Ph 2 AC Line Voltage Ph 3 Safety Ground Function I2C Address Bit 1 Signal PSU Fault Status I2C Address Bit 0 Signal PSU Seated into Connector I2C Clock Signal Signal ground (return) I2C Address Bit 2 Signal Enable PSU +3.3V/5V STBY Out I2C Data Signal Enable PSU Shortest pin of the connector VSTBY_RTN Selects +3V3 or +5VSTBY AC(DC) OK Status +3.3V/5V STBY Out +3.3V/5V STBY Out VSTBY_RTN VSTBY_RTN SMB Alert signal output Power OK Status +3.3V/5V STBY Out +3.3V/5V STBY Out VSTBY_RTN VSTBY_RTN Signal Direction Output Output Output Output Input Input Input Input Signal Direction Input Output Input Output Bi-Directional Output Input Input Output Bi-Directional Input Output Input Output Output Output Output Output Output Output Output Output Output Output MATING CONNECTOR Supplier Press Fit, Straight FCI Press Fit, Right Angle Solder Straight Solder Right Angle 51938-826LF www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 7 of 8 D2U5T-H3-5000-380-HU3C AC-DC Three Phase Power Converter MECHANICAL DIMENSIONS 455.90 ±0.25 ±0.25 129.60 486.60 REF 4.97 ±0.30 22.89 ±0.50 ±0.40 77.21 (2X) ±0.35 ±0.50 18.00 151.60 9.00 ±0.25 11.00 ±0.35 (2X) ±0.40 84.50 66.50 REF ±0.50 6.00 67.00 141.60 1.50 ±0.25 #6-32 CAPTIVE SCREW (2X) ±0.75 Dimensions: 5.1" x 18"x 3.3" [129.5mm x 455.9mm x 84.5mm] OPTIONAL ACCESSORIES Description Part Number 12V D2U5T-380 Output Connector Card D2U5T-380-CONC APPLICATION NOTES Document Number Description Link ACAN-62 D2U5T-380-CONC Customer Interface Connector Card http://power.murata.com/datasheet?/data/apnotes/acan-62.pdf ACAN-63 PMBusTM Communication Protocol for: D2U5T-H3-5000-380-Hu3C http://power.murata.com/datasheet?/data/apnotes/acan-63.pdf Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048 -1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2016 Murata Power Solutions, Inc. www.murata-ps.com/support D2U5T-H3-5000-380-HU3C.A02 Page 8 of 8