Reed Sensors Flange Mounting Sensor > 59125 59125 Pinned Flange Sensor + 57125 Actuator Description The 59125 is a flange mounting reed sensor 28.57mm x 19.05mm x 6.35mm (1.125” x 0.750” x 0.259”) with integral terminal pins with a choice of normally open, normally open high voltage or normally closed contacts. It’s case design enables screw or adhesive mounting. It is capable of switching up to 265Vac/300Vdc at 10VA. The 59125 functions best with the matching actuator 57125-000. Note: The 57125 Actuator is sold separately. Features • Two-part magnetically operated proximity sensor • Moulded in terminal pins accept push on connector or wire wrap Agency Approvals Agency • Case design allows screw down or adhesive mounting • Customer defined sensitivity option Agency File Number Benefits E61760 • Hermetically sealed, magnetically operated contacts continue to operate long after optical and other technologies fail due to contamination Note: Contact Littelfuse for specific agency approval ratings. Dimensions • No standby power requirement • Operates through non-ferrous materials such as wood, plastic or aluminium Dimensions in mm (inch) 28.57 (1.125) 6.35 (.259) 9.53 (.375) 14.28 (.562) 15.88 (.625) Applications • Position and limit sensing • Security system switch • Linear actuators • Industrial process control 19.05 (.75) 3.43 (.135) 3.18x7.82 (.125x.308 LG.) SLOT 2 4.05 (.160) 28.57 (1.125) 6.10 (.240) 2.54 (.100) 14.28 (.562) SQ. PINS x 2 0.64 (.025) 2.54 (.100) 15.88 (.625) 3.18x7.82 (.125x.308 LG.) SLOT 2 6.35 (.250) © 2015 Littelfuse Revised: 10/29/15 Specifications are subject to change without notice. 9.53 (.375) 6.35 (.250) 19.05 (.75) 3.43 (.135) littelfuse.com Reed Sensors Flange Mounting Sensor > 59125 59125 Pinned Flange Sensor + 57125 Actuator Electrical Ratings Normally Open Contact Type Switch Type Normally Open High Voltage Normally Closed 1 2 4 VA/Watt - max. 10 10 5 Vdc - max. Vac - max. Vdc - min. 200 140 250 300 265 400 175 120 200 Carry Adc - max. Aac - max. Adc - max. 0.5 0.35 1.2 0.4 0.30 1.4 0.25 0.18 1.5 Contact, Initial Insulation Ω - max. Ω - min. 0.2 1010 0.2 1010 0.2 109 Capacitance Contact pF - typ. 0.3 0.2 0.3 Temperature Operating °C -40 to +105 -20 to +105 -40 to +105 Contact Rating Voltage 4 Current 4 1 Switching 2 Breakdown Switching Resistance 5 3 2 Product Characteristics Operate Time 6 ms - max. 1.0 1.0 3.0 Release Time 6 ms - max. 1.0 1.0 3.0 11ms 1⁄2 sine G - max. 100 100 50 50-2000 Hz G - max. 30 30 30 Shock 7 Vibration 7 Notes: 1. Contact rating - Product of the switching voltage and current should never exceed the wattage rating. Contact Littelfuse for additional load/life information. 2. When switching inductive and/or capacitive loads, the effects of transient voltages and/or currents should be considered. Refer to Application Notes AN108A and AN107 for details. 3. Breakdown Voltage - per MIL-STD-202, Method 301. 4. Electrical Load Life Expectancy - Contact Littelfuse with voltage, current values along with type of load. 5. This resistance value is for 11.81mm wire length. Resistance changes when wire lengthens. 6. Operate (including bounce)/Release Time - per EIA/NARM RS-421-A, diode suppressed coil (Coil II). 7. Shock and Vibration - per EIA/NARM RS-421-A and MIL-STD-202. 8. For custom modifications to the wire length or size, or adding a special connector, please contact Littelfuse. Sensitivity Options (Using 57125 Actuator) Select Option Switch Type S T U Distance Pull-In AT Activate Distance Pull-In AT Activate mm (inch) mm (inch) Range Range Average Average V Pull-In AT Range Activate Distance mm (inch) Average Pull-In AT Range Activate Distance mm (inch) Average 1 Normally Open 12-18 12.5 (.492 17-23 11.3 (.445) 22-28 9.8 (.385) 27-33 8.9 (.350) 2 High Voltage -- -- 17-23 11.3 (.445) 22-28 9.8 (.385) 27-33 8.9 (.350) 4 Normally Closed 15-20 8.0 (.315) 20-25 7.2 (.283) 25-30 5.9 (.233) -- -- Note: 1. Pull-In AT Range: These AT values are the bare reed switch AT before modification. 2. The activation distance is average value on the final sensor assembly © 2015 Littelfuse Revised: 10/29/15 Specifications are subject to change without notice. D littelfuse.com Reed Sensors Flange Mounting Sensor > 59125 59125 Pinned Flange Sensor + 57125 Actuator Part Numbering System Sensor: 59125 - X - X - 00 - 0 Actuator: 57125 - 000 Series Series Switch Type 1, 2, or 4 Standard Actuator 000 Sensitivity S, T, U, or V Note: The 57125 Actuator is sold separately. Packaging Packaging Option Packaging Specification Bulk © 2015 Littelfuse Revised: 10/29/15 Specifications are subject to change without notice. Bulk Quantity 500 Quantity & Packaging Code N/A Taping Width N/A littelfuse.com