Fuse Filtered - 66-67-BFF Series, Fast-on Terminals, For Medical or General Purpose Applications

Fused Filtered
Power
Entry Modules
For Medical or General Purpose Applications
■
■
■
■
■
■
Specifications
Model*
66-XXX-020-1-11
66-XXX-020-1-12
66-XXX-020-0-11
66-XXX-020-4-11
66-XXX-020-0-12
66-XXX-020-4-12
66-XXX-040-1-11
66-XXX-040-1-12
66-XXX-040-0-11
66-XXX-040-4-11
66-XXX-040-0-12
66-XXX-040-4-12
66-XXX-060-1-11
66-XXX-060-1-12
66-XXX-060-0-11
66-XXX-060-4-11
66-XXX-060-0-12
66-XXX-060-4-12
67-XXX-020-1-11
67-XXX-020-1-12
67-XXX-020-0-11
67-XXX-020-4-11
67-XXX-020-0-12
67-XXX-020-4-12
67-XXX-040-1-11
67-XXX-040-1-12
67-XXX-040-0-11
67-XXX-040-4-11
67-XXX-040-0-12
67-XXX-040-4-12
67-XXX-060-1-11
67-XXX-060-1-12
67-XXX-060-0-11
67-XXX-060-4-11
67-XXX-060-0-12
67-XXX-060-4-12
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
0.01mA
250VAC
2A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
4A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
6A
0.075mA
0.1mA
0.075mA
0.1mA
0.005mA
125VAC
2A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
4A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
6A
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
F(S) = Fast-on or (Solder lug terminals)
0.035mA
0.05mA
0.035mA
0.05mA
■
■
■
■
Medical equipment
Electronic equipment
Digital equipment
Industrial equipment
■
■
■
Telecommunications equipment
Measuring and testing instruments
Personal computers
and peripherals
66/67-BFF(S)-XXX-0-X and
66/67-BFF(S)-XXX-4-X Filters
Circuit Diagrams
66/67-BFF(S)-XXX-1-X Filter
L
L
L
L
L1
R
L1
CX
E
E
R
CY
CX
E
E
LOAD
■
Applications
LINE
■
Tested and found to be
IAW VDE 0565 Part 3.
Metric and North American fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Fast-on terminations or solder lug terminations
Metal case provides effective EMI shielding
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitance
Reduces the line to ground capacitance in order
to meet patient care requirements
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF37)
LOAD
■
LINE
66-67-BFF/66-67-BFS Series
Features
CY
N
N
CY
Capacitance
none
330pF
470pF
330pF
470pF
± 20%
± 20%
± 20%
± 20%
none
330pF
470pF
330pF
470pF
± 20%
± 20%
± 20%
± 20%
none
330pF
470pF
330pF
470pF
± 20%
± 20%
± 20%
± 20%
none
330pF
470pF
330pF
470pF
± 20%
± 20%
± 20%
± 20%
none
330pF
470pF
330pF
470pF
± 20%
± 20%
± 20%
± 20%
none
330pF
470pF
330pF
470pF
± 20%
± 20%
± 20%
± 20%
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
CX
0.1uF
0.22uF
0.1uF
N
N
Inductance
(L1)
Temperature
Rise (Max.)
6.5mH
40°C
2.4mH
45°C
1.6mH
45°C
6.5mH
40°C
2.4mH
45°C
1.6mH
45°C
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF36
Fused Filtered
Power
Entry Modules
For Medical or General Purpose Applications
66-67-BFF/66-67-BFS Series
66-67-BFF/66-67-BFS Series
Dimensions
Temperature Characteristics
120
1.738 (44.2)
2.32 (59)
.098 (2.5)
1.101 (28)
100
Current (%)
Fuse cover
1.376
(35)
80
1.298
(33)
60
1.416±.008
(36±0.2)
40
1.29
(32.8)
2 - .13 +.008
-.004
(2 - 3.3+0.2
-0.1)
Hole
0.252 (6.4)
1.14
(29)
1.616 (41.1)
* Alternate Terminal for 66/67-BFS-Solder Lug Terminal
Fast-on tab#250
t= .031 (0.8)
20
0.158
(4.0)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
2.249 (L:57.2)
Common Mode
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
90
90
80
80
70
70
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
60
2 Amp
40
30
60
2 Amp
50
30
0
0.1
0.2
0.5
10
1
2
5
Frequency (MHz)
10
20
0
0.1
50
80
80
70
70
Insertion Loss (dB)
90
60
2 Amp
50
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0.075 and 0.1 mA Leakage Current
0.075 and 0.1 mA Leakage Current
90
40
30
60
2 Amp
50
40
30
20
20
6 Amp
4 Amp
10
0
0.1
6 Amp
6 Amp
4 Amp
4 Amp
40
20
20
10
50Ω
Level
Meter
50Ω
0.01 mA Leakage Current
0.01 mA Leakage Current
Insertion Loss (dB)
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
50
* General Tolerance:
±.020 (0.5)
* Metal Case
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
6 Amp
4 Amp
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF37