Fused Filtered Power Entry Modules For Medical or General Purpose Applications ■ ■ ■ ■ ■ ■ Specifications Model* 66-XXX-020-1-11 66-XXX-020-1-12 66-XXX-020-0-11 66-XXX-020-4-11 66-XXX-020-0-12 66-XXX-020-4-12 66-XXX-040-1-11 66-XXX-040-1-12 66-XXX-040-0-11 66-XXX-040-4-11 66-XXX-040-0-12 66-XXX-040-4-12 66-XXX-060-1-11 66-XXX-060-1-12 66-XXX-060-0-11 66-XXX-060-4-11 66-XXX-060-0-12 66-XXX-060-4-12 67-XXX-020-1-11 67-XXX-020-1-12 67-XXX-020-0-11 67-XXX-020-4-11 67-XXX-020-0-12 67-XXX-020-4-12 67-XXX-040-1-11 67-XXX-040-1-12 67-XXX-040-0-11 67-XXX-040-4-11 67-XXX-040-0-12 67-XXX-040-4-12 67-XXX-060-1-11 67-XXX-060-1-12 67-XXX-060-0-11 67-XXX-060-4-11 67-XXX-060-0-12 67-XXX-060-4-12 Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) 0.01mA 250VAC 2A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 4A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 6A 0.075mA 0.1mA 0.075mA 0.1mA 0.005mA 125VAC 2A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 4A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC F(S) = Fast-on or (Solder lug terminals) 0.035mA 0.05mA 0.035mA 0.05mA ■ ■ ■ ■ Medical equipment Electronic equipment Digital equipment Industrial equipment ■ ■ ■ Telecommunications equipment Measuring and testing instruments Personal computers and peripherals 66/67-BFF(S)-XXX-0-X and 66/67-BFF(S)-XXX-4-X Filters Circuit Diagrams 66/67-BFF(S)-XXX-1-X Filter L L L L L1 R L1 CX E E R CY CX E E LOAD ■ Applications LINE ■ Tested and found to be IAW VDE 0565 Part 3. Metric and North American fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminations or solder lug terminations Metal case provides effective EMI shielding Provides susceptibility protection without the leakage current associated with line-to-ground capacitance Reduces the line to ground capacitance in order to meet patient care requirements Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF37) LOAD ■ LINE 66-67-BFF/66-67-BFS Series Features CY N N CY Capacitance none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% none 330pF 470pF 330pF 470pF ± 20% ± 20% ± 20% ± 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 CX 0.1uF 0.22uF 0.1uF N N Inductance (L1) Temperature Rise (Max.) 6.5mH 40°C 2.4mH 45°C 1.6mH 45°C 6.5mH 40°C 2.4mH 45°C 1.6mH 45°C 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF36 Fused Filtered Power Entry Modules For Medical or General Purpose Applications 66-67-BFF/66-67-BFS Series 66-67-BFF/66-67-BFS Series Dimensions Temperature Characteristics 120 1.738 (44.2) 2.32 (59) .098 (2.5) 1.101 (28) 100 Current (%) Fuse cover 1.376 (35) 80 1.298 (33) 60 1.416±.008 (36±0.2) 40 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 66/67-BFS-Solder Lug Terminal Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 2.249 (L:57.2) Common Mode Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 90 80 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 50Ω 60 2 Amp 40 30 60 2 Amp 50 30 0 0.1 0.2 0.5 10 1 2 5 Frequency (MHz) 10 20 0 0.1 50 80 80 70 70 Insertion Loss (dB) 90 60 2 Amp 50 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0.075 and 0.1 mA Leakage Current 0.075 and 0.1 mA Leakage Current 90 40 30 60 2 Amp 50 40 30 20 20 6 Amp 4 Amp 10 0 0.1 6 Amp 6 Amp 4 Amp 4 Amp 40 20 20 10 50Ω Level Meter 50Ω 0.01 mA Leakage Current 0.01 mA Leakage Current Insertion Loss (dB) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 50 * General Tolerance: ±.020 (0.5) * Metal Case 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 6 Amp 4 Amp 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF37