High Frequency Attenuation - 60-BHS Series

Power Entry Modules
High Frequency Attenuation
60-BHS Series
Features
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
PCB mounting types available (see page PF48)
PCB mounting minimizes space and provides
economical installation
Excellent filtering characteristics for high frequencies
Earth coil standard
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF21)
Applications
■
■
■
■
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHS-010-3-11
250VAC
E
CY
2
4
L2
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
60-BHS-010-5-4
0.35mA
250VAC
2200pF ± 20%
Temperature
Rise (Max.)
0.1uF ± 20%
6mH
18.3uH
30°C
2.4mH
18.3uH
30°C
1.2mH
18.3uH
30°C
.53mH
18.3uH
45°C
0.1uF ± 20%
0.1uF ± 20%
.047uF ± 20%
2A
60-BHS-020-5-11
0.50mA
3300pF ± 20%
60-BHS-020-5-4
0.1uF ± 20%
.047uF ± 20%
60-BHS-030-3-11
0.35mA
250VAC
2200pF ± 20%
0.1uF ± 20%
.047uF ± 20%
3A
60-BHS-030-5-11
0.50mA
3300pF ± 20%
60-BHS-030-5-4
0.1uF ± 20%
.047uF ± 20%
60-BHS-060-3-11
60-BHS-060-3-4
Inductance
(L1)
(L2)
.047uF ± 20%
60-BHS-020-3-11
60-BHS-030-3-4
CX
.047uF ± 20%
1A
60-BHS-010-5-11
60-BHS-020-3-4
CY
L1
CX
Specifications
60-BHS-010-3-4
3
1
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
Model
Circuit Diagram
0.35mA
250VAC
2200pF ± 20%
6A
60-BHS-060-5-11
60-BHS-060-5-4
0.1uF ± 20%
.047uF ± 20%
0.50mA
3300pF ± 20%
0.1uF ± 20%
.047uF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF20
Power Entry Modules
High Frequency Attenuation
60-BHS Series
Temperature Characteristics
.098
(2.5)
1.967 (50)
1.573 (40)
120
.885
(22.5)
Current (%)
100
1.180 (30)
60
.779 1.180
(19.8) (30)
Panel cutout dimensions
mounts from backside
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
Dimensions in inches (mm)
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-BHS-XXX-X-11
90
50Ω
50Ω
Level
Meter
50Ω
60-BHS-XXX-3-11
80
80
60-BHS-010-X-11
70
Insertion Loss (dB)
Insertion Loss (dB)
2- .142
(3.6)
1.573 (40)
20
60-BHS-020-X-11
60
50
40
60-BHS-030-X-11
30
60-BHS-060-X-11
70
60-BHS-010-3-11
60
50
60-BHS-020-3-11
40
60-BHS-030-3-11
30
60-BHS-060-3-11
20
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
60-BHS-XXX-X-4
90
80
0.5
1
2
5
10
20
50
60-BHS-XXX-3-4
80
Insertion Loss (dB)
60-BHS-010-X-4
70
60-BHS-020-X-4
60
50
40
60-BHS-030-X-4
30
60-BHS-060-X-4
70
60-BHS-010-3-4
60
50
60-BHS-020-3-4
60-BHS-030-3-4
30
60-BHS-060-3-4
20
10
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
*
40
20
0
0.1
0.2
Frequency (MHz)
Frequency (MHz)
Insertion Loss (dB)
.031 (.8)
.5
R4
.865
(22)
40
90
1.180
(30)
2- .142
(3.6)
80
90
1.534 (39)
1.389
(35.3)
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF21