Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards PCB mounting types available (see page PF46) Length under tab is shortened for small spaces Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF19) UL approved low leakage version also available ■ ■ ■ Specifications Rated Voltage (@ 50/60Hz) Rated Current 60-BPF-010-3-2 60-BPF-010-3-4 250VAC E CY 2 4 Leakage Current (Max.) CY Capacitance 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 60-BPF-010-5-4 0.35mA 250VAC 2200pF ± 20% Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% .022uF ± 20% .022uF ± 20% .047uF ± 20% 2A 60-BPF-020-5-2 0.50mA 3300pF ± 20% 60-BPF-020-5-4 .022uF ± 20% .047uF ± 20% 60-BPF-030-3-2 0.35mA 250VAC 2200pF ± 20% .022uF ± 20% .047uF ± 20% 3A 60-BPF-030-5-2 0.50mA 3300pF ± 20% 60-BPF-030-5-4 .022uF ± 20% .047uF ± 20% 60-BPF-060-3-2 60-BPF-060-3-4 Inductance (L1) .047uF ± 20% 60-BPF-020-3-2 60-BPF-030-3-4 CX .047uF ± 20% 1A 60-BPF-010-5-2 60-BPF-020-3-4 CY L1 E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units Model 3 1 CX Applications ■ Circuit Diagram 0.35mA 250VAC 2200pF ± 20% 6A 60-BPF-060-5-2 60-BPF-060-5-4 .022uF ± 20% .047uF ± 20% 0.50mA 3300pF ± 20% .022uF ± 20% .047uF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF18 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series 60-BPF Fast-on Terminals Temperature Characteristics 120 1.463 (37.2) 1.967 (50) 1.317 (33.5) 1.573 (40) .885 (22.5) Current (%) 100 2- .142 (3.6) 80 .047 (1.2) .232 (5.9) .024 (.6) .5 R4 .865 (22) 2- .142 (3.6) 1.573 (40) 40 * General tolerance ± .012 (.3) .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) 1.180 (30) 60 .991 (25.2) .590 (15) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BPF-010;-020 80 70 70 Insertion Loss (dB) Insertion Loss (dB) 60-BPF-010-3-X 60 50 60-BPF-020-3-X 40 30 20 10 60 60-BPF-010-X-4 50 40 30 60-BPF-020-X-4 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 5 10 20 50 20 50 60-BPF-030;-060 60-BPF-030;-060 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 2 Frequency (MHz) 80 60-BPF-030-3-X 50 40 60-BPF-060-3-X 30 20 60 50 40 60-BPF-030-X-4 30 60-BPF-060-X-4 20 10 10 0 0.1 50Ω Level Meter 50Ω 60-BPF-010;-020 80 0 0.1 50Ω 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF19