Dual Stage - 62-MMF Series

Power Line Filters
Dual Stage
62-MMF Series
Features
■
■
■
■
■
■
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Epoxy molded for reliability
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF73)
Circuit Diagram
62-MMF-XXX-7-11
1
L1
CX
R
Applications
■
■
■
■
■
Model
62-MMF-030-7-11
62-MMF-050-7-11
Rated
Current
Leakage Current
(Max.)
250VAC
5A
3A
CX
CY
CY
2
Rated Voltage
(@ 50/60Hz)
250VAC
3
L1
CY
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Specifications
CX
CY
E
4
.7mA
CY1
3300pF
Capacitance
CY2
1000pF
CX
0.1uF
Inductance
(L1) (2X)
Temperature
Rise (Max.)
.7mA
3300pF
1000pF
0.1uF
2.9mH
30°C
3.7mH
30°C
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF72
Power Line Filters
Dual Stage
62-MMF Series
Temperature Characteristics
3.291 (83.7)
120
.786 (20)
.315
(8)
Fast-on tab
#250
2.937 (74.7)
Current (%)
100
80
.315
(8)
1.258
(32)
2 – .197 (5)
1.998
(50.8)
60
.610
(15.5)
40
.610
(15.5)
2.497 (63.5)
1.258 (32)
20
Dimensions in inches (mm)
0
20
30
40
50
60
70
80
90
Ambient Temperature (°C)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
Oscillator
50Ω
62-MMF
90
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
90
1
3
Filter
2
4
50Ω
Level
Meter
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
50Ω
Level
Meter
50Ω
62-MMF
60
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
10
0
0.1
50Ω
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF73