PSMHBU60 SERIES 60W Medical AC/DC Switching Power Supplies Rev A Wall Industries, Inc. FEATURES • RoHS Compliant • Open Frame Design • Class I • 90-264VAC Input Voltage Range • 60 Watts Output Power • Over Current and Over Voltage Protection • Single Outputs • < 0.5W No Load Power Consumption • Up to 89% High Efficiency • ANSI/AAMI ES 60601-1: 2005 (UL/cUL 3rd Edition), • Free Air Convection Cooling • 100% Burn-in Tested EN 60601-1:2006 (TUV/T-mark 3rd Edition) • Input to Output: 2MOPP DESCRIPTION The PSMHBU60 series of class I medical AC/DC switching power supplies provides 60 Watts of continuous output power in a 3.98” x 2.00” x 1.00” open frame package. This series consists of single output models with a wide input voltage range of 90~264VAC. Some features include high efficiency up to 89%, 2MOPP insulation, < 0.5W no load power consumption, and over current and over voltage protection. All models meet FCC Part-18 class B and CISPR-11 EN55011 class B emission limits. This series also has ANSI/AAMI ES 60601-1: 2005 (UL/cUL 3rd edition) and EN 60601-1:2006 (TUV/T-mark 3rd edition) medical approvals. All models are RoHS compliant and have been 100% burn-in tested. Size: 3.98 x 2.00 x 1.00 inches 101.0 x 50.8 x 25.4 mm APPLICATIONS • Blood Pressure Systems • Portable Medical Devices • ECG Machines MODEL SELECTION TABLE Output Voltage (1) Output Current Total Regulation Output Power PSMHBU60-105 12 ~ 13 VDC 5.00 ~ 4.61 A 5% 60W PSMHBU60-106 13 ~ 16 VDC 4.61 ~ 3.75 A 5% 60W 16 ~ 21 VDC 3.75 ~ 2.85 A 5% 60W 21 ~ 27 VDC 2.85 ~ 2.22 A 3% 60W PSMHBU60-109 27 ~ 33 VDC 2.22 ~ 1.81 A 3% 60W PSMHBU60-110 33 ~ 40 VDC 1.81 ~ 1.50 A 3% 60W Model Number Input Voltage Range PSMHBU60-107 100~240 VAC PSMHBU60-108 NOTES 1. The output voltage is specified as a range (ex: 33~40VDC); the customer must specify what they would like the output voltage set at. 2. Recommended to be used on metal chassis. DERATING 120 Output Power (%) 100 80 60 40 20 0 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) 01/31/2013 Wall Industries, Inc. • 5 Watson Brook Road, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 1 of 3 Rev A Wall Industries, Inc. PSMHBU60 SERIES 60W Medical AC/DC Switching Power Supplies SPECIFICATIONS: PSMHBU60 SERIES All specifications are based on 25°C, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. SPECIFICATION TEST CONDITIONS Min Typ Max Unit INPUT SPECIFICATIONS Input Voltage Safety Approvals Input Voltage Range 100 240 Operating Input Voltage Range 90 47 264 63 Input Frequency 100VAC, full load 240VAC, full load 100VAC, full load, 25°C, cold start Input Current Inrush Current No Load Power Consumption 1.62 0.72 Hz A 31 230VAC, full load, 25°C, cold start 230VAC, no load VAC 62 0.5 A W OUTPUT SPECIFICATIONS Output Voltage Line Regulation Load Regulation Output Power Output Current Ripple & Noise (peak to peak) Hold-up Time Start-up Time Transient Response Time Temperature Coefficient See Table LL to HL, full load 230VAC 90VAC, full load 110VAC, full load 100VAC, full load 100VAC, Full load to half load 0~50°C 1 5 60 See Table 1 % % W -0.04 2 4 +0.04 % ms s ms %/°C 112 110 132 150 % % 78.4 6492 2121 50 89 % 12 0.3 PROTECTION Over Voltage Protection Over Current Protection GENERAL SPECIFICATIONS Efficiency Dielectric Withstanding Voltage Isolation Resistance Leakage Current 230 VAC, full load Primary to Secondary (2MOPP Insulation) Primary to PE Test Voltage = 500VDC 240VAC/60Hz VDC 0.25 MΩ mA ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Cooling MTBF Derating linearly from 100% Load at 40°C to 50% load at 70°C MIL-HDBK-217F, 25°C 0 -40 0 0 +70 +85 95 95 Up to 3000m Free air convection 100,000 °C °C % % hours PHYSICAL SPECIFICATIONS Weight Dimensions (L x W x H) Input Connector Output Connector 4.9oz (140g) 3.98 x 2.00 x 1.00 inches (101.0 x 50.8 x 25.4 mm) Mates with Molex housing 09-50-3031/35977-0300 and Molex 2478/35922 series crimp terminal Mates with Molex housing 09-50-3061/35977-0600 and Molex 2478/35922 series crimp terminal SAFETY & EMC Safety Approvals EMI Requirements for CISPR-11 EMI Requirements for FCC PART-18 01/31/2013 220VAC 110VAC ANSI/AAMI ES 60601-1: 2005 (UL/cUL 3rd edition); EN 60601-1:2006 (TUV/T-mark 3rd edition); CE B Class B Class Wall Industries, Inc. • 5 Watson Brook Road, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 2 of 3 PSMHBU60 SERIES 60W Medical AC/DC Switching Power Supplies Rev A Wall Industries, Inc. MECHANICAL DRAWING Unit: inches (mm) 1.00 (25.4) 0.18 (4.6) PIN CONNECTIONS PIN 1 2 3 4 5 6 3.98±0.02 (101.0±0.5) ASSIGNMENT OUT OUT OUT RTN RTN RTN 3.66±0.02 (93.0±0.5) C7 L2 C6 T1 C20 C5 P2 1 C19 0.70±0.02 (17.6±0.5) IC2 C21 J2 MOV1 L1 L LED1 C18 ZD5 N P1 C16 C8 6 D4 SCR1 HS2 F2 DB1 C1 C25 C26 H2 H3 AC INPUT H1~H4: Ø4.0 (MOUNTING HOLES) PITCH = 0.16 (3.96) 1.18±0.02 (29.8±0.5) HS1 C2 TH1 T2A250V PITCH = 0.31 (7.92) 1.68±0.02 (42.8±0.5) H4 C27 F1T2A250V 2.00±0.02 (50.8±0.5) H1 DC OUTPUT NOTES: 1. All dimensions are for reference only 2. Weight: Approximately 4.9oz (140g) 3. Input Connector: Mates with Molex housing 09-50-3031/35977-0300 and Molex 2478/35922 series crimp terminal 4. Output Connector: Mates with Molex housing 09-50-3061/35977-0600 and Molex 2478/35922 series crimp terminal COMPANY INFORMATION Wall Industries, Inc. has created custom and modified units for over 50 years. Our in-house research and development engineers will provide a solution that exceeds your performance requirements on-time and on budget. Our ISO9001-2008 certification is just one example of our commitment to producing a high quality, well-documented product for our customers. Our past projects demonstrate our commitment to you, our customer. Wall Industries, Inc. has a reputation for working closely with its customers to ensure each solution meets or exceeds form, fit and function requirements. We will continue to provide ongoing support for your project above and beyond the design and production phases. Give us a call today to discuss your future projects. Contact Wall Industries for further information: Phone: Toll Free: Fax: E-mail: Web: Address: 01/31/2013 (603)778-2300 (888)597-9255 (603)778-9797 [email protected] www.wallindustries.com 5 Watson Brook Rd. Exeter, NH 03833 Wall Industries, Inc. • 5 Watson Brook Road, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797 website: www.wallindustries.com • e-mail: [email protected] Page 3 of 3