MFW02

MFW02 SERIES
DC/DC CONVERTER 2W, Regulated Output, DIP Package
FEATURES
►Smallest Encapsulated 2W Converter
►Ultra-compact DIP-8 Package
►Wide 2:1 Input Voltage Range
►Fully Regulated Output Voltage
►I/O Isolation 1500 VDC
►Operating Ambient Temp. Range -40°C to +80°C
►No Min. Load Requirement
►Overload and Short Circuit Protection
►UL/cUL/IEC/EN 60950-1 Safety Approval & CE Marking
PRODUCT OVERVIEW
The MINMAX MFW02 series is the latest generation of high performance dc-dc converter modules setting a new standard concerning power density. The
product offers a full 2W isolated dc-dc converter within an encapsulated DIP-8 package which occupies only 0.3 in2 of PCB space. There are 28 models
available for 5, 12, 24, 48VDC input with wide 2:1 input voltage range. Further features include over current, short circuit protection and no min. load
requirement as well. An high efficiency allows operating temperatures range of -40℃ to +80℃.
These DC/DC converters offer an economical solution for many cost critical applications in battery-powered equipment, instrumentation, distributed power
architectures in communication, industrial electronics, energy facilities and many other critical applications where PCB space is limited.
Model Selection Guide
Model
Number
MFW02-05S033
MFW02-05S05
MFW02-05S12
MFW02-05S15
MFW02-05D05
MFW02-05D12
MFW02-05D15
MFW02-12S033
MFW02-12S05
MFW02-12S12
MFW02-12S15
MFW02-12D05
MFW02-12D12
MFW02-12D15
MFW02-24S033
MFW02-24S05
MFW02-24S12
MFW02-24S15
MFW02-24D05
MFW02-24D12
MFW02-24D15
MFW02-48S033
MFW02-48S05
MFW02-48S12
MFW02-48S15
MFW02-48D05
MFW02-48D12
MFW02-48D15
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
5
(4.5 ~ 10)
12
(9 ~ 18)
24
(18 ~ 36)
48
(36 ~ 75)
Output Current
Input Current
Max. capacitive
Load
Max.
@Max. Load
@No Load
mA
400
400
167
134
±200
±83
±67
400
400
167
134
±200
±83
±67
400
400
167
134
±200
±83
±67
400
400
167
134
±200
±83
±67
mA(typ.)
334
494
472
462
482
469
473
138
201
192
193
198
193
195
70
99
97
96
99
97
97
35
50
49
49
51
49
50
mA(typ.)
@Max. Load
μF
100
40
100#
100
27
100#
100
15
100#
100
8
100#
# For each output
E-mail:[email protected]
2016/03/18
REV:0
Tel:886-6-2923150
Page 1 of 5
Efficiency
(typ.)
%
79
81
85
87
83
85
85
80
83
87
87
84
86
86
79
84
86
87
84
86
86
79
83
85
86
82
84
84
MFW02 SERIES
DC/DC CONVERTER 2W, Regulated Output, DIP Package
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Short Circuit Input Power
Model
Min.
Typ.
Max.
5V Input Models
-0.7
---
12
12V Input Models
-0.7
---
25
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
5V Input Models
---
---
4.5
12V Input Models
---
---
9
24V Input Models
---
---
18
48V Input Models
---
---
36
---
---
0.5
All Models
Input Filter
Unit
VDC
W
Internal Capacitor
Output Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Dual Output, Balanced Loads
-----
-----
±1.5
±2.0
%Vnom.
Output Voltage Balance
Line Regulation
Vin=Min. to Max. @Full Load
---
---
±0.2
%
Io=0% to 100%
--------Asymmetrical load 25% / 100% FL
No minimum Load Requirement
±1.0
±5.0
%
%
--500
mV P-P
μsec
Output Voltage Setting Accuracy
Load Regulation
Cross Regulation (Dual)
Minimum Load
Ripple & Noise
Transient Recovery Time
Transient Response Deviation
0-20 MHz Bandwidth
-----
25% Load Step Change
Temperature Coefficient
Over Load Protection
Foldback
Short Circuit Protection
70
250
%
---
±3
±5
%
---
±0.01
±0.02
%/℃
---
180
---
%
Continuous, Automatic Recovery
General Specifications
Parameter
I/O Isolation Voltage
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
1 Seconds
1800
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
Switching Frequency
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
Safety Approvals
---
100
---
pF
100
---
---
KHz
4,226,000
---
---
Hours
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report)
Environmental Specifications
Parameter
Operating Ambient Temperature Range
(See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
2016/03/18
REV:0
Tel:886-6-2923150
Page 2 of 5
Conditions
Min.
Max.
Unit
Natural Convection
-40
+80
℃
+95
+125
95
℃
℃
% rel. H
260
℃
---50
--Natural Convection
---
MFW02 SERIES
DC/DC CONVERTER 2W, Regulated Output, DIP Package
EMC Specifications
Parameter
Standards & Level
EMI
Conduction & Radiation
EN55024
ESD
Radiated immunity
Fast transient (4)
Surge (4)
Conducted immunity
PFMF
EMS
Performance
EN55022, FCC part 15
Class A, B(5)
EN61000-4-2 Air ± 8kV , Contact ± 6kV
EN61000-4-3 10V/m
EN61000-4-4 ±2kV
EN61000-4-5 ±1kV
EN61000-4-6 10Vrms
EN 61000-4-8 3A/M
A
A
A
A
A
A
Power Derating Curve
100
Natural
Convection
20LFM
Output Power (%)
80
60
40
20
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature C
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
To meet EN61000-4-4 & EN61000-4-5 an external capacitor across the input pins is required.Suggested capacitor: 220μF/100V.
To meet EN55022 Class A,B an external filter, please contact MINMAX.
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
E-mail:[email protected]
2016/03/18
REV:0
Tel:886-6-2923150
Page 3 of 5
MFW02 SERIES
DC/DC CONVERTER 2W, Regulated Output, DIP Package
Package Specifications
Mechanical Dimensions
Pin Connections
1
-Vin
-Vin
4
+Vin
+Vin
5
+Vout
+Vout
6
No Pin
Common
7
-Vout
-Vout
0.50
[0.02]
2.54
[0.10]
4
Bottom View
7
6
7.62 [0.30]
1
14.0 [0.55]
3.19
[0.13]
7.62 [0.30]
5
3.19
[0.13]
►All dimensions in mm
2x2.54
[2x0.10]
►Tolerance: X.X±0.5
►Pin
Physical Characteristics
Case Size
:
14.0x14.0x8.0mm (0.55x0.55x0.31 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Tinned Copper
Weight
:
3.9g
E-mail:[email protected]
REV:0
Tel:886-6-2923150
Page 4 of 5
(inches)
(X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
14.0 [0.55]
2016/03/18
Dual Output
8.0 [0.31]
0.25 [0.01]
Single Output
3.1
[0.12]
Pin
diameter  0.5 ±0.05 (0.02±0.002)
MFW02 SERIES
DC/DC CONVERTER 2W, Regulated Output, DIP Package
Test Setup
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Technical Notes
Maximum Capacitive Load
The MFW02 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Overload Protection
To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited
duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back
into its specified range.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is commended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω
at 100 KHz) capacitor of a 8.2μF for the 5V input device, a 3.3μF for the 12V input devices and a 1.5μF for the 24V and 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2016/03/18
REV:0