MJWI20

®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
FEATURES
►Smallest Encapsulated 20W Converter
►Ultra-compact 1" X 1" Package
►Ultra-wide 4:1 Input Voltage Range
►Fully Regulated Output Voltage
►Excellent Efficiency up to 89%
►I/O Isolation 1500 VDC
►Operating Ambient Temp. Range -40℃ to +85℃
►No Min. Load Requirement
►Overload/Voltage and Short Circuit Protection
►Remote On/Off Control, Output Voltage Trim
►Shielded Metal Case with Insulated Baseplate
►UL/cUL/IEC/EN 60950-1 Safety Approval
PRODUCT OVERVIEW
The MINMAX MJWI20 series is a new generation of high performance dc-dc converter modules setting a new standard concerning power density. The
product offers fully 20W in a shielded metal package with dimensions of just 1.0"x1.0"x 0.4". All models provide ultra-wide 4:1 input voltage range and tight
output voltage regulation.
State-of the-art circuit topology provides a very high efficiency up to 89% which allows an operating temperature range of -40°C to +85°C. Further features
include remote On/Off, trimmable output voltage as well as overload protection and over-temperature protection.
Typical applications for these converters are battery operated equipment, instrumentation, distributed power architectures in communication and industrial
electronics and other space critical applications.
Model Selection Guide
Model
Number
MJWI20-24S033
MJWI20-24S05
MJWI20-24S12
MJWI20-24S15
MJWI20-24S24
MJWI20-24D12
MJWI20-24D15
MJWI20-48S033
MJWI20-48S05
MJWI20-48S12
MJWI20-48S15
MJWI20-48S24
MJWI20-48D12
MJWI20-48D15
Input
Voltage
(Range)
Output
Voltage
VDC
VDC
3.3
5
12
15
24
±12
±15
3.3
5
12
15
24
±12
±15
24
(9 ~ 36)
48
(18 ~ 75)
Output Current
Input Current
Max.
Min.
@Max. Load
@No Load
mA
4500
4000
1670
1340
835
±835
±670
4500
4000
1670
1340
835
±835
±670
mA
0
0
0
0
0
±60
±50
0
0
0
0
0
±60
±50
mA(typ.)
711
936
938
941
949
938
941
352
468
469
471
474
469
471
mA(typ.)
80
90
40
40
40
40
40
40
45
25
25
25
25
25
Reflected
Ripple
Current
Over
Voltage
Protection
Max. capacitive
Load
mA (typ.)
VDC
3.9
6.2
15
18
30
±15
±18
3.9
6.2
15
18
30
±15
±18
μF
10300
6800
1200
750
300
680#
380#
10300
6800
1200
750
300
680#
380#
50
30
Efficiency
(typ.)
@Max. Load
%
87
89
89
89
88
89
89
88
89
89
89
88
89
89
# For each output
Input Specifications
Parameter
Conditions / Model
24V Input Models
48V Input Models
24V Input Models
48V Input Models
Input Filter
Conducted EMI
Typ.
Max.
Unit
50
--100
--VDC
----9
----18
----30
ms
Nominal Vin and Constant Resistive Load
----30
ms
Internal LC Type
All Models
Internal LC Filter (for EN55022,Class A and FCC level A compliance see page 8)
E-mail:[email protected]
Tel:886-6-2923150
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Start Up Time
2015/10/15
Power Up
Remote On/Off
REV:18
Page 1 of 10
Min.
-0.7
-0.7
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
Remote On/Off Control
Parameter
Conditions
Min.
Converter On
Typ.
Max.
Unit
3.5V ~ 12V or Open Circuit
Converter Off
0V ~ 1.2V or Short Circuit
Control Input Current (on)
Vctrl = 5.0V
---
---
0.5
mA
Control Input Current (off)
Vctrl = 0V
---
---
-0.5
mA
mA
Control Common
Referenced to Negative Input
Standby Input Current
Supply Off & Nominal Vin
---
10
---
Conditions / Model
Min.
Typ.
Max.
Unit
---
---
±1.0
%Vnom.
Dual Output, Balanced Loads
---
---
±2.0
%
Single Output
---
---
±0.2
%
Dual Output
---
---
±0.5
%
3.3V & 5V
---
---
±0.5
%
12V,15V & 24V
---
---
±0.2
%
---
---
±1.0
%
---
---
±5.0
%
3.3V & 5V Models(3)
---
75
---
mV P-P
12V & 15V & Dual Models(3)
---
100
---
mV P-P
24V Models(3)
---
150
---
mV P-P
-----
300
±3
--±5
μsec
%
Output Specifications
Parameter
Output Voltage Setting Accuracy
Output Voltage Balance
Line Regulation
Vin=Min. to Max. @Full Load
Load Regulation
Io=0% to 100%
Single
Output
Dual Output
Load Cross Regulation (Dual Output)
Ripple & Noise
Asymmetrical Load 25%/100% Full Load
0-20 MHz Bandwidth
Transient Recovery Time
Transient Response Deviation
25% Load Step Change
Temperature Coefficient
Trim Up / Down Range (See Page 8)
---
---
±0.02
%/℃
% of Nominal Output Voltage
---
---
±10
%
Hiccup
---
150
---
%
Over Load Protection
Short Circuit Protection
Hiccup Mode 1.5 Hz typ., Automatic Recovery
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
60 Seconds
1 Second
1500
1800
-----
-----
VDC
VDC
Isolation Voltage Input/Output to case
60 Seconds
1000
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
---
1500
pF
---
330
---
KHz
Switching Frequency
MTBF(calculated)
MIL-HDBK-217F@25℃, Ground Benign
Safety Approvals
E-mail:[email protected]
2015/10/15
451,600
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report)
REV:18
Tel:886-6-2923150
Page 2 of 10
Hours
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
Environmental Specifications
Parameter
Conditions / Model
Operating Ambient Temperature Range
Natural Convection
Nominal Vin, Load 100% Inom.
(for Power Derating see relative Derating Curves)
Min.
Max.
without Heatsink
with Heatsink
MJWI20-48S033
+68
+74
MJWI20-24S033
+64
+71
+60
+67
MJWI20-XXS05, MJWI20-XXS12
MJWI20-XXS15, MJWI20-XXD12
-40
℃
MJWI20-XXD15
MJWI20-XXS24
Thermal Impedance
Unit
+55
+63
50LFM Convection without Heatsink
18.2
---
℃/W
50LFM Convection with Heatsink
15.3
---
℃/W
100LFM Convection without Heatsink
13.9
---
℃/W
100LFM Convection with Heatsink
8.8
---
℃/W
200LFM Convection without Heatsink
12.1
---
℃/W
6.8
---
℃/W
400LFM Convection without Heatsink
9.1
---
℃/W
400LFM Convection with Heatsink
200LFM Convection with Heatsink
4.6
---
℃/W
Case Temperature
---
+105
℃
Storage Temperature Range
-50
+125
℃
Humidity (non condensing)
---
95
% rel. H
260
℃
Cooling
Natural Convection
RFI
Six-Sided Shielded, Metal Case
Lead Temperature (1.5mm from case for 10Sec.)
E-mail:[email protected]
2015/10/15
REV:18
Tel:886-6-2923150
Page 3 of 10
---
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
Power Derating Curve
100
100
80
50LFM
Output Power (%)
Output Power (%)
80
100LFM
60
200LFM
400LFM
40
20
50LFM
100LFM
60
200LFM
400LFM
40
20
0
0
~
-40
0
20
40
60
80
~
100 110
-40
0
20
Ambient Temperature C
MJWI20-48S033 Derating Curve without Heatsink
Output Power (%)
Output Power (%)
80
50LFM
100LFM
60
200LFM
400LFM
40
100 110
50LFM
100LFM
60
200LFM
400LFM
40
20
20
0
0
~
-40
0
20
40
60
80
~
-40
100 110
0
20
40
60
80
100 110
Ambient Temperature C
Ambient Temperature C
MJWI20-24S033 Derating Curve without Heatsink
MJWI20-24S033 Derating Curve with Heatsink
100
100
80
50LFM
80
Output Power (%)
Output Power (%)
80
100
80
100LFM
60
200LFM
400LFM
40
50LFM
100LFM
60
200LFM
400LFM
40
20
20
0
0
~
-40
0
20
40
60
80
~
-40
100 110
0
20
40
60
80
100 110
Ambient Temperature C
Ambient Temperature C
MJWI20-XXS05, MJWI20-XXS12, MJWI20-XXS15, MJWI20-XXD12,
MJWI20-XXD15 Derating Curve without Heatsink
MJWI20-XXS05, MJWI20-XXS12, MJWI20-XXS15, MJWI20-XXD12,
MJWI20-XXD15 Derating Curve with Heatsink
100
100
80
80
50LFM
Output Power (%)
Output Power (%)
60
MJWI20-48S033 Derating Curve with Heatsink
100
100LFM
60
200LFM
400LFM
40
20
50LFM
100LFM
60
200LFM
400LFM
40
20
0
0
~
-40
0
20
40
60
80
100 110
Ambient Temperature C
MJWI20-XXS24 Derating Curve without Heatsink
E-mail:[email protected]
2015/10/15
40
Ambient Temperature C
REV:18
Tel:886-6-2923150
Page 4 of 10
~
-40
0
20
40
60
80
100 110
Ambient Temperature C
MJWI20-XXS24 Derating Curve with Heatsink
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
100
100
90
90
80
80
Efficiency(%)
Efficiency(%)
Efficiency Curve @25℃
70
60
50
24V
10
20
30
40
50
60
70
80
90
9V
24V
40
36V
30
60
50
9V
40
70
36V
30
100
10
20
30
% of Full Load
50
60
70
80
90
100
% of Full Load
MJWI20-24S033 Efficiency vs Load Current
MJWI20-24S05 Efficiency vs Load Current
100
100
90
90
80
80
Efficiency(%)
Efficiency(%)
40
70
60
70
60
50
9V
50
40
24V
40
9V
24V
36V
30
36V
30
10
20
30
40
50
60
70
80
90
100
10
20
30
% of Full Load
90
80
80
Efficiency(%)
Efficiency(%)
100
90
70
60
50
24V
40
50
60
70
80
90
9V
24V
36V
30
100
10
20
30
90
80
80
Efficiency(%)
Efficiency(%)
100
70
60
50
18V
48V
40
75V
30
50
60
70
80
90
100
% of Full Load
MJWI20-48S033 Efficiency vs Load Current
E-mail:[email protected]
2015/10/15
REV:18
50
60
70
80
90
100
MJWI20-24D15 Efficiency vs Load Current
90
40
40
% of Full Load
100
30
100
60
MJWI20-24D12 Efficiency vs Load Current
20
90
70
% of Full Load
10
80
40
36V
30
40
70
50
9V
30
60
MJWI20-24S15 Efficiency vs Load Current
100
20
50
% of Full Load
MJWI20-24S12 Efficiency vs Load Current
10
40
Tel:886-6-2923150
Page 5 of 10
70
60
50
18V
48V
40
75V
30
10
20
30
40
50
60
70
80
90
100
% of Full Load
MJWI20-48S05 Efficiency vs Load Current
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
100
100
90
90
80
80
Efficiency(%)
Efficiency(%)
Efficiency Curve @25℃
70
60
50
48V
10
20
30
40
50
60
70
80
90
18V
48V
40
75V
30
60
50
18V
40
70
75V
30
100
10
20
30
% of Full Load
90
80
80
Efficiency(%)
Efficiency(%)
100
90
70
60
50
18V
48V
40
75V
30
30
40
50
60
60
70
80
90
100
MJWI20-48S15 Efficiency vs Load Current
100
20
50
% of Full Load
MJWI20-48S12 Efficiency vs Load Current
10
40
70
80
90
100
% of Full Load
MJWI20-48D12 Efficiency vs Load Current
70
60
50
18V
48V
40
75V
30
10
20
30
40
50
60
70
80
90
100
% of Full Load
MJWI20-48D15 Efficiency vs Load Current
Notes
1
2
3
4
5
6
7
Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
Transient recovery time is measured to within 1% error band for a step change in output load of 75% to 100%.
Ripple & Noise measurement with a 1μF MLCC and a 10μF Tantalum Capatitor.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
The MJWI20 series can meet EN55022 Class A with parallel an external LC Filter to the input pins. Please refer to Test Configurations on the last page.
Specifications are subject to change without notice.
E-mail:[email protected]
2015/10/15
REV:18
Tel:886-6-2923150
Page 6 of 10
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
Package Specifications
Mechanical Dimensions
Pin Connections
2.54
[0.10]
25.4 [1.00]
10.16
[0.40]
10.16
[0.40]
4
Bottom View
1
2
6
1.00
[0.04]
20.3 [0.80]
5
25.4 [1.00]
3
6.0
10.16 0.5
[0.24] [0.40 0.02]
Pin
Single Output
Dual Output
1
+Vin
+Vin
2
-Vin
-Vin
3
+Vout
+Vout
4
Trim
Common
5
-Vout
-Vout
6
Remote On/Off
Remote On/Off
►All dimensions in mm
►Tolerance: X.X±0.25
(inches)
(X.XX±0.01)
X.XX±0.13 ( X.XXX±0.005)
5.08
[0.20]
7.62
[0.30]
►Pin
2.54
[0.10]
diameter  1.0 ±0.05 (0.04±0.002)
Physical Characteristics
Case Size
:
25.4x25.4x10.16mm (1.0x1.0x0.4 inches)
Case Material
:
Aluminium Alloy, Black Anodized Coating
Base Material
:
FR4 PCB (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Weight
:
15g
Heatsink (Option –HS)
Mechanical Dimensions
Heatsink Material: Aluminum
Finish: Anodic treatment (black)
16.3 [0.64]
Weight: 2g
17.46 Max.
[0.69] Max.
19.5 Max.
[0.77] Max.
31.0 [1.22] Max.
Heat-Sink
Thermal Pad
Clamp
Converter
E-mail:[email protected]
2015/10/15
REV:18
Tel:886-6-2923150
Page 7 of 10
►The advantages of adding a
heatsink are:
1. To improve heat dissipation and increase the
stability and reliability of the DC/DC converters at
high operating temperatures.
2. To increase operating temperature of the DC/DC
converter, please refer to Derating Curve.
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
External Filter meets Conducted EMI EN55022 class A ; FCC part 15 level A
C2
L1
+Vo
Vout
+Vin
+Vin
Model
Component
Value
MJWI20-24XXX
C1
3.3μF/50V 1210 X7R MLCC
C2(24S24 only)
220pF/2KV 1808 MLCC
L1
6.8μH
C1
2.2μF/100V 1210 X7R MLCC
C2(48S24 only)
220pF/2KV 1808 MLCC
L1
12μH
Load
C1
MJWI20-48XXX
-Vin
-Vin
-Vo
-Vout
External Output Trimming
Output can be externally trimmed by using the method shown below
Rd
Ru
3
4
5
2
4
1
6
2
6
Trim Down
Trim Up
MJWI20-XXS033 Trim Table
Trim down
1
2
Vout=
Vox0.99
Vox0.98
Rd=
72.61
32.55
5
MJWI20 Module
Bottom View
MJWI20 Module
Bottom View
1
3
3
Vox0.97
19.20
4
Vox0.96
12.52
5
Vox0.95
8.51
6
Vox0.94
5.84
7
Vox0.93
3.94
8
Vox0.92
2.51
9
Vox0.91
1.39
10
Vox0.90
0.50
%
Volts
KOhms
Trim up
1
Vout=
Vox1.01
Ru=
60.84
MJWI20-XXS05 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
138.88
2
Vox1.02
27.40
3
Vox1.03
16.25
4
Vox1.04
10.68
5
Vox1.05
7.34
6
Vox1.06
5.11
7
Vox1.07
3.51
8
Vox1.08
2.32
9
Vox1.09
1.39
10
Vox1.10
0.65
%
Volts
KOhms
2
Vox0.98
62.41
3
Vox0.97
36.92
4
Vox0.96
24.18
5
Vox0.95
16.53
6
Vox0.94
11.44
7
Vox0.93
7.79
8
Vox0.92
5.06
9
Vox0.91
2.94
10
Vox0.90
1.24
%
Volts
KOhms
Trim up
1
Vout=
Vox1.01
Ru=
106.87
MJWI20-XXS12 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
413.55
2
Vox1.02
47.76
3
Vox1.03
28.06
4
Vox1.04
18.21
5
Vox1.05
12.30
6
Vox1.06
8.36
7
Vox1.07
5.55
8
Vox1.08
3.44
9
Vox1.09
1.79
10
Vox1.10
0.48
%
Volts
KOhms
2
Vox0.98
184.55
3
Vox0.97
108.22
4
Vox0.96
70.05
5
Vox0.95
47.15
6
Vox0.94
31.88
7
Vox0.93
20.98
8
Vox0.92
12.80
9
Vox0.91
6.44
10
Vox0.90
1.35
%
Volts
KOhms
Trim up
1
Vout=
Vox1.01
Ru=
351.00
MJWI20-XXS15 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
530.73
2
Vox1.02
157.50
3
Vox1.03
93.00
4
Vox1.04
60.75
5
Vox1.05
41.40
6
Vox1.06
28.50
7
Vox1.07
19.29
8
Vox1.08
12.37
9
Vox1.09
7.00
10
Vox1.10
2.70
%
Volts
KOhms
2
Vox0.98
238.61
3
Vox0.97
141.24
4
Vox0.96
92.56
5
Vox0.95
63.35
6
Vox0.94
43.87
7
Vox0.93
29.96
8
Vox0.92
19.53
9
Vox0.91
11.41
10
Vox0.90
4.92
%
Volts
KOhms
Trim up
1
Vout=
Vox1.01
Ru=
422.77
MJWI20-XXS24 Trim Table
Trim down
1
Vout=
Vox0.99
Rd=
598.66
2
Vox1.02
189.89
3
Vox1.03
112.26
4
Vox1.04
73.44
5
Vox1.05
50.15
6
Vox1.06
34.63
7
Vox1.07
23.54
8
Vox1.08
15.22
9
Vox1.09
8.75
10
Vox1.10
3.58
%
Volts
KOhms
2
Vox0.98
267.78
3
Vox0.97
157.49
4
Vox0.96
102.34
5
Vox0.95
69.25
6
Vox0.94
47.19
7
Vox0.93
31.44
8
Vox0.92
19.62
9
Vox0.91
10.43
10
Vox0.90
3.08
%
Volts
KOhms
2
Vox1.02
218.02
3
Vox1.03
128.31
4
Vox1.04
83.46
5
Vox1.05
56.55
6
Vox1.06
38.61
7
Vox1.07
25.79
8
Vox1.08
16.18
9
Vox1.09
8.70
10
Vox1.10
2.72
%
Volts
KOhms
Trim up
Vout=
Ru=
1
Vox1.01
487.14
E-mail:[email protected]
2015/10/15
REV:18
Tel:886-6-2923150
Page 8 of 10
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
Order Code Table
Standard
With heatsink
MJWI20-24S033
MJWI20-24S033-HS
MJWI20-24S05
MJWI20-24S05-HS
MJWI20-24S12
MJWI20-24S12-HS
MJWI20-24S15
MJWI20-24S15-HS
MJWI20-24S24
MJWI20-24S24-HS
MJWI20-24D12
MJWI20-24D12-HS
MJWI20-24D15
MJWI20-24D15-HS
MJWI20-48S033
MJWI20-48S033-HS
MJWI20-48S05
MJWI20-48S05-HS
MJWI20-48S12
MJWI20-48S12-HS
MJWI20-48S15
MJWI20-48S15-HS
MJWI20-48S24
MJWI20-48S24-HS
MJWI20-48D12
MJWI20-48D12-HS
MJWI20-48D15
MJWI20-48D15-HS
E-mail:[email protected]
2015/10/15
REV:18
Tel:886-6-2923150
Page 9 of 10
®
MJWI20 SERIES
DC/DC CONVERTER 20W, Highest Power Density
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance. Capacitor Cin, offsets
possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
DC / DC
Converter
Current
Probe
Cin
+Out
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a 1μF ceramic capacitor and a 10μF tantalum capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz.
Position the load between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
+Out
Dual Output
DC / DC
Converter
Com.
-Vin
Copper Strip
Copper Strip
+Vin
Scope
Cout
Resistive
Load
Copper Strip
Cout
-Out
Scope
Copper Strip
Technical Notes
Remote On/Off
Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and off during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic
low is 0V to 1.2V. A logic high is 3.5V to 12V. The maximum sink current at the on/off terminal (Pin 6) during a logic low is -500μA. The maximum allowable
leakage current of a switch connected to the on/off terminal (Pin 6) at logic high (3.5V to 12V) is 10mA.
Overload Protection
To provide hiccup mode protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure overload for an
unlimited duration.
Overvoltage Protection
The output overvoltage clamp consists of control circuitry, which is independent of the primary regulation loop, that monitors the voltage on the output terminals.
The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of output
overvoltage. The OVP level can be found in the output data.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module.
In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0
Ω at 100 KHz) capacitor of a 10μF for the 24V and 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 4.7μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Maximum Capacitive Load
The MJWI20 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 105℃. The derating curves are determined
from measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2015/10/15
REV:18