50(W) x 28(H) x 95(L) mm DPS-40AP-10 A Input Voltage range 90~264Vac auto range Frequency 47~63Hz Efficiency The average efficiency at 25%, 50%, 75% and 100% load ≥ 87% Input Current Output 90~132Vac /12V/3.33A load ≤ 1.2A 180~264Vac / 12V/3.33A load ≤ 0.6A 12V 0A to 3.33A Over-current Auto recovery Over-temperature Latch Short Auto recovery Over-voltage Auto recovery Operating temp. 0 to 50°C Full load ,60°C 80% load, 70°C 60% load Storage temp. -20 to 70℃ Operating humidity 10% - 90% Storage humidity 10% - 95% Protection Environment FEATURES • Total power 40W • 90-264Vac auto range input • High reliability: >100,000 hours @ full load and normal input (25 ℃) • Protection: Short / Over-current / Over-voltage / Over-temperature • CCC: 5000 meter • Bulk Cap: JP Type • Safety: UL/cUL, TUV, CB by Demko ,CCC • EMI: CLASS B DPS-40AP-10 A Electrical Safety UL/cUL, TUV, CB,CCC,CE, BSMI refer to EN 60950-1 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC EMI: refer to CISPR 22 ,FCC ,VCCI:CLASS B Air Discharge: ± 8KV min Safety Standards/Directives ESD(IEC61000-4-2) Contact Discharge: ±4KV min. EMC EFT(IEC61000- 4-4) +/- 2KV Common Mode:+/- 4KV Surge(IEC61000-4-5) Isolation Input to Output 3.0KVac Different Mode:+/- 2KV ▓Power de-rating curve