Features LED DRIVER ● ● ● ● ● ● Universal AC Input Constant Voltage / Constant Current Operation CE and UL Certified Class 1 LED Driver Active Power Factor Correction IP67 Design for Indoor and Outdoor Use Cooling by Free Air Convection LIGHTLINE AC/DC-Converter with 5 year Warranty Selection Guide Part Number CV Mode Constant Voltage Current Range (V) (A) CC Mode DC Voltage Range Constant Current (V) (A) Efficiency (230VAC) (%) RACD100-12 12 0-8.3 9-12 8.3 88 RACD100-24 24 0-4.2 14-24 4.2 90 RACD100-36 36 0-2.8 26-36 2.8 90 RACD100-48 48 0-2.1 34-48 2.1 91 100 Watt Single Output Specifications Input Voltage Range Input Frequency Range Power Factor 90-305 VAC or 127-430VDC 47-63Hz. Full Load, 115VAC >0.98 Full Load, 230VAC >0.95 Full Load, 277VAC >0.94 THD Full Load, 115VAC 8% max. AC Current 115VAC 0.7A max. 230VAC 1.4A max. Input/Output Isolation 3.75kVAC Input/Case Isolation 1.8kVAC Output/Case Isolation 0.5kVAC Leakage Current 240VAC <0.75mA Voltage Tolerance -1% to 5% Set up Time 115VAC 1.5s (@ Full Load) 230VAC / 277VAC 0.7s Ripple & Noise 48V Version 200mV max. others 150mV max. Over Current Protection 95%-105% rated current Auto-Recovery Short Circuit Protection Hiccup Mode Over Voltage Protection 12V 15V typ. Latch Mode 24V 31V typ. (Power off to recover) 36V 45V typ. 48V 58V typ. Over Temperature Protection Tcase 95°C ±10°C Operation Temperature (Refer to Output Load Derating Curve) -30°C to +70°C Operation Humidity 20%-90% RH Non-Condensing Storage Temperature -40°C to +80°C Storage Humidity 10%-90% RH Vibration 2G 10min/1Cycle, Period for 60 min 10-500Hz IP Rating IP67 Safety Standards UL/cUL LED Lighting Safety (E340696) UL8750 CE LVD Directive, Safety EN61347-2-13 EMC Standards EMC Compatibility EN55015 FCC, Part 15 Harmonic Current EN61000-3-2 Class C (≥75% load) EN61000-3-3 EMC Immunity EN61000-4-2, 3, 4, 5, 6, 11 Dimension 222*68*39mm Weight 940g MTBF using MIL-HDBK-217F (25°C) 250 x 10³ hours Design Lifetime 70 x 10³ hours The use of a circuit breaker with C-characteristic is recommended. L-46 REV: 2/2013 RoHS 2011/65/EU 6/6 E340696 UL 8750 Certified EN 61347 Certified RACD100 www.recom-electronic.com RACD100 Series LIGHTLINE AC/DC-Converter Derating Curve Load Load 100% 100% 80% 80% 60% 60% 40% 40% 20% 20% -30 -10 10 30 50 70 55 Ta=25°C 90 100 130 180 220 240 300 Input Voltage (VAC)60Hz Ambient Temperature (°C) Characteristics Constant Voltage / Constant Current Curve RACD100-24 RACD100-12 CV Vout 12 (nom) CV Vout (nom) 24 CC CV Vout (nom) 36 CC Vout (min) 14 8.3 Iout 0 CV Vout (nom) 48 CC Vout (min) 26 4.2 Iout 0 RACD100-48 0 CC Vout (min) 34 2.8 Iout 2.1 Iout 0 Package Style and Pinning 3rd angle projection 222.0 11.4 7.0 300±20 AC/L (Brown) AC/N (Blue) Earth (Green/Yellow) 10±3 199.2 8.9 34.2 8.9 34.0 99.6 Tc 68.0 300±20 16AWG +V(Red) -V(Black) 14AWG for RACD100-12 35±5 35±5 10±3 39.0 www.recom-international.com REV: 2/2013 L-47 RACD100 Vout (min) 9 RACD100-36