Ku-Band Ku-Band 4900 Series Mini-BUCs Compact and Lightweight Designed and built with VSAT stabilized antenna platforms and other similar satcom-on-the-move customer applications in mind. Low Cost, High Performance Designed for operation in high ambient temperature environments, with superior phase noise performance. Guaranteed specified minimum P1dB power. Comprehensive M&C Functionality Accessible anytime, anywhere via Internet or mobile phone. Integrate with SNMP to NMS. Enables effective operational management and minimizes network outage. Allows change of IP address without serial cable. Quad LO, serial and LAN interface. Multi-Band Operation Select from multiple, factory-set frequency bands within Ku-band. Internal Self-Resetting Protection Protects against high temperatures, open/short output conditions. 4900 Series 8 and 16 watt Ku-band BUCs for maritime, VSAT, SOTM and other satellite uplink applications OPTIONS •Multi-band BUC: select from multiple factory-set frequency bands within Ku-band •1:1 redundant switching - BUC is configured for 1:1 systems as standard. System hardware is sold separately. •Auto-sensing, high stability external 10 MHz OCXO reference Global Applications Meets Electromagnetic Compatibility Directive 2004/108/EC to satisfy worldwide requirements and is CE-marked. Worldwide Support Backed by over 35 years of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than 20 regional factory service centers. 811 Hansen Way, PO Box 51625 Palo Alto, CA 94303 USA tel: +1 (650) 846-3803 fax: +1 (650) 424-1744 e-mail:[email protected] website:www.cpii.com/satcom Ku-Band Specifications 8 and 16 W Mini-BUCs Power Rating 8W 16 W Platform Model Number RF Output Frequency Range (GHz) Input Frequency Range (MHz) LO Frequency (MHz) DC Powered 4908(L)-W/S 4908(L)-W/E 4916(L)-W/S 4916(L)-W/E 14.00 to 14.50 13.75 to 14.50 14.00 to 14.50 13.75 to 14.50 950 to 1450 950 to 1700 950 to 1450 950 to 1700 13050 13050 / 12800, selectable 13050 13050 / 12800, selectable +41.5 dBm min. +41.0 dBm min. IF Input Power @ 1 dB, GCP, CW and Max. Gain -31 dBm nom. RF Output Power @ 1 dB, GCP, CW +39 dBm min. Gain at 0 dB Attenuation (max. gain) 70 dB nom. Gain Flatness Over Any 40 MHz Band ±1.0 dB max. Gain Flatness Over Full Band ±2.0 dB max. Gain Stability Over Any 50°C range ±1.5 dB max. Gain Stability Over Operating Temperature Range ±2.0 dB max. when frequency set; ±3.0 dB max. when frequency not set Reference Frequency (external) 10 MHz Reference Frequency Input (external) Multiplexed via IFL on N-type transmit IF input Reference Frequency Level -10 to +5 dBm Frequency Conversion Spectrum non-inverting IF Input Impedance and Connector 50 Ω, N-type IF Input VSWR 1.8:1 max. Transmit Attenuator Steps 0 dB to 20 dB in 0.25 dB steps Output Power Meter Range/Accuracy 15 dB/±1.0 dB max. Output Power Meter Modes CW and burst (>100 uS) with adjustable threshold RF Output IMD Ratio -25 dBc max. with 2 CW carriers each at 6 dB OBO Spurious/Harmonic Output @ 3dB OBO -50 dBc max. EN 301-428/EN 301-430 Maximum Phase Noise (SSB) of Reference Frequency -65 dBc dBc/Hz at 100 Hz; -75 dBc/Hz at 1 kHz; -85 dBc/Hz at 10 kHz; -95 dBc/Hz at 100 kHz 2 nsecpp max. linear (over any 10 MHz); 0.00025 nsec/MHz2pp max, parabolic (over any 80 MHz); 1 nspp max. ripple (over full band) AM/PM Conversion Power Supply Voltage Power Supply Minimum Turn-On Voltage Power Supply Consumption 2.00/dB max. at 2 dB OBO 18 to 60 VDC via IF I/P and ext DC connector 28 to 60 VDC via IF I/P and 18 to 60 VDC via ext DC conn. +20 VDC +29 VDC via IFL and 20 VDC via ext. conn. 90 W typ, 100 W max. 125 W typ, 130 W max. Operating/Storage Temp. Range -40 to +550C/-40 to +700C Relative Humidity 100% condensing Weatherproofing Connections Volume (for w/g output BUCs) Sealed to 34 kPa IF Input: N-Type Female; RF Output: WR75 PBR120 flange waveguide, 4 mm threaded holes; DC: MS 62IN 12E 8-2P with dust cap; M&C Serial Interface: 62IN-57A-12-14S(219) with dust cap; LAN connection, see page 3 247 x 151 x 85 mm (9.8 x 5.9 x 3.5”) without brackets Weight 2.4 kg (5.3 lbs) Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 373, ISSUE 5 dated DEC 2015 Page 2 of 3 EN 301-428/EN 301-430 -135 dBc dBc/Hz at 100 Hz; -145 dBc/Hz at 1 kHz; -155 dBc/Hz at 10 kHz; -155 dBc/Hz at 100 kHz Phase Noise (SSB) of BUC With Reference Frequency Defined Above Group Delay -50 dBc max. Ku-Band Configuration Guide 8 and 16 W Mini-BUC Configure your 4900 Series Ku-Band Mini-BUC Configuring your BUC is easy. For this product, most of the configuration is predetermined. After deciding the required output level, all that is left is to indicate whether LAN is required, which frequency range is needed, and whether the internal reference option is required. Instructions follow: Box 1: BUC Power Level - Enter 4908 for 8 watt BUC - Enter 4916 for 16 watt BUC Box 2: LAN Option placeholder - Enter “L” for BUCs with LAN option selected - LEAVE BLANK if the LAN option is not selected Box 4: Frequency range (within Ku-band) - Enter “S” for 14.00 to 14.50 GHz - Enter “E” for 13.75 to 14.50 GHz Box 8: Internal reference -Enter “R” only if internal reference option is selected -LEAVE BLANK if internal reference option is not selected _ 1 2 W 3 / 4 _ DC / 5 EX _ CE _ 6 7 8 Examples: 4908L-W/S-AC/EX-CE-R indicates an 8 watt BUC with a frequency range of 14.0 -14.5 GHz, including LAN and internal reference. 4916-W/E-AC/EX-CE indicates a 16 watt BUC with a frequency range of 13.75 to 14.5 GHz, without LAN and no internal reference. Notes: Box 3 indicates a waveguide RF output connection. Box 5 indicates that this product is DC powered. Box 6 indicates that power is fed via an external connector. Box 7 indicates that this product is CE marked. Quality Management System - ISO 9001:2008 For more detailed information, please refer to the corresponding CPI technical description if one has been published, or contact CPI. Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 373, ISSUE 5 dated DEC 2015, page 3 of 3