6900 Series BUC

is now part of....
Ku-Band 6900 series BLOCK UP CONVERTER
ä FEATURES AT A GLANCE
■ Ideally suited to rapid deploy or
offshore applications
■ AC or DC power via separate
connector for 25 W BUCs
■ Separate AC power supplies
available for DC powered BUCs
■ 48 V DC power via IFL and
external connector for
8/16 W LBUCs
■ Available in single thread and
1+1 redundant configurations
The CODAN™ Ku-Band 6900
series BUCs are purpose-built
for satcom-on-the-move
customers, while also offering
benefits for fixed site and
offshore applications.
Rugged & Reliable
■ Design MTBF exceeds 100,000 hours
■ IP67 rating that provides protection from water or dust storms
■ Sealed to 34 kPA (5 Psi)
Best RF Power Efficiency
■ 8–25 W of power for under 7 kg/15 lbs (LBUCs)
■ 25 W of RF power for <250 W of consumption AC or DC powered LBUC
■ 25 W of RF power for <375 W of consumption AC powered MBUC
Specifically Designed
■
■
■
■
■
■
Military applications
Broadcast applications
Size limited applications
Highly mobile ground systems
Remote area, install-and-forget applications
Harsh environment operation
Guaranteed Specifications
Guaranteed operation to specifications throughout the environmental
operating range:
■ Temperature (–40°C to +55°C)
■ Humidity (100%)
Most Comprehensive Monitor & Control
■ RS232, RS422/485
■ FSK and TCP/IP via FSK
■ Dry-contact closure
■ RF Power Meter
■ Optional Ethernet with 7550 LAN Interface
A large choice of management protocols are also built into the BUC.
Configuration Options
■ Standalone
■ Redundant 1+1 with Ethernet M&C
■ Optional AC Power Supplies
Best Lead Times
Ku-Band BUCs
■ Typical availability under 2 weeks
■ Ability to rapidly ramp up for larger requirements
Best Support
■ 24x7 Customer Support line
■ Worldwide Technical Support line
12-20190-EN Issue 18 2/2012
codansatcom.cpii.com
Ku-Band 6900 series BLOCK UP CONVERTER
Specifications
Power Rating
Platform
Model numbers
RF output connector
RF output VSWR
RF output frequency range
Input frequency range
LO frequency
IF input power @ 1 dB GCP, CW and max gain
8W
DC powered LBUC
6908-W/E-48/EX-CE-NI
16 W
25 W
DC powered LBUC
6916-W/S-48/EX-NI
WR75, PBR120 flange with 4.2 mm through holes
AC powered MBUC
6916-W/E-48/EX-CE-NI
6916-W/S-AC/EX-CE
6916-W/E-AC/EX-CE
WR75, PBR120 flange with 4.2 mm through holes
1.8:1 max
1.8:1 max
AC or DC powered LBUC
AC powered MBUC
6925-W/S-48/EX
6925-W/S-AC/EX-LB
6925-W/S-AC/EX-CE
6925-W/E-AC/EX
WR75, PBR120 flange with 4.2 mm through holes
1.5:1 max
1.5:1 max
Ext Band
13750 to 14500 MHz
Std Band
14000 to 14500 MHz
Ext Band
13750 to 14500 MHz
Std Band
14000 to 14500 MHz
Ext Band
13750 to 14500 MHz
Std Band
14000 to 14500 MHz
Ext Band
13750 to 14500 MHz
950 to 1700 MHz
950 to 1450 MHz
950 to 1700 MHz
950 to 1450 MHz
950 to 1700 MHz
950 to 1450 MHz
950 to 1700 MHz
12800 MHz
13050 MHz
12800 MHz
–31 dBm nominal
–31 dBm nominal
15450 MHz
15450 MHz
–31 dBm nominal
–31 dBm nominal
RF output power @ 1 dB GCP, CW
+39.0 dBm min
Gain @ 0 dB attenuation (max gain)
70 dB nominal
Gain flatness over any 40 MHz band
±1.50 dB max
±1.50 dB max
±0.75 dB max
Gain flatness over full band
±2.50 dB max
±2.50 dB max
±2.0 dB max
±2.0 dB max
Gain stability over any 50°C temperature range
±1.50 dB max
±1.50 dB max
±1.0 dB max
±1.0 dB max
Gain stability over entire temperature range
when frequency set
±2.0 dB max
±2.0 dB max
±2.0 dB max
Gain stability over entire temperature range
when frequency not set
±3.0 dB max
±3.0 dB max
±3.0 dB max
10 MHz
10 MHz
10 MHz
Multiplexed on N-type transmit IF input
Multiplexed on N-type transmit IF input
Multiplexed on N-type transmit IF input
Reference frequency (External)
Reference frequency input (External)
Reference frequency level
Reference frequency connector
Frequency conversion
Output power meter range
+42.0 dBm min
+41.5 dBm min
+41.7 dBm min
+41.0 dBm min
+43.4 dBm min
73 dB nominal
+43.0 dBm min
74 dB nominal
±1.50 dB max
±0.75 dB max
–10 to +5 dBm
–10 to +5 dBm
–10 to +5 dBm
Via N-type transmit IF input
Via N-type transmit IF input
Via N-type transmit IF input
Non-inverting
Non-inverting
Spectrum inverting
Spectrum inverting
15 dB
15 dB
10 dB
15 dB
Output power meter absolute accuracy when
compensation frequency set
±1.0 dB max
±1.0 dB max
±1.0 dB max
Output power meter absolute accuracy when
compensation frequency not set
±2.0 dB max
±2.0 dB max
±2.0 dB max
Output power meter relative accuracy when
compensation frequency set
±0.5 dB max
±0.5 dB max
±0.5 dB max
Output power meter relative accuracy when
compensation frequency not set
Power meter modes
Power supply voltage
Power supply minimum turn-on voltage @ 48 V
Power supply consumption
Volume (for waveguide output BUCs)
Weight
±1.0 dB max
±1.0 dB max
±1.0 dB max
CW and burst (>100 uS) with adjustable threshold
CW and burst (>100 uS) with adjustable threshold
CW and burst (>100 uS) with adjustable threshold
+34 to +60 V DC via transmit IF input and
via external DC connector
+34 to +60 V DC via transmit IF input and
via external DC connector
94 to 275 V AC via Amphenol T 3110 000
AC: 94 to 275 V AC via
Amphenol T 3110 000
DC: 34 V to 60 V DC
(+ve or –ve earth) via
external DC connector
94 to 275 V AC via Amphenol T 3110 000
+41 V
+41 V
N/A
AC: N/A,
DC: 41 V (+ve or –ve earth)
N/A
130 W max
150 W max
300 W max
250 W max
375 W max
360 mm L x 182 mm W x 137 mm H
14.2” L x 7.2” W x 5.4” H
360 mm L x 182 mm W x 137 mm H
14.2” L x 7.2” W x 5.4” H
522 mm L x 182 mm W x 204 mm H
20.6” L x 7.2” W x 8.0” H
335 mm L x 182 mm W
x 145 mm H
13.2” L x 7.2” W x 5.7” H
522 mm L x 182 mm W x 204 mm H
20.6” L x 7.2” W x 8.0” H
6 kg (13 lbs)
6 kg (13 lbs)
12 kg (26.5 lbs)
7 kg (15.5 lbs)
12 kg (26.5 lbs)
Values noted are typical at 25°C. Equipment descriptions and specifications are subject to change without notice or obligation.
codansatcom.cpii.com
Ku-Band 6900 series BLOCK UP CONVERTER
Common Specifications
IF input connector
N-type
IF input impedance
50 Ω
IF input VSWR
1.7:1 max
Transmit attenuator steps
0 dB to 12 dB in 4 dB steps
RF output IMD ratio with 2 CW carriers each
@ 6 dB OPBO
–25 dBc max
Spurious/harmonic output @ 3 dB OPBO
–50 dBc max (CE Versions: EN 301-428/EN 301-430)
Harmonic output @ 3 dB OPBO
–60 dBc max
Maximum phase noise (SSB) of reference frequency:
100 Hz
1 kHz
10 kHz
100 kHz
–135 dBc/Hz
–145 dBc/Hz
–155 dBc/Hz
–155 dBc/Hz
Phase noise (SSB) of BUC with reference frequency
defined above:
100 Hz
1 kHz
10 kHz
100 kHz
–63 dBc/Hz
–73 dBc/Hz
–83 dBc/Hz
–93 dBc/Hz
Group delay
Linear (over any 10 MHz band)
Parabolic (over any 80 MHz band)
Ripple (over full band)
2 nsecpp max
0.00025 nsec/MHz2pp max
1 nsecpp max
AM/PM conversion
2.0°/dB max @ 2 dB OPBO
Monitor & Control
Digital data format RS232
Digital data format RS485
Digital connector
FSK data format
FSK data transmitter frequency
FSK data transmitter deviation
FSK data transmitter sense
FSK output level
FSK start tone time
FSK data receiver nominal frequency
FSK data receiver locking range
FSK data receiver input sensitivity
9600 bps, 8 bits, no parity, 1 stop bit, ASCII protocol
User selectable protocols
MIL-C-26482 12-14S socket
User selectable protocols
650 kHz ±1%
±60 kHz ±1%
+60 kHz=mark; –60 kHz=space
–8 dB nominal
10 ms min
650 kHz
±30 kHz
–15 dBm min
Operating temperature range
–40 to +55°C
Non-operating/storage temperature range
–40 to +70°C
Relative humidity
100%
Weatherproofing
Sealed to 34 kPa
Americas
(Head Office)
Europe, Middle-East Asia-Pacific
& Africa
CPI
Satcom Products
Palo Alto, CA USA
CPI International Inc.
Cham, Switzerland
T: +41 (41) 560 7550
F: +41 (41) 560 755
CPI Asia Inc.
Singapore
T: +65 6225 0011
F: +65 9620 5200
CPI Europe Limited
Surrey, England
T: +44 (1932) 256 930
F: +44 (1932) 241 271
www.cpii.com/satcomsales
T: +1 (650) 846-3803
F: +1 (650) 424-1744
12-20190-EN Issue 18 2/2012
[email protected]