Download this Data Sheet

Model # BXHF1089
High Frequency Microwave Amplifier
Frequency Range: 6 to 12 GHz
Features
• High Output Power: +19 dBm Typical
• Laser Welded Housing for Ultimate Environmental Protection
• Internal Voltage Regulator
• RoHS Compliant Option: Model BXHF1089LF
• EAR99
Model BXHF1089 is a high frequency amplifier covering 6 to 12 GHz. This design utilizes a laser sealed
housing for superior environmental protection. This standard design may also be ordered in a screened MILSTD-883 version (Model #SXHF1089.) All specification ratings are based on measurements in a 50 Ω (ohm)
system with a DC supply voltage tolerance of +/- 2%.
Technical Specifications
Maximum Ratings
Parameter
Unit
Typical
Min/Max
Frequency Range
GHz
6 to12
6 to 12
Gain
dB
20
Noise Figure
dB
Output Power @ 1 dB
Compression
Maximum (No Damage) Ratings
Storage Temperature
-55°C to +85°C
19 (Min.)
Operating Temperature
-40°C to +85°C
7.0
8.0 (Max.)
DC Voltage @ 25°C
+18 volts
dBm
19
18 (Min.)
Input Drive @ 25°C (CW)
+13 dBm
Output 3rd Order Intercept
dBm
30
-
Output 2nd Order Intercept
dBm
39
-
Reverse Isolation
dB
25
-
Input VSWR
---
1.5:1
2.0:1 (Max.)
Output VSWR
---
1.5:1
2.0:1 (Max.)
Supply Voltage
volts
+12 to +15
+12 to +15
Supply Current
mA
125
140 (Max.)
* Typical values are measured at 25°C,
but not guaranteed.
Mechanical & Electrical
Parameter
Specification
Specification Temperatures (Min/Max)
-20°C to +70°C
Housing Size
1.500” L x 1.060” W x 0.300” H
Housing Drawing
HF2 Package
RF Connectors
SMA Female Replaceable Connectors
Rev Date: 9/22/2015
© API Technologies Corp. Proprietary Information
Page # 1
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]
Model # BXHF1089
Typical Performance Graphs
Rev Date: 9/22/2015
© API Technologies Corp. Proprietary Information
Page # 2
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]
Model # BXHF1089
Instructions
Grounding Instructions
Care should be taken to effectively ground each unit.
Revisions
API reserves the right to make revisions to both product and/or the information contained within their
datasheets without advanced notice.
Min./Max. Values
Specifications are guaranteed when tested in a 50 Ω (ohm) system.
Typical performance graphs and values are measured at 25°C, but not guaranteed.
Outline Drawing
(outlines for reference only)
Rev Date: 9/22/2015
© API Technologies Corp. Proprietary Information
Page # 3
|
www.apitech.com
|
micro.apitech.com
|
+1.888.553.7531
|
[email protected]