54-160.1 Hygienic Thermatel

Hygienic Thermatel®
Thermal Dispersion
Flow & Level Switch
D E S C R I P T I O N
Designed for use specifically in the clean or hygienic
process industry, the Thermatel® TD2 is an outstanding
flow/level switch where easy external wipe-down and a
sensor free of cracks and crevices are required. The TD2
Thermal Dispersion Flow/Level switch provides
continuous diagnostics, temperature compensation
narrow hysteresis, and fast response time for superior
performance.
The TD2 switch uses either AC or DC input power, provides a DPDT relay output with a visual LED indication
of status through the glass window in the cover. Other
features include ability to electronically measure the set
point, a mA output signal for trending and diagnostics
and time delay.
See Magnetrol® Brochure 54-110 for additional information and complete specifications.
Model TD2
with hygienic
stainless steel enclosure
& spherical tip probe
T E C H N O L O G Y
F E A T U R E S
• Temperature compensated to provide repeatable
alarm under varying process temperatures
• Continuous diagnostics detect sensor fault
• A non-linear mA output signal can be used for
trending, diagnostics and repeatable flow/level
indication
• Detects minimum flow or presence/absence of flow
• Simple/fast calibration
• Excellent low flow sensitivity
• Process temperatures from -100° to +400° F
(-73° to +204° C)
• Fast response time
• 316 stainless steel probe with 32 Ra finish
The THERMATEL TD2 switch utilizes MAGNETROL
proven thermal dispersion technology. The sensor consists of two RTD elements. One is the reference and the
second is heated to a temperature above the process
temperature. The electronics detect the temperature difference between the two elements. The temperature difference is greatest in air, then decreases when cooling
occurs due to a change in media. An increase in the flow
rate further decreases the temperature difference.
The set point is adjusted for the switch to alarm at the
desired temperature difference. Once the set point is
reached, the relay will change state.
A P P L I C A T I O N S
PUMP PROTECTION
Discharge Flow ·
Installed on the suction or discharge of a pump, a
THERMATEL switch provides rapid indication of a low flow
or no flow condition to prevent pump damage. No moving
parts, excellent low flow sensitivity, and low hysteresis
between alarm and reset points are all important features in
this application. Enhanced temperature compensation minimizes set point drift due to varying process temperatures.
ADDITIONAL APPLICATIONS:
Flow Switch
• Water for Injection
• CIP Systems
• CO2 Flow
Level Switch
• High Viscosity
M O D E L
T D 2
Hygienic Centrifugal Pump Protection
N U M B E R
E L E C T R O N I C S
POWER
7
8
AC power
DC power
RELAY OUTPUT
D
H
DPDT 8 amp relay
DPDT 1 amp hermetically sealed relay
GLASS WINDOW IN ENCLOSURE
0
1
None
Window provided
LOCATION
0
Integral
ENCLOSURE TYPE/CONDUIT CONNECTION
4
5
T
2
D
2
0
0
7
304 stainless steel – 1⁄2" NPT (single entry)
304 stainless steel – M20 (dual entry)
DIMENSIONAL
Model
TD2
with
SPECIFICATIONS
Hygienic
Housing
&
INCHES
(MM)
Tri-Clamp® Connection
5.24
(133)
5.75
(146)
1.05 (26)
Typical
Insertion
length
∅ .875
(23) Dia.
M O D E L
N U M B E R
S T A N D A R D
P R O B E
MODEL
TE
TM
Probe length in inches
Probe length in centimeters
TIP STYLE
A
B
Spherical tip
Spherical tip – with 6" heat extension
max. +250° F (+121° C)/max. 600 psi (41 bar)
max. +400° F (+204° C)/max. 600 psi (41 bar)
MATERIAL OF CONSTRUCTION
A
316/316L stainless steel
HYGIENIC CONNECTIONS
3T
4T
VV
11⁄2"
2"
DN65
Tri-Clamp®
Tri-Clamp
Varivent®
Contact MAGNETROL for other hygienic fittings including Neumo, G1A, and DIN 11.851.
INSERTION LENGTH
003
006
A
Minimum Tri-Clamp® length is 2.8" and Varivent® is 2.3"
in 1" increments to length of 130 inches
Minimum Tri-Clamp® length is 5.6 cm and Varivent® is 5.8 cm
Extended lengths in 10 mm increments to length 3300 mm
Examples: 3300 mm = code 330, 80 mm = code 008
0
3
Q U A L I T Y
The quality assurance system in place at
MAGNETROL guarantees the highest
level of quality throughout the company.
MAGNETROL is committed to providing full
customer satisfaction both in quality products
and quality service.
The MAGNETROL quality assurance system
is registered to ISO 9001 affirming its commitment to known international quality
standards providing the strongest assurance
of product/service quality available.
W A R R A N T Y
All MAGNETROL electronic level and flow
controls are warranted free of defects in
materials or workmanship for one full year
from the date of original factory shipment.
If returned within the warranty period; and,
upon factory inspection of the control, the
cause of the claim is determined to be covered
under the warranty; then, MAGNETROL
will repair or replace the control at no cost
to the purchaser (or owner) other than
transportation.
MAGNETROL shall not be liable for misapplication, labor claims, direct or consequential
damage or expense arising from the installation or use of equipment. There are no
other warranties expressed or implied,
except special written warranties covering
some MAGNETROL products.
For additional information, see Instruction Manual 54-610.
705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489
[email protected] • www.magnetrol.com
Copyright © 2016 Magnetrol International, Incorporated. All rights reserved. Printed in the USA.
Performance specifications are effective with date of issue and are subject to change without notice.
Magnetrol, Magnetrol logotype and Thermatel are registered trademarks of Magnetrol International, Incorporated.
Hastelloy® is a registered trademark of Haynes International, Inc.
Monel® and Inconel® are registered trademarks of Special Metals Corporation
Tri-Clamp® is a registered trademark of Ladish Co.
Varivent® is a registered trademark of Tuchenhagen GmbH LTD
BULLETIN: 54-160.1
EFFECTIVE: June 2016
SUPERSEDES: November 2007