MAGNETROL RPA

T H E R M A T E L®
T H E R M A L
D I S P E R S I O N
M
The Total Spectrum of Solutions
Magnetrol products employ many technologies to meet the challenges of level
and flow control. Thermatel switches and
transmitters utilize the principles of thermal
dispersion for accurate and reliable level,
flow, and interface control.
MAGNETROL
THERMAL DISPERSION PRODUCTS
M
agnetrol International
—a world leader in level
and flow control technology—
designs, manufactures, markets,
and services level and flow
instrumentation worldwide.
Magnetrol product groups are
based upon these technologies:
• Air Sonar
• Buoyancy
C
O
N
T
E
N
T
S
Thermal Dispersion Technology
• Contact Ultrasound
• Guided Wave Radar
• An Introduction to Thermatel
4
• Pulse Burst Radar
• RF Capacitance
Thermatel Thermal Dispersion Products:
• Thermal Dispersion
• Vibration
• Visual Indicators
The industries we serve include:
• Petroleum Production
• Petroleum Refining
• Power
• TA2 Mass Flow Transmitters
6
• TD1 & TD2 Flow/Level/Interface Switches
8
• TG1 Level/Flow/Interface Switch
9
• Thermatel Sensors
10
• Thermatel 052-7201 Switch
11
• Thermatel RPA Hot Tap Assembly
11
• Petrochemical
• Chemical
• Water & Wastewater
• Pulp & Paper
• Food & Beverage
• Pharmaceutical
3
An Introduction To Thermatel Technology & Products
T
hermatel products utilize thermal dispersion technology for unsurpassed accuracy and reliability in
monitoring gas flow, liquid flow, liquid level, and interface. A market-proven technology, thermal dispersion has
been in use by process industries for measurement and
control purposes since the early 1960s.
Product Scope
The Thermatel product line has been structured to
provide customers with a complete range of options in
thermal dispersion technology. Each Thermatel product is
engineered and manufactured to provide the highest reliability in even the most demanding process environments.
Thermatel products range from single-point switches
to the powerful TA2 Thermal Mass Flow Transmitter.
The TA2 powerful microprocessor-based electronics make
these units the premier thermal dispersion mass flow
meters in the industry. They are easy to set up, configure,
and provide high levels of accuracy, repeatability,
and diagnostics.
High Temperature Differential
©
©© ©
©
©
© ©
Low Temperature Differential
Thermatel switches employ twin RTD sensors to sense
process change in level and flow applications. One sensor
measures the surrounding process temperature to provide
a reference. The second sensor is self-heated to establish
a temperature differential above the reference temperature.
In level applications, the cooling effect of contacting media
reduces the temperature difference between the RTDs. In
flow applications, an increase in flow rate further decreases
the temperature difference. In each instance, the decrease
in temperature difference triggers a relay action.
4
Applications Range
Thermatel products are in
service worldwide in many
of the most demanding
applications. As a flow
switch Thermatel is used for
gas and liquid applications
for both flow and no/low
flow detection. Typical
applications involve pump
protection, cooling air/water,
relief valve monitoring,
exhaust flows and lubrication systems. Thermatel
products provide outstanding low flow sensitivity with
high rangeability.
Insertion probe designs for
Thermatel switches use two
basic RTD configurations.
The twin-tip design with
exposed sensor tips is available in a broader range of
materials and sustains higher
pressures. The spherical tip
design (only available in
316L stainless steel) offers
greater sensor protection
and a faster response to
reduction flow or level.
Thermatel level switches provide outstanding performance with liquids and slurries in a wide variety of
demanding applications including interface, high viscosity,
turbulence, high temperatures, and presence of foam.
For mass flow measurement of air and gases, the
Thermatel TA2 Thermal Mass Flow Transmitter is
without peer. The easy to use instrument is installed in
numerous flow measurement applications including
combustion air flow, compressed air/gas and aeration air
flow measurement. Other common applications include
natural gas, digester/bio gas, flare lines, hydrogen, oxygen,
and many other gas flow measurement applications.
Principle of Operation: Switches
Flow and level detection is accomplished when
Thermatel’s sensing elements detect changes in the heat
transfer characteristics of the process media. As a flow
switch, Thermatel switches will rapidly detect changes in
liquid or gas flow rate by detecting heat transfer, which
increases at higher flow rates. Level detection is accomplished by sensing changes in the thermal conductivity of
media. Thermatel switches can also be calibrated to
sense difference in heat transfer at the interface between
two dissimilar media, such as oil/water, or water/foam.
Reference
RTD
Active
RTD
Mass
balancing
element
Heater
Power
Transmitter
Mass Flow
Thermatel switches rely on two miniature sensing
elements to detect heat transfer. Resistance Temperature
Detectors (RTDs) establish a thermal relationship that
establishes the basis for flow and level detection. One
RTD measures the temperature of the surrounding media
which serves as the instrument’s reference temperature.
The second RTD is heated to establish a temperature
differential above the reference temperature. In flow
sensing applications, the heated RTD cools with increasing flow. In level sensing applications, the RTD cools in
the presence of media. In each case, cooling the heated
RTD decreases the differential temperature between the
two RTDs. This decrease is then converted into a relay
actuation which performs an alarm function.
Principle of Operation: Flow Meter
Thermal dispersion technology provides a mass flow
measurement of air or gas. This is accomplished by
precisely measuring the cooling effect as the mass (molecular) flow passes the heated sensor. The sensor consists
of two elements: the reference which measures the temperature of the gas and a second element which is heated at a variable power. This maintains the desired temperature difference between the two sensors.
Each instrument is factory calibrated and configured
for the specific application. If necessary, the TA2 can be
reconfigured in the field for different conditions.
Strengths and Cautions
Direct mass flow measurement—does not require
pressure or temperature compensation which is
required by other technologies.
Thermatel offers excellent low flow sensitivity:
gas velocities from 25 ft/min (0.13 m/s) to over
50,000 ft/min (255 m/s).
Thermatel products are easy to install and
can be “hot tapped.”
An alternative flow meter technology should
be considered where condensed moisture is
continuously present.
Refer to Magnetrol bulletin 54-621 for further technical
information on Thermal Dispersion Mass Flow.
The illustration on the top of this page shows the
amount of power required to maintain a constant temperature difference between the two sensors. Under low
mass flow conditions, there is minimal cooling and little
power is required. As the mass flow increases, more
power is required. This provides excellent low flow
sensitivity and high turndown capabilities.
5
THERMATEL TA2 Thermal Mass Flow Transmitter
Mass Flow Measurement of Air and Gas
General Description:
The Magnetrol TA2 Thermal Dispersion Mass Flow Transmitter provides
direct mass flow measurement of air and gases. The powerful microprocessor-based electronics provide an instrument that is easy to
configure to the application, yet provides flexibility and ease of use.
Advanced temperature compensation provides high performance over the
entire operating range of the instrument. Installed cost of this instrument
is very competitive with other gas mass flow measurement technologies.
L
Technology Features:
Direct mass flow measurement in SCFM, SCFH, MMSCFD,
Nm3/h, lb/hr, kg/hr
L L L L
Excellent low flow sensitivity
High turndown ratios
Ease of installation
Low pressure drop
Applications:
Typical applications include combustion air-flow measurement,
Model TA2
Mass Flow Transmitter
compressed air, natural gas flow, flare lines, digester/bio gas, and other
process gas flow measurement.
Model TA2
Mass Flow Transmitter
In The Magnetrol Product Calibration Lab,
Thermatel products are calibrated and tested to meet
customer specifications. Calibrations traceable to NIST.
Model TA2
with Flow Body
6
THERMATEL TA2
L L L L L L L L L L L L L L L L L L L L
Product Features:
Accepts all typical input powers in same unit
Second mA output for temperature output or second flow range optional
Pulse output optional
Integral or remote electronics
Rotatable housing to permit viewing the display from any position
Pre-calibrated and configured for the user’s application. Ready to install.
Flow totalization
Ability to replace probe/circuit boards in field
EGRITY
Insertion probes and flow body designs
F ET Y I
NT
All explosion proof housing with FM, FMc, and ATEX hazardous area approval
SA
V EL
LE
Stainless steel and Hastelloy probes with wide selection of process connections
On-site calibration verification procedure
PACTware™ for configuration, diagnostics, and trending
SIL 1 with SFF value of 88.4%
NIST traceable calibration
Optional hot tap assembly
HART®, AMS communication
Ability to replace probe in field
4-button keypad for data entry
Two gas calibrations available
APPROVALS
S P E C I F I C AT I O N S
Supply Voltage
11.6 to 30 VDC
100 to 264 VAC
7 VA typical
Power Consumption
Flow Range Maximum
10–50,000 SFPM (0.05–250 Nm/s) air reference to standard conditions
Higher ranges and other gases available
Accuracy Flow
±1% of reading +0.5% of calibrated full scale
Accuracy Temperature
±2° F (1° C)
Repeatability
±0.5% of reading
Turn Down
100:1 typical (depending on calibrated flow range)
Ambient Temperature
-40° to +176° F (-40° to +80° C);
display not readable below -22° F (-30° C)
Process Temperature
-50° to +400° F (-45° to +200° C)
Pressure Rating
1500 psig (103 bar) maximum
Analog Output Signal
Active: 4–20 mA (isolated) maximum 1000 Ω loop resistance
Passive: 4–20 mA (isolated) loop resistance dependent on power supply
HART
Optional
7
THERMATEL TD1 & TD2 Switches
Flow / Level / Interface Detection
General Description:
The TD1/TD2 Thermatel switch is extremely versatile providing
flow/level/interface detection in a single unit. Both liquid and gas flow
detection is obtainable. The TD1 is available with 24 VDC power with the
TD2 available in either an AC or DC version. The TD2 also provides LED
indication through an optional glass window, mA output for diagnostics or
repeatable flow/level indication, optional hermetically sealed relay, time
delay adjustment, and remote electronics. Continuous diagnostics on both
units provides assurance that the switch is operating properly.
L L L L L L L L L L L L
Features:
Continuous diagnostics
Temperature compensation
No moving parts
Narrow hysteresis
Operating temperatures to +850° F (+450° C)
Integral or remote electronics
8-amp DPDT relay with optional hermetically sealed relay
Low flow sensing capabilities
Probes available in 316 stainless steel, Hastelloy® C, and Monel®
Wide selection of sensors – see page 10
NACE construction available
Hygienic design available
Applications:
Flow: Pump protection, relief valve monitoring, low flow/high flow indication,
cooling air/water, exhaust flow, analyzer lines, lubrication systems
Level: High level/low level/interface detection, high viscosity liquids, slurries,
high pressure, high temperature, air/foam and foam/liquid detection,
corrosive environments
APPROVALS
S P E C I F I C AT I O N S
Input Power
TD1: 19.2 to 28.8 VDC
TD2: 100 to 264 VAC, 50–60 Hz or 19.2 to 28.8 VDC
Power Consumption
TD1: 3.5 watts at 24 VDC, 4.5 watts at 30 VDC
TD2: 4 watts at 24 VDC, 4.5 watts at 30 VDC, 5 watts at 100 to 264 VAC
Power to Probe
Electronics
Less than 1 watt
TD1: Integral
TD2: Integral or remote
Relay
Set Point Range
8-amp DPDT — TD2 has optional hermetically sealed relay
Water: 0.01 to 5 fps (0.003 to 1.5 m/s)
Air: 0.1 to 500 sfps (0.3 to 150 nm/s)
8
Process Temperature
-100° to +850° F (-73° to +454° C)
Process Pressure
Probe dependent — to 6000 psig (414 bar)
THERMATEL TG1 Switch
Two-Wire Intrinsically Safe Flow / Level / Interface Detection
General Description:
The Magnetrol TG1/TG2 switch is the industry’s only two-wire,
intrinsically-safe thermal dispersion switch. The switch consists of
a probe and preamplifier with remote DIN rail electronics. Barriers
in the DIN rail enclosure provide a two-wire, intrinsically-safe circuit
to the probe/preamplifier.
Product Operation:
The preamplifier converts the temperature difference to a pulse
signal which is super-imposed on the two wires providing power
to the sensor. The DIN rail electronics provide operation control
including set point adjustment, LED indication of flow/level, relay,
fail-safe adjustment, and time delay. A non-linear mA output signal
is available for diagnostics and repeatable flow/level indication.
L
Features:
DIN rail mounted electronics with built-in barrier provide a
two-wire intrinsically-safe circuit to the probe/preamplifier
L L L L L
Versatile switch for flow and level
Set point adjustment at remote electronics
Up to 1,650 feet (500 meters) cable length
LED indication provides monitoring of actual flow/level
mA output signal will provide repeatable indication plus
can be used for diagnostics
L
Uses all Thermatel probes including low flow body and
high-temperature sensor
Applications:
Flow: Liquid or gas flow, pump protection, cooling air/water, relief
valves, flow/no flow
Level: Hi/Low level, high viscosity media, high solids content,
aeration/foaming, hygienic applications, interface detection,
high-temperature applications
APPROVALS
S P E C I F I C AT I O N S
Supply Voltage
24 VDC
Relay
2-amp, SPDT relay
Signal
mA output, non-linear
Fail-safe
Switch selectable
LED Indication
4 Green: Flow/Level is normal
1 Yellow: Flow/Level is near
set point
Operating Temperature
Sensor: -100° to +850° F
(-70° to +450° C)
Flow Range Insertion Probes
Water: 0.01 – 5 fps
(0.003 to 1.5 m/s)
Air: 0.1 – 500 fps
(150 m/s)
1 Red: Alarm condition (TG1 only)
Set-Point
Adjustable via
potentiometer
9
THERMATEL Switch Sensors
Twin-Tip Sensors are mounted at the end of each tip.
Spherical Sensors are bonded directly to the wall of
the tip for greater sensitivity and sensor protection.
Probe pressure and temperature ratings are dependent
upon process connection; maximum pressure and
temperature ratings are shown below.
Twin-Tip Sensor
General Use:
General purpose and corrosive resistant applications
Material Options:
316 stainless steel, Hastelloy C-276, or Monel
Process Connections:
NPT threads, G threads, ANSI flanges, EN/DIN flanges
Max Temperature:
+400° F (+200° C)
Max Pressure:
3,000 psig (207 bar) – 1850 psi (127 bar) extended length
Insertion Lengths:
2 to 130 inches (50 to 3,300 mm)
Spherical-Tip Sensor
General Use:
General purpose service and high-viscosity applications
Material:
316 stainless steel
Process Connections:
NPT threads, G threads, ANSI flanges, EN/DIN flanges, hygienic
Max Temperature:
+400° F (+200° C)
Max Pressure:
600 psi (40 bar)
Insertion Lengths:
2 to 130 inches (50 to 3,300 mm)
High-Temperature Sensor
General Use:
For high-temperature process environments
Material:
316 stainless steel; Hastelloy C-276
Process Connections:
NPT threads, G threads, ANSI flanges, EN/DIN flanges
Max Temperature:
+850° F (+454° C)
Max Pressure:
6,000 psi (413 bar)
Insertion Lengths:
2 to 36 inches (50 to 900 mm)
Low Flow Body Sensor
General Use:
Low flow detection; suitable for chemical
feed pumps, additive flow, pump seals,
process analyzers
Material:
316 stainless steel
Flow Rate:
0.055 to 3 gallons/hour
(0.02 to 11.5 liters/hr.)
Process Connections:
1
Max Temperature:
+400° F (+200° C)
Max Pressure:
5,800 psi (400 bar)
⁄4" and 1⁄2" NPT, and G threads
Mini Sensor
10
General Use:
Probes specifically designed to fit into a 1⁄2", 3⁄4", or 1" Tee
Material:
316 stainless steel
Max Temperature:
+400° F (+200° C)
Max Pressure:
3,000 psig (207 bar) – 1850 psi (127 bar) extended length
Insertion Length:
1 to 130 inches (25 to 3300 mm)
THERMATEL 052-7201 Switch
Flow Switch for Naval Applications
General Description:
The Thermatel “Navy Switch” is a special version of the Thermatel
switch. It is used by the United States Navy for use on board Naval
ships for flow detection in sprinkler systems.
Features:
L Meets MIL-S-901D: Grade A shock requirements
L Meets MIL-STD-167-1: Vibration requirements
L Unit comes with Tee for use with MIL-T-16420 CUNI tubing
(For tubing sizes: 1.25", 1.50", 2.00", 2.50", 3.00" or 4.00")
L 120 VAC power
L 10 amp DPDT relay
L Calibrated for sprinkler systems to detect flow of 10 GPM with
10-second delay time
THERMATEL RPA Hot Tap Assembly
Allows probe installation or removal without process shut-down
General Description:
When used with Thermatel insertion probes, the
Retractable Probe Assembly (RPA) permits the probe to
be installed or removed from the vessel or pipe while the
process remains in operation. Once installed, it is not
necessary to drain or depressurize a tank or shut down
the operation in order to install or remove a Thermatel
instrument.
Features:
L Standard 316 stainless steel gland construction
L Carbon steel or stainless steel process connections
L Flange and ball valve available as an option
L 11⁄2" NPT or flange connection
L Teflon® compression rings
Capabilities:
L Temperatures to +400° F (+200° C)
L Standard pressure to 50 psi (3.4 bar)
(80 psi (5.5 bar) for TA2)
L High-pressure design option to
Class 300 pound service
Thermatel Hot Tap Assemblies:
Standard Design (Left) and
High Pressure Design (Right).
11
CORPORATE HEADQUARTERS
5300 Belmont Road • Downers Grove, Illinois 60515-4499 USA
Phone: 630-969-4000 • Fax: 630-969-9489
www.magnetrol.com • [email protected]
EUROPEAN HEADQUARTERS
Heikensstraat 6 • 9240 Zele, Belgium
Phone: 052 45.11.11 • Fax: 052 45.09.93
BRAZIL: Av. Dr. Mauro Lindemberg Monteiro • 185-Jd. Santa Fé, Osasco • São Paulo CEP 06278-010
CANADA: 145 Jardin Drive, Units 1 & 2 • Concord, Ontario L4K 1X7
CHINA: Plant 6, No. 191, Huajin Road • Minhang District • Shanghai 201109
DEUTSCHLAND: Alte Ziegelei 2–4 • D-51491 Overath
DUBAI: DAFZA Office 5AE 722, P.O. Box 293671 • Dubai, United Arab Emirates
INDIA: C-20 Community Centre • Janakpuri, New Delhi 110 058
ITALIA: Via Arese, 12 • 20159 Milano
SINGAPORE: 33 Ubi Avenue 3 • #05-10 Vertex • Singapore 408868
UNITED KINGDOM: Regent Business Centre • Jubilee Road • Burgess Hill, West Sussex RH15 9TL
Magnetrol® & Magnetrol logotype and Thermatel® are registered trademarks of Magnetrol International.
Hastelloy® is a registered trademark of Haynes International, Inc.
HART® is a registered trademark of the HART Communication Foundation
Modbus® is a registered trademark of Gould, Inc.
Monel® is a registered trademark of Special Metals Corporation (Formerly Inco Alloys International)
Copyright © 2011 Magnetrol International. All rights reserved. Printed in the USA.
Bulletin: 54-100.4 • Effective: March 2011