Eclipse 706 Guided Wave Radar Level Application Questionnaire (Please complete both pages.) REFERENCE INFORMATION Customer/Company: City, State, Country: SIC: Date: Contact/Title: Phone: Fax: RFQ Number: E-mail: P. O. Number: FOR OFFICE USE: Tag Number(s): Submitted by: Rep Agency and Salesperson INSTRUMENT Rep Code: 7 0 6 Model Number: Electronics 5 Quantity: 7 Sensor/Probe Notes: 1. When Probe Models 7yF, 7yM, 7yN, 7y1, 7y2, 7y5, and 7y7 are ordered, Figures 1 & 2 must be completed. 2. Torque tube replacements must confirm flange dimensions in Figure 3. 3. Customer is responsible for material compatibility. PROCESS DATA - NOTE: FOR COMPLETE PRE-CONFIGURATION SHADED AREAS MUST BE COMPLETED Process Name/Description: Process Media: Steam present: c Yes c Liquid: c No If yes, use Aegis PF128 O-ring or 7XS steam probe c Slurry % Solids % Concentration Process Temperature: c AMB c ATMOS Process Pressure: Temperature at Instrument: c AMB Media Constants: c Interface max. min. max. min. max. Dielectric Constant: Environment: c Normal c Yes: c Corrosive c FM c CSA c °F c Film or c Bridging c Salt c Flood c Horizontal Cylindrical Vessel Size: Height Tank Material of Construction: c Metal Type of Filling: c Top Liquid Surface: c Calm c Bottom Width c°C c Other c °C c Solids c Bar Varies? c No % Moisture: Diameter c Side (At what level? c No c Intrinsically Safe c Vortex c Sump/Pit centipoise c ASME B31.1 c Other c Plastic ) Foam Present: c Yes c Yes Div c SIL 2 Unit of Measure Agitation: c No c Yes c During Filling c During Emptying c Between Fill and Empty to ) c Nonincendive c O.C.F. Does the process contain higher dielectric “water-bottoms that need to be ignored?” c Yes Other Objects in Vessel: c No c Yes, from c Hazardous: Cl Coated: c Yes c No c Flowing c Other Bulk Density: Construction Code: c Industrial c Sphere c KPA c Yes (If yes, thickness: Maximum Viscosity: Lined: c Yes c No c Moderate Turbulence Does liquid boil and/or flash: c Yes c°F (µ siemen/cm) c ATEX EEx Hazardous Area Design: c Explosion-proof Vessel Type: c Vertical Cylindrical c Other Area Classification: c General Purpose (Nema 4X) Remote Instrument (if applicable): Required Materials of Construction: c°C Emulsion Layer: c No Centipoise @ Temperature Will media coat probe? c No c°F c PSIG Conductivity: Dielectric of lower material: Viscosity: Agency: min. Group c Other c ASME B31.3 c Concrete c No c No # and Size of Blades RPM (Include sketch on back.) Minimum distance from probe rod to any metallic object (i.e., nozzle, tank wall, ladder, etc.): Foundation Fieldbus Host System: PERFORMANCE Measurement requirement (with respect to the bottom of the vessel): What is the maximum level height of the material?: 4mA (0%) point is: What is the minimum level height of the material?: 20mA (100%) point is: The typical operating level is Unit of Measure: Accuracy Required: During filling: % During emptying: When level is stationary: % When level is stationary and agitated: % % High Level Shutdown/Overfill Protection Special consideration is necessary in any application for High Level Shutdown/Overfill protection. To ensure highest measurement, accuracy, use an Overfill capable probe, or install all other probes so the maximum overfill level is a minimum of 6" (150mm) below the process connection. This may include utilizing a nozzle or spool piece to raise the probe. Consult factory for further information. BULLETIN: 57-346.0 FIGURE 2 - NON-ANSI FLANGES When attempting to mate to an existing torque tube transmitter cage flange, confirm flange dimensions below. FIGURE 1 Sensor Reference Point 5.625 Ø (143) 7.25 Ø (184) 9.0 Ø (229) Sensor Reference Point 4.750 Ø (121) 45° 20 mA Measurement Region 4 mA Measurement Region 45° .875 Ø (22) .438 Ø (11) 1.125 (32) Level -Level Offset Level +Level Offset 5.23 (133) c 3.375 (86) .22 (6) 5.875 Ø (149) .188 (5) Fisher 249C (600 lb.), 316 stainless steel c Fisher 249B/259B (600 lb.), carbon steel 7.50 Ø (191) 1.125 (29) ______ Ø ______ Ø 45° 45° .875 Ø (22) ______ Ø 1.125 (29) 4.00 (102) c ______ .25 (6) ______ c Masoneilan (600 lb.), carbon steel ______ Other (Provide Dimensions) FIGURE 3 - RECOMMENDED SINGLE ROD PROBE CLEARANCE TABLE Distance to Probe Acceptable Objects < 6" Continuous, smooth, parallel conductive surface, for example a metal tank wall; important that probe does not touch wall > 6" <1" (25mm) diameter pipe and beams, ladder rungs > 12" <3" (75mm) diameter pipe and beams, concrete walls > 18" All remaining objects FIGURE 4 - NOZZLES – Single Rod Probes C A = Diameter B = Length A B C = Mounting NOTES 1. 705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489 [email protected] • www.magnetrol.com A divided by B ≥ 1 for optimum performance. should be BULLETIN: 57-346.1 EFFECTIVE: September 2013 SUPERSEDES: January 2013