57-346.1 Eclipse Model 706 Questionnaire

Eclipse 706 Guided Wave Radar
Level Application Questionnaire
(Please complete both pages.)
REFERENCE INFORMATION
Customer/Company:
City, State, Country:
SIC:
Date:
Contact/Title:
Phone:
Fax:
RFQ Number:
E-mail:
P. O. Number:
FOR OFFICE USE:
Tag Number(s):
Submitted by: Rep Agency and Salesperson
INSTRUMENT
Rep Code:
7 0 6
Model Number: Electronics
5
Quantity:
7
Sensor/Probe
Notes: 1. When Probe Models 7yF, 7yM, 7yN, 7y1, 7y2, 7y5, and 7y7 are ordered, Figures 1 & 2 must be completed.
2. Torque tube replacements must confirm flange dimensions in Figure 3.
3. Customer is responsible for material compatibility.
PROCESS DATA - NOTE: FOR COMPLETE PRE-CONFIGURATION SHADED AREAS MUST BE COMPLETED
Process Name/Description:
Process Media:
Steam present: c Yes
c Liquid:
c No
If yes, use Aegis PF128 O-ring or 7XS steam probe
c Slurry % Solids
% Concentration
Process Temperature: c AMB
c ATMOS
Process Pressure:
Temperature at Instrument: c AMB
Media Constants:
c Interface
max.
min.
max.
min.
max.
Dielectric Constant:
Environment: c Normal
c Yes:
c Corrosive
c FM
c CSA
c °F
c Film or c Bridging
c Salt
c Flood
c Horizontal Cylindrical
Vessel Size: Height
Tank Material of Construction: c Metal
Type of Filling: c Top
Liquid Surface: c Calm
c Bottom
Width
c°C
c Other
c °C
c Solids
c Bar
Varies? c No
% Moisture:
Diameter
c Side (At what level?
c No
c Intrinsically Safe
c Vortex
c Sump/Pit
centipoise
c ASME B31.1
c Other
c Plastic
)
Foam Present: c Yes
c Yes
Div
c SIL 2
Unit of Measure
Agitation: c No c Yes c During Filling c During Emptying c Between Fill and Empty
to
)
c Nonincendive
c O.C.F.
Does the process contain higher dielectric “water-bottoms that need to be ignored?” c Yes
Other Objects in Vessel: c No
c Yes, from
c Hazardous: Cl
Coated: c Yes c No
c Flowing
c Other
Bulk Density:
Construction Code: c Industrial
c Sphere
c KPA
c Yes (If yes, thickness:
Maximum Viscosity:
Lined: c Yes c No
c Moderate Turbulence
Does liquid boil and/or flash: c Yes
c°F
(µ siemen/cm)
c ATEX EEx Hazardous Area Design: c Explosion-proof
Vessel Type: c Vertical Cylindrical
c Other
Area Classification: c General Purpose (Nema 4X)
Remote Instrument (if applicable):
Required Materials of Construction:
c°C
Emulsion Layer: c No
Centipoise @ Temperature
Will media coat probe? c No
c°F
c PSIG
Conductivity:
Dielectric of lower material:
Viscosity:
Agency:
min.
Group
c Other
c ASME B31.3
c Concrete
c No
c No
# and Size of Blades
RPM
(Include sketch on back.)
Minimum distance from probe rod to any metallic object (i.e., nozzle, tank wall, ladder, etc.):
Foundation Fieldbus Host System:
PERFORMANCE
Measurement requirement (with respect to the bottom of the vessel):
What is the maximum level height of the material?:
4mA (0%) point is:
What is the minimum level height of the material?:
20mA (100%) point is:
The typical operating level is
Unit of Measure:
Accuracy Required:
During filling:
% During emptying:
When level is stationary:
%
When level is stationary and agitated:
%
%
High Level Shutdown/Overfill Protection
Special consideration is necessary in any
application for High Level Shutdown/Overfill
protection. To ensure highest measurement,
accuracy, use an Overfill capable probe, or
install all other probes so the maximum
overfill level is a minimum of 6" (150mm)
below the process connection. This may
include utilizing a nozzle or spool piece to
raise the probe. Consult factory for further
information.
BULLETIN: 57-346.0
FIGURE 2 - NON-ANSI FLANGES
When attempting to mate to an existing torque tube transmitter cage flange,
confirm flange dimensions below.
FIGURE 1
Sensor
Reference
Point
5.625 Ø
(143)
7.25 Ø
(184)
9.0 Ø
(229)
Sensor Reference Point
4.750 Ø
(121)
45°
20 mA
Measurement
Region
4 mA
Measurement
Region
45°
.875 Ø
(22)
.438 Ø
(11)
1.125
(32)
Level
-Level
Offset
Level
+Level
Offset
5.23
(133)
c
3.375
(86)
.22
(6)
5.875 Ø
(149)
.188
(5)
Fisher 249C (600 lb.), 316 stainless steel
c
Fisher 249B/259B (600 lb.), carbon steel
7.50 Ø
(191)
1.125
(29)
______ Ø
______ Ø
45°
45°
.875 Ø
(22)
______ Ø
1.125
(29)
4.00
(102)
c
______
.25
(6)
______
c
Masoneilan (600 lb.), carbon steel
______
Other (Provide Dimensions)
FIGURE 3 - RECOMMENDED SINGLE ROD PROBE CLEARANCE TABLE
Distance
to Probe
Acceptable Objects
< 6"
Continuous, smooth, parallel conductive surface, for example
a metal tank wall; important that probe does not touch wall
> 6"
<1" (25mm) diameter pipe and beams,
ladder rungs
> 12"
<3" (75mm) diameter pipe and beams,
concrete walls
> 18"
All remaining objects
FIGURE 4 - NOZZLES – Single Rod Probes
C
A = Diameter
B = Length
A
B
C = Mounting
NOTES
1.
705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000 • Fax 630-969-9489
[email protected] • www.magnetrol.com
A divided by B
≥ 1 for optimum performance.
should
be
BULLETIN: 57-346.1
EFFECTIVE: September 2013
SUPERSEDES: January 2013