AOZ8831-05 Ultra Low Capacitance One-line Bi-directional TVS Diode General Description Features The AOZ8831-05 is an ultra low capacitance one-line bi-directional transient voltage suppressor diode designed to protect high speed data lines and voltage sensitive electronics from high transient conditions and ESD. ESD protection for high-speed data lines: – Exceeds: IEC 61000-4-2 (ESD) ±20kV (air), ±20kV (contact) – Human Body Model (HBM) ±15kV Small package saves board space This device incorporates one TVS diode in an ultra-small DFN 1.0 x 0.6 package. It may be used to meet the ESD immunity requirements of IEC 61000-4-2, Level 4. Ultra low capacitance: 0.22pF Low clamping voltage Operating voltage: 5V The AOZ8831-05 comes in an RoHS compliant DFN package and is rated over a -40°C to +85°C ambient temperature range. Pb-free device The ultra-small 1.0 x 0.6 x 0.4mm DFN package makes it ideal for applications where PCB space is a premium. The small size and high ESD protection makes it ideal for protecting voltage sensitive electronics from high transient conditions and ESD. Portable handheld devices Notebook computers Digital Cameras Portable GPS Typical Application Pin Configuration Applications Signal Line 1 2 Bidirection Protection of Single Line Rev. 1.0 November 2014 www.aosmd.com Page 1 of 7 AOZ8831-05 Ordering Information Part Number Ambient Temperature Range Package Environmental AOZ8831DT-05 -40°C to +85°C DFN 1.0 x 0.6 Green Product AOS Green Products use reduced levels of Halogens, and are also RoHS compliant. Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information. Absolute Maximum Ratings Exceeding the Absolute Maximum ratings may damage the device. Parameter Rating VP – VN 5.5V Peak Pulse Current (IPP), tP = 8/20µs 6A Peak Pulse Power (IEC61000-4-5 8/20µs current pulse) 90W Storage Temperature (TS) -65°C to +150°C ESD Rating per IEC61000-4-2, Contact ±20kV Air(1) ±20kV Model(2) ±15kV ESD Rating per IEC61000-4-2, ESD Rating per Human Body (1) Notes: 1. IEC 61000-4-2 discharge with CDischarge = 150pF, RDischarge = 330Ω. 2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100pF, RDischarge = 1.5kΩ. Maximum Operating Ratings Parameter Rating Junction Temperature (TJ) Rev. 1.0 November 2014 -40°C to +125°C www.aosmd.com Page 2 of 7 AOZ8831-05 Electrical Characteristics TA = 25°C unless otherwise specified. Symbol Parameter Diagram IPP Maximum Reverse Peak Pulse Current(3) (IEC61000-4-5 8/20µs pulse) VCL Clamping Voltage @ IPP(3) VRWM IR VBR CJ I IPP Working Peak Reverse Voltage Maximum Reverse Leakage Current VCL VBR VRWM IR IT Breakdown Voltage VRWM VBR VCL V Capacitance @ VR = 0 and f = 1MHz IPP Device Device VRWM (V) Marking Max. AOZ8831DT-05 5 5.5 VBR (V) Min. Max. IR (µA) Max. 6 10 0.1 VCL Max. IPP = 1 A IPP = 4 A 4 9.5 CJ (pF) IPP = 6 A Typ. Max. 15 0.22 0.35 Notes: 3. These specifications are guaranteed by design and characterization. Rev. 1.0 November 2014 www.aosmd.com Page 3 of 7 AOZ8831-05 Performance Characteristics Clamping Voltage vs. Peak Pulse Current Typical Variations of CIN vs. VR (IEC 61000-4-5 8/20µs current pulse) 16 (f = 1MHz, T = 25ºC) 1.0 0.9 0.8 Normalized Capacitance Clamping Voltage, VCL (V) 14 12 10 8 6 0.7 0.6 0.5 0.4 0.3 0.2 4 0.1 0 2 0 1 2 3 4 Peak Pulse Current, IPP (A) Rev. 1.0 November 2014 5 6 www.aosmd.com 0 1.0 2.0 3.0 Input Voltage (V) 4.0 5.0 Page 4 of 7 AOZ8831-05 Package Dimensions, DFN 1.0 x 0.6 A D Pin #1 ID 0.125x45° E e 2xL O ddd M C A B A1 Seating Plane 2xb O ddd M C A B C SIDE VIEW BOTTOM VIEW RECOMMENDED LAND PATTERN 1.00 0.70 0.40 0.30 0.55 0.30 0.125x45° Dimensions in millimeters Symbols A A1 b D E e L ccc ddd Min. 0.31 0.00 0.45 0.55 0.95 Nom. 0.38 0.02 0.50 0.60 1.00 0.65 BSC 0.20 0.25 0.03 0.10 Max. 0.40 0.05 0.55 0.65 1.05 0.30 Dimensions in inches Symbols A A1 b D E e L ccc ddd Min. 0.012 0.000 0.018 0.022 0.037 Nom. Max. 0.015 0.016 0.001 0.002 0.020 0.022 0.024 0.026 0.039 0.041 0.026 BSC 0.008 0.010 0.012 0.001 0.004 UNIT: mm Notes: 1. All dimensions are in millimeters, angles are in degrees. 2. Coplanarity applies to the exposed heat sink slug as well as the terminals. Rev. 1.0 November 2014 www.aosmd.com Page 5 of 7 AOZ8831-05 Tape and Reel Dimensions, DFN 1.0 x 0.6 Carrier Tape P1 P2 T D1 E1 E2 E B0 K0 P0 D0 A0 UNIT: mm Option A Package B0 A0 K0 DFN 1.0x0.6/ 0.69 1.19 0.66 DFN 1.0x0.6A ±0.05 ±0.05 ±0.05 (8 mm) 0.40 ±0.05 D1 E E1 1.50 8.00 1.75 ±0.10 +0.3/-0.1 ±0.10 E2 3.50 ±0.05 P0 2.00 ±0.05 P1 4.00 ±0.10 T P2 0.23 2.00 ±0.05 ±0.02 B 0.61 DFN 1.0x0.6/ 0.65 1.05 DFN 1.0x0.6A ±0.04 ±0.04 ±0.04 (8 mm) 0.40 ±0.05 1.50 8.00 1.75 ±0.10 +0.3/-0.1 ±0.10 3.50 ±0.05 2.00 ±0.10 4.00 ±0.10 2.00 0.20 ±0.05 ±0.05 D0 Reel W1 S G N M K V R H W UNIT: mm Tape Size Reel Size 8mm ø178 M ø178 ±0.5 N ø55 ±1 W 8.4 +1.5/-0 W1 Max. 14.4 H ø13.0 ±0.5 K Max. 10.1 S 2.0 ±0.5 G N/A R N/A V N/A Leader / Trailer & Orientation TVS Unit Per Reel: 10000pcs Trailer Tape 300mm Min. Components Tape Orientation in Pocket Leader Tape 500mm Min. Trailer Tape 300mm Min. Components Tape Orientation in Pocket Leader Tape 500mm Min. MOS Unit Per Reel: 10000pcs Rev. 1.0 November 2014 www.aosmd.com Page 6 of 7 AOZ8831-05 Part Marking 5 Product Number Code Date Code LEGAL DISCLAIMER Alpha and Omega Semiconductor makes no representations or warranties with respect to the accuracy or completeness of the information provided herein and takes no liabilities for the consequences of use of such information or any product described herein. Alpha and Omega Semiconductor reserves the right to make changes to such information at any time without further notice. This document does not constitute the grant of any intellectual property rights or representation of non-infringement of any third party’s intellectual property rights. LIFE SUPPORT POLICY ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. Rev. 1.0 November 2014 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.aosmd.com Page 7 of 7