Capped IDC 26-28 AWG: WTB INTERCONNECT 9175-700 The market and applications for simple and reliable discrete Wire-to-Board connectors continue to evolve. AVX first introduced the 9175 series of surface mountable Insulation Displacement Connectors (IDC) in 2006. Developed for harsh industrial and automotive applications, these connectors have been used in hundreds of applications from today’s “Smart Meter” all the way down to a simple sensor termination to a PCB. Size and performance has been one of the key factors for selecting this connector in terminating 26-28AWG wires to a PCB. The next generation of IDC connector moves beyond all of the technical and performance attributes to address the “User Friendliness” of the product. By changing the insulator from acting as a connector body and make it more like a contact carrier, the insulator becomes the wire location and insertion aid without any special tools. The wire is just inserted into the cap (no stripping required) and then pressed down to provide a secure “Gas Tight” termination. This configuration simplifies and cost reduces the entire wire termination process for connecting discrete wires to a PCB. APPLICATIONS FEATURES AND BENEFITS • Connecting discrete wire components to a PCB • Bringing power and signals onto a PCB • Daisy chaining PCB’s together to create a continuous string • Reference Product Specification 201-01-140 • IDC contact provides a gas-tight connection to the PCB for long term reliability • Plastic cap retains the contacts in position prior to automatic placement, then acts as the assembly tool to terminate the wires; no special tooling. • Tested to automotive levels on shock, vibration and temperature cycling for reliability • Identical contact and footprint pattern to the existing 9175 for full backward compatibility and functionality • The IDC contact reduces the total applied cost versus solder or crimp processes • Connectors are available in two configurations for maximum flexibility; End and Through Wire ELECTRICAL ENVIRONMENTAL MECHANICAL • Current Rating: 1 Amps / Contact • Voltage Rating: 150 VAC • Operating Temperature: -40ºC to +125ºC • • • • HOW TO ORDER 00X 00 9175 Prefix Series 70X Wire Gauge Size Cap Pre-Assembled Number of Ways No of Code Ways Details Pages 002 2 2&4 Pages 003 3 3&5 Code Accepted Wire Gauge Wire Insulation Min Ø 0.70 701 28 Gauge Solid or Stranded Max Ø 1.00 Min Ø 0.80 702 26 Gauge Solid or Stranded Max Ø 1.20 Insulator Material: Nylon UL94VO Contact Material: Phosphor Bronze Plating: Tin over Nickel Durability 3 Cycles X X Insulator Color 9 = UL White 8 = UL Black Special Order 6 Cap Options Code Cap Option 0 9 Description Allows wire to be terminated Through Wire at any point Terminates end of wire Wire Stop End Protected by stop face Detail Page 2-3 Pages 3-5 Plating Option 6 = Pure Tin all over Certification: UL File #E90723 1 Capped IDC 26-28 AWG: WTB 9175-700 INTERCONNECT 26-28 AWG 2 WAY IDC CONNECTOR THROUGH WIRE CAPPED IDC MOUNTED ON PCB Code 701 702 Wire Gauge 28AWG 26AWG Diameter A 1.10 1.30 NOTES: 1. 2 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION. PRE-ASSEMBLED THROUGH WIRE CAP. 2. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED CONDUCTOR. MAXIMUM INSULATOR 1.00 MM DIAMETER. 3. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY. 4. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO ELCO SPEC 201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL. 5. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140. 6. GENERAL TOLERANCE ±0.20 UNLESS STATED. 7. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000. 8. CONNECTOR OUTLINE. 9. CONTACT MATERIAL: TIN PLATED COPPER ALLOY. 10. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 1. 11. FOR UL CODES UL REFERENCE E90723 (US AND CANADA). PACKING DETAILS SUGGEST PCB LAYOUT 2 Capped IDC 26-28 AWG: WTB INTERCONNECT 9175-700 26-28 AWG 3 WAY IDC CONNECTOR THROUGH WIRE CAPPED IDC MOUNTED ON PCB Code 701 702 Wire Gauge 28AWG 26AWG Diameter A 1.10 1.30 NOTES: 1. 3 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION. PRE-ASSEMBLED THROUGH WIRE CAP. 2. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED CONDUCTOR. MAXIMUM INSULATOR 1.00 MM DIAMETER. 3. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY. 4. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO ELCO SPEC 201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL. 5. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140. 6. GENERAL TOLERANCE ±0.20 UNLESS STATED. 7. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000. 8. CONNECTOR OUTLINE. 9. CONTACT MATERIAL: TIN PLATED COPPER ALLOY. 10. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 1. 11. FOR UL CODES UL REFERENCE E90723 (US AND CANADA). PACKING DETAILS SUGGEST PCB LAYOUT 3 Capped IDC 26-28 AWG: WTB 9175-700 INTERCONNECT 26-28 AWG 2 WAY IDC CONNECTOR WIRE STOP CAPPED IDC MOUNTED ON PCB Code 701 702 Wire Gauge 28AWG 26AWG Diameter A 1.10 1.30 NOTES: 1. 2 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION. PRE-ASSEMBLED WIRE STOP CAP. 2. WIRE STOP CAP PROTECTS END OF WIRE. 3. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED CONDUCTOR. MAXIMUM INSULATOR 1.00 MM DIAMETER. 4. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY. 5. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO ELCO SPEC 201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL. 6. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140. 7. GENERAL TOLERANCE ±0.20 UNLESS STATED. 8. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000. 9. CONNECTOR OUTLINE. 10. CONTACT MATERIAL: TIN PLATED COPPER ALLOY. 11. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 1. 12. FOR UL CODES UL REFERENCE E90723 (US AND CANADA). PACKING DETAILS SUGGEST PCB LAYOUT 4 Capped IDC 26-28 AWG: WTB 9175-700 INTERCONNECT 26-28 AWG 3 WAY IDC CONNECTOR WIRE STOP CAPPED IDC MOUNTED ON PCB Code 701 702 Wire Gauge 28AWG 26AWG Diameter A 1.10 1.30 NOTES: 1. 3 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION. PRE-ASSEMBLED WIRE STOP CAP. 2. WIRE STOP CAP PROTECTS END OF WIRE. 3. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED CONDUCTOR. MAXIMUM INSULATOR 1.00 MM DIAMETER. 4. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY. 5. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO ELCO SPEC 201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL. 6. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140. 7. GENERAL TOLERANCE ±0.20 UNLESS STATED. 8. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000. 9. CONNECTOR OUTLINE. 10. CONTACT MATERIAL: TIN PLATED COPPER ALLOY. 11. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0. COLOR REFER TO PAGE 1. 12. FOR UL CODES UL REFERENCE E90723 (US AND CANADA). PACKING DETAILS SUGGEST PCB LAYOUT 5 Capped IDC 26-28 AWG: WTB 9175-700 INTERCONNECT 26-28 AWG ASSEMBLED CAPPED IDC CONNECTORS MOUNTED ON PCB TYPICAL THROUGH WIRE ASSEMBLY TYPICAL WIRE STOP ASSEMBLY 6