Capped IDC 26-28 AWG: 9175-700 Datasheet

Capped IDC 26-28 AWG: WTB
INTERCONNECT
9175-700
The market and applications for simple and reliable discrete Wire-to-Board connectors
continue to evolve. AVX first introduced the 9175 series of surface mountable Insulation
Displacement Connectors (IDC) in 2006. Developed for harsh industrial and automotive
applications, these connectors have been used in hundreds of applications from today’s
“Smart Meter” all the way down to a simple sensor termination to a PCB. Size and
performance has been one of the key factors for selecting this connector in terminating
26-28AWG wires to a PCB.
The next generation of IDC connector moves beyond all of the technical and
performance attributes to address the “User Friendliness” of the product. By changing
the insulator from acting as a connector body and make it more like a contact carrier, the
insulator becomes the wire location and insertion aid without any special tools. The wire
is just inserted into the cap (no stripping required) and then pressed down to provide a
secure “Gas Tight” termination. This configuration simplifies and cost reduces the entire
wire termination process for connecting discrete wires to a PCB.
APPLICATIONS
FEATURES AND BENEFITS
• Connecting discrete wire components to a PCB
• Bringing power and signals onto a PCB
• Daisy chaining PCB’s together to create a
continuous string
• Reference Product Specification 201-01-140
• IDC contact provides a gas-tight connection to the PCB for long term
reliability
• Plastic cap retains the contacts in position prior to automatic placement,
then acts as the assembly tool to terminate the wires; no special tooling.
• Tested to automotive levels on shock, vibration and temperature cycling
for reliability
• Identical contact and footprint pattern to the existing 9175 for full backward compatibility and functionality
• The IDC contact reduces the total applied cost versus solder or crimp
processes
• Connectors are available in two configurations for maximum flexibility;
End and Through Wire
ELECTRICAL
ENVIRONMENTAL
MECHANICAL
• Current Rating: 1 Amps / Contact
• Voltage Rating: 150 VAC
• Operating Temperature:
-40ºC to +125ºC
•
•
•
•
HOW TO ORDER
00X
00 9175
Prefix
Series
70X
Wire Gauge Size
Cap Pre-Assembled
Number of Ways
No of
Code
Ways Details
Pages
002
2
2&4
Pages
003
3
3&5
Code
Accepted
Wire Gauge
Wire
Insulation
Min Ø 0.70
701 28 Gauge Solid or Stranded
Max Ø 1.00
Min Ø 0.80
702 26 Gauge Solid or Stranded
Max Ø 1.20
Insulator Material: Nylon UL94VO
Contact Material: Phosphor Bronze
Plating: Tin over Nickel
Durability 3 Cycles
X
X
Insulator Color
9 = UL White
8 = UL Black
Special Order
6
Cap Options
Code Cap Option
0
9
Description
Allows wire to be terminated
Through Wire
at any point
Terminates end of wire
Wire Stop
End Protected by stop face
Detail
Page
2-3
Pages
3-5
Plating
Option
6 = Pure Tin
all over
Certification: UL File #E90723
1
Capped IDC 26-28 AWG: WTB
9175-700
INTERCONNECT
26-28 AWG 2 WAY IDC CONNECTOR THROUGH WIRE CAPPED IDC
MOUNTED ON PCB
Code
701
702
Wire
Gauge
28AWG
26AWG
Diameter
A
1.10
1.30
NOTES:
1. 2 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION.
PRE-ASSEMBLED THROUGH WIRE CAP.
2. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED
CONDUCTOR. MAXIMUM INSULATOR 1.00 MM DIAMETER.
3. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY.
4. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO
ELCO SPEC 201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL.
5. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140.
6. GENERAL TOLERANCE ±0.20 UNLESS STATED.
7. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000.
8. CONNECTOR OUTLINE.
9. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
10. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0.
COLOR REFER TO PAGE 1.
11. FOR UL CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
SUGGEST PCB LAYOUT
2
Capped IDC 26-28 AWG: WTB
INTERCONNECT
9175-700
26-28 AWG 3 WAY IDC CONNECTOR THROUGH WIRE CAPPED IDC
MOUNTED ON PCB
Code
701
702
Wire
Gauge
28AWG
26AWG
Diameter
A
1.10
1.30
NOTES:
1. 3 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION.
PRE-ASSEMBLED THROUGH WIRE CAP.
2. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED
CONDUCTOR. MAXIMUM INSULATOR 1.00 MM DIAMETER.
3. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY.
4. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO
ELCO SPEC 201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL.
5. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140.
6. GENERAL TOLERANCE ±0.20 UNLESS STATED.
7. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000.
8. CONNECTOR OUTLINE.
9. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
10. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0.
COLOR REFER TO PAGE 1.
11. FOR UL CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
SUGGEST PCB LAYOUT
3
Capped IDC 26-28 AWG: WTB
9175-700
INTERCONNECT
26-28 AWG 2 WAY IDC CONNECTOR WIRE STOP CAPPED IDC
MOUNTED ON PCB
Code
701
702
Wire
Gauge
28AWG
26AWG
Diameter
A
1.10
1.30
NOTES:
1. 2 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION.
PRE-ASSEMBLED WIRE STOP CAP.
2. WIRE STOP CAP PROTECTS END OF WIRE.
3. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED CONDUCTOR.
MAXIMUM INSULATOR 1.00 MM DIAMETER.
4. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY.
5. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO ELCO SPEC
201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL.
6. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140.
7. GENERAL TOLERANCE ±0.20 UNLESS STATED.
8. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000.
9. CONNECTOR OUTLINE.
10. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
11. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0. COLOR
REFER TO PAGE 1.
12. FOR UL CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
SUGGEST PCB LAYOUT
4
Capped IDC 26-28 AWG: WTB
9175-700
INTERCONNECT
26-28 AWG 3 WAY IDC CONNECTOR WIRE STOP CAPPED IDC
MOUNTED ON PCB
Code
701
702
Wire
Gauge
28AWG
26AWG
Diameter
A
1.10
1.30
NOTES:
1. 3 WAY CONNECTOR FOR IDC WIRE TO BOARD CONNECTION.
PRE-ASSEMBLED WIRE STOP CAP.
2. WIRE STOP CAP PROTECTS END OF WIRE.
3. CONTACT/CAP TO MATCH 26AWG AND 28AWG WIRES. SOLID OR STRANDED CONDUCTOR.
MAXIMUM INSULATOR 1.00 MM DIAMETER.
4. FLAT FACE ON TOP OF CAP TO AID PICK AND PLACE ASSEMBLY.
5. FOR FULL PRODUCT SPECIFICATION ON STANDARD CONNECTORS REFER TO ELCO SPEC
201-01-139. UL COMPONENTS REFER TO ELCO SPEC 201-01-139UL.
6. ASSEMBLY PROCEDURE, REFER TO APPLICATION NOTES 201-01-140.
7. GENERAL TOLERANCE ±0.20 UNLESS STATED.
8. PACKED IN TAPE AND REEL, QUANTITY PER REEL 1000.
9. CONNECTOR OUTLINE.
10. CONTACT MATERIAL: TIN PLATED COPPER ALLOY.
11. INSULATOR MATERIAL: HIGH TEMPERATURE NYLON, GLASS FILLED, UL94 V-0. COLOR
REFER TO PAGE 1.
12. FOR UL CODES UL REFERENCE E90723 (US AND CANADA).
PACKING DETAILS
SUGGEST PCB LAYOUT
5
Capped IDC 26-28 AWG: WTB
9175-700
INTERCONNECT
26-28 AWG ASSEMBLED CAPPED IDC CONNECTORS
MOUNTED ON PCB
TYPICAL THROUGH WIRE ASSEMBLY
TYPICAL WIRE STOP ASSEMBLY
6