20131205080404 5878

Test Report.
No. CANEC1317866801
Date: 25 Nov 2013.
Page 1 of 8.
WINSEMI MICROELECTRONICS COMPANY LIMITED.
ROOM 1002,EAST,2,HIGH TECH PLAZA,TIANAN CYBER PARK,CHEGONGMIAO,SHENZHEN,P.R.CHINA
.
.
The following sample(s) was/were submitted and identified on behalf of the clients as : Wafer.
SGS Job No. :
CP13-059766 - SZ.
Supplier :.
WINSEMI.
Date of Sample Received :.
18 Nov 2013.
Testing Period :.
18 Nov 2013 - 22 Nov 2013.
Test Requested :.
Selected test(s) as requested by client..
Test Method :.
Please refer to next page(s)..
Test Results :.
Please refer to next page(s)..
Conclusion :.
Based on the performed tests on submitted samples, the results of Lead,
Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB),
Polybrominated diphenyl ethers (PBDE) comply with the limits as set by RoHS
Directive 2011/65/EU Annex II; recasting 2002/95/EC..
Signed for and on behalf of
SGS-CSTC Ltd..
Merry Lv.
Approved Signatory.
Test Report.
No. CANEC1317866801
Date: 25 Nov 2013.
Page 2 of 8.
Test Results :.
Test Part Description :.
Specimen No..
1.
SGS Sample ID.
CAN13-178668.001
Description.
“Wafer”.
Remarks :.
(1) 1 mg/kg = 1 ppm = 0.0001%.
(2) MDL = Method Detection Limit.
(3) ND = Not Detected ( < MDL ).
(4) "-" = Not Regulated.
RoHS Directive 2011/65/EU.
Test Method :. (1)With reference to IEC 62321-5:2013, determination of Cadmium by ICP-OES.
(2)With reference to IEC 62321-5:2013, determination of Lead by ICP-OES.
(3)With reference to IEC 62321-4:2013, determination of Mercury by ICP-OES.
(4)With reference to IEC 62321:2008, determination of Hexavalent Chromium by Colorimetric
Method using UV-Vis.
(5)With reference to IEC 62321:2008, determination of PBBs and PBDEs by GC-MS..
Test Item(s).
Limit.
Unit.
MDL.
001.
Cadmium (Cd).
100
mg/kg.
2
ND
Lead (Pb).
1,000
mg/kg.
2
ND
Mercury (Hg).
1,000
mg/kg.
2
ND
Hexavalent Chromium (CrVI).
1,000
mg/kg.
2
ND
Sum of PBBs.
1,000
mg/kg.
-
ND
Monobromobiphenyl.
-
mg/kg.
5
ND
Dibromobiphenyl.
-
mg/kg.
5
ND
Tribromobiphenyl.
-
mg/kg.
5
ND
Tetrabromobiphenyl.
-
mg/kg.
5
ND
Pentabromobiphenyl.
-
mg/kg.
5
ND
Hexabromobiphenyl.
-
mg/kg.
5
ND
Heptabromobiphenyl.
-
mg/kg.
5
ND
Octabromobiphenyl.
-
mg/kg.
5
ND
Nonabromobiphenyl.
-
mg/kg.
5
ND
Decabromobiphenyl.
Sum of PBDEs.
Monobromodiphenyl ether.
-
mg/kg.
5
ND
1,000
mg/kg.
-
ND
-
mg/kg.
5
ND
Test Report.
No. CANEC1317866801
Date: 25 Nov 2013.
Limit.
Unit.
MDL.
001.
Dibromodiphenyl ether.
-
mg/kg.
5
ND
Tribromodiphenyl ether.
-
mg/kg.
5
ND
Tetrabromodiphenyl ether.
-
mg/kg.
5
ND
Pentabromodiphenyl ether.
-
mg/kg.
5
ND
Hexabromodiphenyl ether.
-
mg/kg.
5
ND
Heptabromodiphenyl ether.
-
mg/kg.
5
ND
Octabromodiphenyl ether.
-
mg/kg.
5
ND
Nonabromodiphenyl ether.
-
mg/kg.
5
ND
Decabromodiphenyl ether.
-
mg/kg.
5
ND
Test Item(s).
Page 3 of 8.
Notes :.
(1) The maximum permissible limit is quoted from directive 2011/65/EU, Annex II.
Phthalate.
Test Method :. Determination of phthalates by GC-MS based on EN 14372:2004..
CAS NO.
Unit.
MDL.
001.
Dibutyl Phthalate (DBP).
84-74-2.
%(W/W).
0.003
ND
Benzylbutyl Phthalate (BBP).
85-68-7.
%(W/W).
0.003
ND
Bis-(2-ethylhexyl) Phthalate
(DEHP).
117-81-7.
%(W/W).
0.003
ND
Test Item(s).
Notes :.
(1) Reference Information: Directive 2011/65/EU recasting RoHS directive 2002/95/EC:
Bis (2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP) and Dibutyl phthalate (DBP) are considered as a priority for risk evaluation and substance restriction..
Hexabromocyclododecane (HBCDD).
Test Method :. Determination of HBCDD by GC-MS based on IEC 62321:2008..
Test Item(s).
Unit.
Hexabromocyclododecane (HBCDD).
mg/kg.
MDL.
001.
10
ND
Notes :.
(1) Reference Information: Directive 2011/65/EU recasting RoHS directive 2002/95/EC:
Hexabromocyclododecane (HBCDD) is considered as a priority for risk evaluation and substance Test Report.
restriction..
No. CANEC1317866801
Date: 25 Nov 2013.
Page 4 of 8.
Test Report.
No. CANEC1317866801
Date: 25 Nov 2013.
Page 5 of 8.
ATTACHMENTS
RoHS Testing Flow Chart
1) Name of the person who made testing: Michael Tso / Cutey Yu
2) Name of the person in charge of testing: Adams Yu / Yolanda Wei
3) These samples were dissolved totally by pre-conditioning method according to below flow chart
(Cr6+ and PBBs/PBDEs test method excluded).
Sample Preparation
Sample Measurement
Pb/Cd/Hg
Acid digestion with
microwave/ hotplate
Sample solvent
extraction
Filtration
Concentration/
Dilution of extraction
solution
Solution
Residue
Filtration
1) Alkali Fusion /
Dry Ashing
2) Acid to
dissolve
ICP-OES/AAS
DATA
Cr6+
PBBs/PBDEs
GC-MS
DATA
Nonmetallic
material
Adding digestion
reagent
Heating to
90~95℃ for
extraction
Filtration and
pH adjustment
Adding 1,5diphenylcarbazide
for color
development
Metallic
material
Positive
Spot test
Negative
Boiling water
extraction
Adding 1,5diphenylcarbazide
for color
development
UV-Vis
A red color
indicates the
presence of Cr6+. If
necessary, confirm
with UV-Vis.
DATA
DATA
Test Report.
No. CANEC1317866801
ATTACHMENTS
HBCDD Testing Flow Chart
1) Name of the person who made testing: Cutey Yu
2) Name of the person in charge of testing: Yolanda Wei
Sample cutting / preparation
Sample Measurement
Solvent extraction
Concentration/Dilution
Filtration
GC-MS
DATA
Date: 25 Nov 2013.
Page 6 of 8.
Test Report.
No. CANEC1317866801
ATTACHMENTS
Phthalates Testing Flow Chart
1) Name of the person who made testing: Liu Qiong
2) Name of the person in charge of testing: Yolanda Wei
Sample cutting / preparation
Sample Measurement
Solvent extraction
Concentration/Dilution
Filtration
GC-MS
DATA
Date: 25 Nov 2013.
Page 7 of 8.
Test Report.
No. CANEC1317866801
Date: 25 Nov 2013.
Sample photo:.
CANEC1317866801
CAN13-178668.001.
SGS authenticate the photo on original report only.
*** End of Report ***.
Page 8 of 8.