Test Report. No. CANEC1305766701 Date: 28 Apr 2013. Page 1 of 9. WINSEMI MICROELECTRONICS COMPANY LIMITED. ROOM 1002,EAST II,HIGH TEACH PLAZA,TIAN AN CYBERPARK,CHEGONGMIAO,SHENZHEN CHINA. . The following sample(s) was/were submitted and identified on behalf of the clients as : TO-220. SGS Job No. : CP13-019723 - SZ. Tested Sample Info. :. TO-220. Client Ref. Info. :. TO-92/TO-220F/TO-126/AB/TO-251/TO-252/IPAK/DPAK/TO-277/SOT-223/. SOT-89. Main Substance :. Si, Cu, Sn, Al, Ag, Epoxy Resin. Date of Sample Received :. 23 Apr 2013. Testing Period :. 23 Apr 2013 - 28 Apr 2013. Test Requested :. Selected test(s) as requested by client.. Test Method :. Please refer to next page(s).. Test Results :. Please refer to next page(s).. Conclusion :. Based on the performed tests on submitted samples, the results of Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB), Polybrominated diphenyl ethers (PBDE) comply with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.. Signed for and on behalf of SGS-CSTC Ltd.. Merry Lv. Approved Signatory. Test Report. No. CANEC1305766701 Date: 28 Apr 2013. Page 2 of 9. Test Results :. Test Part Description :. Specimen No.. 1. 2. 3. SGS Sample ID. CAN13-057667.001 CAN13-057667.002 CAN13-057667.003 Description. Silvery metal pin. Silvery metal sheet (without chip). Black plastic w/ black printing & chip. Remarks :. (1) 1 mg/kg = 1 ppm = 0.0001%. (2) MDL = Method Detection Limit. (3) ND = Not Detected ( < MDL ). (4) "-" = Not Regulated. RoHS Directive 2011/65/EU. Test Method :. With reference to IEC 62321:2008 (1) Determination of Cadmium by ICP-OES. (2) Determination of Lead by ICP-OES. (3) Determination of Mercury by ICP-OES. (4) Determination of Hexavalent Chromium by Colorimetric Method using UV-Vis. (5) Determination of PBBs / PBDEs content by GC-MS.. Test Item(s). Cadmium (Cd). Limit. Unit. MDL. 003. 100 mg/kg. 2 ND Lead (Pb). 1,000 mg/kg. 2 7 Mercury (Hg). 1,000 mg/kg. 2 ND Hexavalent Chromium (CrVI). 1,000 mg/kg. 2 ND Sum of PBBs. 1,000 mg/kg. - ND Monobromobiphenyl. - mg/kg. 5 ND Dibromobiphenyl. - mg/kg. 5 ND Tribromobiphenyl. - mg/kg. 5 ND Tetrabromobiphenyl. - mg/kg. 5 ND Pentabromobiphenyl. - mg/kg. 5 ND Hexabromobiphenyl. - mg/kg. 5 ND Heptabromobiphenyl. - mg/kg. 5 ND Octabromobiphenyl. - mg/kg. 5 ND Nonabromobiphenyl. - mg/kg. 5 ND Test Report. Test Item(s). Decabromobiphenyl. Sum of PBDEs. No. CANEC1305766701 Date: 28 Apr 2013. Limit. Unit. MDL. 003. - mg/kg. 5 ND 1,000 mg/kg. - ND Monobromodiphenyl ether. - mg/kg. 5 ND Dibromodiphenyl ether. - mg/kg. 5 ND Tribromodiphenyl ether. - mg/kg. 5 ND Tetrabromodiphenyl ether. - mg/kg. 5 ND Pentabromodiphenyl ether. - mg/kg. 5 ND Hexabromodiphenyl ether. - mg/kg. 5 ND Heptabromodiphenyl ether. - mg/kg. 5 ND Octabromodiphenyl ether. - mg/kg. 5 ND Nonabromodiphenyl ether. - mg/kg. 5 ND Decabromodiphenyl ether. - mg/kg. 5 ND Page 3 of 9. Notes :. (1) The maximum permissible limit is quoted from the directive 2011/65/EU, Annex II.. RoHS Directive 2011/65/EU. Test Method :. With reference to IEC 62321:2008 (1) Determination of Cadmium by ICP-OES. (2) Determination of Lead by ICP-OES. (3) Determination of Mercury by ICP-OES. (4) Determination of Hexavalent Chromium by Spot test / Colorimetric Method using UV-Vis.. Test Item(s). Cadmium (Cd). Limit. Unit. MDL. 001. 002. 100 mg/kg. 2 ND ND Lead (Pb). 1,000 mg/kg. 2 13 8 Mercury (Hg). 1,000 mg/kg. 2 ND ND - - ♢ Negative Negative Hexavalent Chromium (CrVI). Notes :. (1) The maximum permissible limit is quoted from the directive 2011/65/EU, Annex II (2)◇Spot-test: Negative = Absence of CrVI coating, Positive = Presence of CrVI coating; (The tested sample should be further verified by boiling-water-extraction method if the spot test result is Negative or cannot be confirmed.) ◇Boiling-water-extraction: Negative = Absence of CrVI coating Positive = Presence of CrVI coating; the detected concentration in boiling-water-extraction solution is equal or greater than 0.02 mg/kg with 50 cm2 sample surface area. Test Report. No. CANEC1305766701 Date: 28 Apr 2013. Page 4 of 9. Information on storage conditions and production date of the tested sample is unavailable and thus results of Cr(VI) represent status of the sample at the time of testing.. Hexabromocyclododecane (HBCDD). Test Method :. Determination of HBCDD by GC-MS based on IEC 62321:2008.. Test Item(s). Unit. Hexabromocyclododecane (HBCDD). mg/kg. MDL. 003. 10 ND Notes :. (1) Reference Information: Directive 2011/65/EU recasting RoHS directive 2002/95/EC: Hexabromocyclododecane (HBCDD) is considered as a priority for risk evaluation and substance restriction.. Phthalate. Test Method :. Determination of phthalates by GC-MS based on EN 14372:2004.. Test Item(s). Dibutyl Phthalate (DBP). Benzylbutyl Phthalate (BBP). Bis-(2-ethylhexyl) Phthalate (DEHP). Unit. MDL. 003. % (w/w). % (w/w). % (w/w). 0.003 0.003 0.003 ND ND ND Notes :. (1) Reference Information: Directive 2011/65/EU recasting RoHS directive 2002/95/EC: Bis (2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP) and Dibutyl phthalate (DBP) are considered as a priority for risk evaluation and substance restriction.. Test Report. No. CANEC1305766701 Date: 28 Apr 2013. Page 5 of 9. ATTACHMENTS RoHS Testing Flow Chart 1) Name of the person who made testing: Michael Tso / Cutey Yu 2) Name of the person in charge of testing: Adams Yu / Yolanda Wei 3) These samples were dissolved totally by pre-conditioning method according to below flow chart (Cr6+ and PBBs/PBDEs test method excluded). Sample Preparation Sample Measurement Pb/Cd/Hg Acid digestion with microwave/ hotplate Sample solvent extraction Filtration Concentration/ Dilution of extraction solution Solution Residue Filtration 1) Alkali Fusion / Dry Ashing 2) Acid to dissolve ICP-OES/AAS DATA Cr6+ PBBs/PBDEs GC-MS DATA Nonmetallic material Adding digestion reagent Heating to 90~95℃ for extraction Filtration and pH adjustment Adding 1,5diphenylcarbazide for color development Metallic material Positive Spot test Negative Boiling water extraction Adding 1,5diphenylcarbazide for color development UV-Vis A red color indicates the presence of Cr6+. If necessary, confirm with UV-Vis. DATA DATA Test Report. No. CANEC1305766701 ATTACHMENTS Phthalates Testing Flow Chart 1) Name of the person who made testing: Liu Qiong 2) Name of the person in charge of testing: Yolanda Wei Sample cutting / preparation Sample Measurement Solvent extraction Concentration/Dilution Filtration GC-MS DATA Date: 28 Apr 2013. Page 6 of 9. Test Report. No. CANEC1305766701 ATTACHMENTS HBCDD Testing Flow Chart 1) Name of the person who made testing: Cutey Yu 2) Name of the person in charge of testing: Yolanda Wei Sample cutting / preparation Sample Measurement Solvent extraction Concentration/Dilution Filtration GC-MS DATA Date: 28 Apr 2013. Page 7 of 9. Test Report. No. CANEC1305766701 Sample photo:. CANEC1305766701 CAN13-057667.001. CANEC1305766701 CAN13-057667.002. Date: 28 Apr 2013. Page 8 of 9. Test Report. No. CANEC1305766701 Date: 28 Apr 2013. CANEC1305766701 CAN13-057667.003. SGS authenticate the photo on original report only. *** End of Report ***. Page 9 of 9.